4AV19F Honeywell Sensing and Control, 4AV19F Datasheet

SENSOR MAGN HALL EFFECT VANE

4AV19F

Manufacturer Part Number
4AV19F
Description
SENSOR MAGN HALL EFFECT VANE
Manufacturer
Honeywell Sensing and Control
Datasheet

Specifications of 4AV19F

Output Voltage Min
400mV
Output Configuration
Sink
Switching Speed
1.5µs
Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Installation Instructions for the
4AV Series Vane Sensors
PERSONAL INJURY
DO NOT USE these products as safety or
emergency stop devices or in any other application
where failure of the product could result in personal
injury.
Failure to comply with these instructions could
result in death or serious injury.
ELECTRICAL CHARACTERISTICS
VANE DIMENSIONS (mm/in)
Sensing and Control
Thickness
1,0/0.4
1,6/.06
4AV20F-T1*
4AV20F-T2**
*Will mate with AMP Connector Housing 87499-8, not supplied
**Will mate with Molex Connector Housing 2695/6471, not supplied
Catalog
4AV15F
4AV16F
4AV17F
4AV18F
4AV19F
4AV20F
Listing
Min.
Window
10,2/.40
10,2/.40
.015 X .025 PCB
24 AWG Wire
24 AWG Wire
24 AWG Wire
24 AWG Wire
24 AWG Wire
Termination
.025 X .025
.025 X .025
Connector
Connector
Min.
Tooth
10,2/.40
6,3/.25
Block 22-05-3041
Block 103323-4
Molex Terminal
AMP Terminal
13.15
18.15
22.00
5.50
7.45
Length
0.140
Lead
0.25
0.25
0.50
0.50
0.50
Min. Tooth
Depth
9,27/.365
9,27/.365
All Listings
26.5 VDC
4.5 VDC
Voltage
Supply
through
GENERAL INFORMATION
sensor and a magnet in a common package. They
are operated by passing a ferrous vane through the
gap between the magnet and the sensor.
(conducting). With the vane in the gap, the output is
Released (non-conducting). The vane actuator is
annealed low carbon cold rolled steel, type AISI
1018 or lower in carbon. Minimum recommended
vane dimensions are required to ensure operating
characteristics will be met.
15.25 mA typical
18.5 mA Max
All Listings
4AV Hall effect vane sensors include a Hall effect
With no vane in the gap, the output is Operated
@ -40 C
11.75 mA
Current
@25 C
Supply
typical
@25 C typical
All listings
0.4 V Max
0.1 typical
@125 C
Voltage
0.075 V
Output
PK 87605
to reach total.
Sink Current
sink currents
are summed
Dual output
All listings
40 mA Max
Output
ISSUE 2

Related parts for 4AV19F

4AV19F Summary of contents

Page 1

... Listing Length 4AV15F 24 AWG Wire 5.50 4AV16F 24 AWG Wire 7.45 4AV17F 24 AWG Wire 13.15 4AV18F 24 AWG Wire 18.15 4AV19F 24 AWG Wire 22.00 4AV20F .015 X .025 PCB 0.140 4AV20F-T1* .025 X .025 AMP Terminal Connector Block 103323-4 4AV20F-T2** .025 X .025 Molex Terminal Connector ...

Page 2

... CAUTION PRODUCT DAMAGE Do not exceed electrical specifications. Do not mis-wire the output connection. Do not reverse supply voltage polarity. Handle terminals with care. Failure to comply with these instructions may result in product damage. 2 Honeywell Sensing and Control Right Right Right L-R Operate Release Diff Diff ...

Page 3

... CAUTION PRODUCT DAMAGE Ensure cleaner does not come in contact with sensor If other cleaning methods are selected for removal of flux residue. Failure to comply with these instructions may result in product damage. Honeywell Sensing and Control 3 PK 87605 ...

Page 4

Series Vane Sensors EXAMPLE WIRING DIAGRAMS WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the ...