A1384LLHLT-T Allegro Microsystems Inc, A1384LLHLT-T Datasheet - Page 14

IC SENSOR HALL EFFECT SOT23-W

A1384LLHLT-T

Manufacturer Part Number
A1384LLHLT-T
Description
IC SENSOR HALL EFFECT SOT23-W
Manufacturer
Allegro Microsystems Inc
Series
A138xr
Type
Linear - Programmabler
Datasheet

Specifications of A1384LLHLT-T

Sensing Range
2mV/G ~ 3mV/G
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
8mA
Current - Output (max)
10mA
Output Type
Analog, Ratiometric
Operating Temperature
-40°C ~ 150°C
Package / Case
SOT-23W
Peak Reflow Compatible (260 C)
Yes
Accuracy %
1.5%
Supply Voltage
5V
Output Current
2mA
Termination Type
SMD
Bandwidth
27kHz
Supply Voltage Max
5.5V
Sensitivity
2 To 3 MV/G
Leaded Process Compatible
Yes
No. Of Pins
3
Hall Effect Type
Linear
Supply Voltage Min
4.5V
Operating Temperature Max
150°C
Rohs Compliant
Yes
Filter Terminals
SMD
Operating Temperature Min
-40°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
620-1199-2
A1381, A1382,
A1383, and A1384
Try Mode
Try mode allows a single programmable parameter to be tested
without permanently setting its value. Multiple parameters cannot
be tested simultaneously in this mode. After powering the VCC
supply, select the desired parameter register and address its bit
field. When addressing the bit field, each V
the value of the parameter register, up to the maximum possible
code (see Programming Logic table). The addressed parameter
value remains stored in the device even after the programming
drive voltage is removed from the VOUT pin, allowing the value
to be measured. Note that for accurate time measurements, the
blow capacitor, C
measurement.
It is not possible to decrement the value of the register without
resetting the parameter bit field. To reset the bit field, and thus the
value of the programmable parameter, cycle the supply (V
BLOW
, should be removed during output voltage
Programmable Linear Hall Effect Sensor ICs with Analog Output
Available in a Miniature Thin Profile Surface Mount Package
PM
pulse increments
Programming Modes
CC
) voltage.
Blow Mode
After the required value of the programmable parameter is found
using Try mode, its corresponding code should be blown to make
its value permanent. To do this, select the required parameter
register, and address and blow each required bit separately (as
described in the Fuse Blowing section). The supply must be
cycled between blowing each bit of a given code. After a bit is
blown, cycling the supply will not reset its value.
Lock Mode
To lock the device, address the LOCK bit and apply a blow pulse
with C
gramming of any parameter is possible.
BLOW
in place. After locking the device, no future pro-
115 Northeast Cutoff, Box 15036
Allegro MicroSystems, Inc.
Worcester, Massachusetts 01615-0036 (508) 853-5000
www.allegromicro.com
14