G2ZIF20 24-240V TELE, G2ZIF20 24-240V Datasheet

TIMER, MULTIFUNCTION-7, 2 CO

G2ZIF20 24-240V

Manufacturer Part Number
G2ZIF20 24-240V
Description
TIMER, MULTIFUNCTION-7, 2 CO
Manufacturer
TELE
Datasheet

Specifications of G2ZIF20 24-240V

Contact Configuration
DPCO
Nom Input Voltage
240V
Delay Time Range
50ms To 10h
Adjustment Type
Screwdriver Slot
Relay Mounting
DIN Rail
Svhc
No SVHC (18-Jun-2010)
Coil Voltage Vac Nom
250V
Contact
RoHS Compliant
GAMMA series
7 functions
10 time ranges
Connection of remote potentiometer possible
Zoom voltage 24 to 240V AC/DC
2 change-over contacts
Width 22.5mm
Industrial design
Technical data
1. Functions
2. Time ranges
Time range
3. Indicators
Green LED U/t1 ON:
Green LED U/t1 flashes: indication of time period t1
Green LED t2 flashes:
Yellow LED ON/OFF:
4. Mechanical design
Self-extinguishing plastic housing, IP rating IP40
Mounted on DIN-Rail TS 35 according to EN 60715
Mounting position: any
Shockproof terminal connection according to VBG 4
(PZ1 required), IP rating IP20
Tightening torque: max. 1Nm
Terminal capacity:
5. Input circuit
Supply voltage:
Tolerance:
Rated frequency:
Rated consumption:
Duration of operation:
Reset time:
Wave form for AC:
Residual ripple for DC:
Drop-out voltage:
Overvoltage category:
Ip
Ii
ER
EWu
EWs
WsWa Single shot leading and single shot trailling edge
1s
3s
10s
30s
1min
3min
10min
30min
1h
10h
1 x 0.5 to 2.5mm² with/without multicore cable end
1 x 4mm² without multicore cable end
2 x 0.5 to 1.5mm² with/without multicore cable end
2 x 2.5mm² flexible without multicore cable end
24 to 240V AC/DC
24 to 240V DC
24 to 240V AC
24 to 240V AC
48 to 240V AC
Timers - Multifunction7 functions
Asymmetric flasher pause first
Asymmetric flasher pulse first
ON delay and OFF delay with control input
ON delay and single shot leading edge with control input
ON delay single shot leading edge voltage controlled
with control contact
Adjustment range
50ms
150ms
500ms
1500ms
3s
9s
30s
90s
3min
30min
indication of supply voltage
indication of time period t2
indication of relay output
1s
3s
10s
30s
1min
3min
10min
30min
1h
10h
terminals A1-A2 (galvanically separated)
-20% to +25%
-15% to +10%
48 to 400Hz
16 to 48Hz
4.5VA (1W)
100%
500ms
Sinus
10%
>15% of the supply voltage
III (in accordance with IEC 60661-1)
www.tele-online.com
Rated surge voltage:
6. Output circuit
2 potential free change over contacts
Rated voltage:
Switching capacity:
If the distance between the devices is less than 5mm!
Switching capacity:
If the distance between the devices is greater than 5mm!
Fusing:
Mechanical life:
Electrical Life:
Switching frequency:
Overvoltage category:
Rated surge voltage:
7. Control contact
Activation:
Potential free:
Loadable:
Control voltage:
Short circuit current:
Line length:
Control pulse length:
8. Remote potentiometer (not included)
The internal potentiometer is de-activated when a remote potentio-meter
is connected !!!
Connections:
Line type:
Control voltage:
Short circuit current:
Line length:
9. Accuracy
Base accuracy:
Frequency response:
Adjustment accuracy:
Repetition accuracy:
4kV
250V AC
750VA (3A / 250V AC)
1250VA (5A / 250V AC)
5A fast acting
20 x 10
2 x 10
max. 60/min at 100VA resistive load
max. 6/min at 1000VA resistive load
(in accordance with IEC 60947-5-1)
III (in accordance with IEC 60664-1)
4kV
bridge Y1-Y2
yes, basic isolation against input and
output circuit
no
max. 5V
max. 1mA
max. 10m
min. 50ms (except Wt function)
min. 7ms (Wt function only)
1MΩ potentiometer (type RONDO R2),
terminals Y2-Z1 resp. Y2-Z2
twisted pair
max. 5V
max. 5μA
max. 5m
±1% (of maximum scale value)
using 1MΩ remote potentiometer
-
≤5% (of maximum scale value)
using 1MΩ remote potentiometer
<0.5% or ±5ms
5
6
operations at 1000VA resistive load
operations
G2ZIF20 24-240V

Related parts for G2ZIF20 24-240V

G2ZIF20 24-240V Summary of contents

Page 1

... Frequency response: Adjustment accuracy: Repetition accuracy: www.tele-online.com G2ZIF20 24-240V 4kV 250V AC 750VA (3A / 250V AC) 1250VA (5A / 250V AC) 5A fast acting operations operations at 1000VA resistive load 5 max. 60/min at 100VA resistive load max. 6/min at 1000VA resistive load (in accordance with IEC 60947-5-1) III (in accordance with IEC 60664-1) ...

Page 2

... LED not illuminated). During the interval, the control contact can be operated any number of times. A further cycle can only be started when the cycle run has been completed www.tele-online.com G2ZIF20 24-240V U LED U/t1 LED t2 Y1-Y2 LED R/R 15-16-18 R 25-26-28 ...

Page 3

... All further pulses at the control contact are ignored. To restart the function the supply voltage must be interrupted and re-applied. U LED U/t1 LED t2 Y1-Y2 LED R/R 15-16-18 R 25-26-28 t1 <t2 <t2 =t2 RELEASE 2009/07 Subject to alterations and errors Connections t2 Dimensions >t2 www.tele-online.com G2ZIF20 24-240V ...

Related keywords