4AV19F Honeywell Sensing and Control, 4AV19F Datasheet - Page 3

SENSOR MAGN HALL EFFECT VANE

4AV19F

Manufacturer Part Number
4AV19F
Description
SENSOR MAGN HALL EFFECT VANE
Manufacturer
Honeywell Sensing and Control
Datasheet

Specifications of 4AV19F

Output Voltage Min
400mV
Output Configuration
Sink
Switching Speed
1.5µs
Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Wave Soldering
4AV Series Vane Sensors
SOLDERING
CAUTION
PRODUCT DAMAGE
Failure to comply with these instructions may result in
product damage.
Hand Soldering
1. Flux: Rosin Base
2. Solder: Kester #44 60-40 rosin core, or
3. Soldering Iron: Type; Weller, Model TC-552, 55
4. Tip Size: 3mm (.118 in.) Diameter x 30mm
5. Tip Temperature: 288 C (550 F) max
6. Terminal Contact Time: 6 seconds max.
1. Flux: London Chemical Co. Loncoflux - 106A35
2. Preheat: Preheaters should be set to give 95 C
3. Solder Temperature: 260 C (500 F) max.;
4. Speed: Set conveyor speed to approximately
5. Printed circuit board requires rigid support
For application help: call 1-800-537-6945
The following is recommended:
The following is recommended:
Ensure iron tip is clean when soldering.
equivalent.
watt or equivalent.
(1.182 in.) long
or equivalent
(200 F) on the top (component side) of printed
circuit board just prior to board entering the
wave. (May have to be adjusted depending
upon board thickness.)
preferably 252 C to 260 C (485 F to 500 F).
4.5 feet/minute (1,37 meters/minute).
during wave soldering.
CLEANING
Hand Cleaning
alcohol and clean tap water. Dry in a 71 C (160 F)
oven for 10-15 minutes, preferably in a non-
circulating oven. This will remove all moisture from
the assembly, which must be done before electrical
testing, or application.
Machine Cleaning *
Loncoterge 444-NRT6 or equivalent. Equipment:
Dee Electric Aqueous Cleaner or equivalent. The
following is reccommended:
1. Wash Section: 55 C (130 F) maximum water
2. Rinse Section #1: Clean tap water up to 25
3. Rinse Section #2: Clean deionized water only,
4. Air Knife Section: To remove excessive amounts
5. Drying Section: 71 C (160 F) drying for 10-15
* In this cleaning system, the detergent in the wash
section removes the non-polar contaminants, the first rinse
removes the detergent solution, and the deionized water
rinse removes the polar contaminants. The air knife and
dryer remove all the moisture from the assembly, which
must be done before electrical testing or application.
CAUTION
PRODUCT DAMAGE
Failure to comply with these instructions may result in
product damage.
Ensure cleaner does not come in contact with sensor If
other cleaning methods are selected for removal of flux
residue.
Clean areas with a 50-50 mixture of isopropyl
Detergent: London Chemical Company
temperature, 5 to 10% maximum solution soft
water, low pressure nozzles (60 psi) on top
spray and high pressure nozzles (120 psi) on
bottom spray, conveyor speed 3 feet/minute
minimum. Recirculating tank.
grains hard, salt free (to minimize possibility of
corrosion), unheated, non-recirculating, with
high pressure nozzles (120 psi).
high pressure nozzles (120 psi), unheated and
non-recirculating.
of water.
minutes, preferably in a non-circulating conveyor
oven.
Honeywell Sensing and Control 3
ISSUE 2
PK 87605