88.12.0.230.0002 FINDER, 88.12.0.230.0002 Datasheet - Page 4

MULTIFUNCTION TIMER

88.12.0.230.0002

Manufacturer Part Number
88.12.0.230.0002
Description
MULTIFUNCTION TIMER
Manufacturer
FINDER
Datasheet

Specifications of 88.12.0.230.0002

Contact Configuration
DPDT
Nom Input Voltage
230V
Delay Time Range
0.05s To 100h
Adjustment Type
Knob
Relay Mounting
Panel
Svhc
No SVHC (15-Dec-2010)
Contact Current Ac Max
5A
Contact Voltage Ac Max
250V
Contact Type
2 CO (SPDT)
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Functions
Wiring diagram
without signal START
4
N/–
A1 A2 12 11 14 22 21 24
2 7 4
U
L/+
C
1
1
3 5 8 6
C
2
Type 88.12
U
U
U
C
C
U
C
C
C
C
U
U
C
C
C
C
C
C
1
2
1
2
1
2
1
2
1
2
1
2
T
T
T
T
T
T
T
T
0.5s
T
t<T
(GI)
Apply power to timer. Output contacts transfer after preset time
has elapsed. Reset occurs after a fixed time of 0.5s.
(SW)
Apply power to timer. Output contacts transfer immediately
and cycle between ON and OFF for as long as power is applied.
The ratio is 1:1 (time on = time off).
(Al a)
Apply power to timer.
Contacts (C
Reset occurs when power is removed.
(Al b)
Apply power to timer. Output contact (C
Contact (C
occurs when power is removed.
(Dl a)
Apply power to timer.
Output contacts (C
After preset time has elasped, the contacts reset.
(Dl b)
Apply powert to timer. Output contacts (C
immediately. After preset time has elasped, the contact (C
resets. Contact (C
88 Series - Plug-in timers 5 - 8 A
Fixed pulse (0.5s) delayed.
Symmetrical recycling.
ON pulse (2 timed contacts).
ON pulse (1 timed contact + 1 instantaneous contact).
ON Delay (2 timed contacts).
ON Delay
(1 timed contact + 1 instantaneous contact).
2
1
) transfers after the preset time has elasped. Reset
and C
1
1
) resets when power is removed.
2
and C
) transfer after preset time has elasped.
2
) transfer immediately.
1
) transfers immediately.
1
and C
2
) transfer
2
)