XA1E-BV413-RH-EMO IDEC, XA1E-BV413-RH-EMO Datasheet - Page 2

SWITCH, EMERGENCY STOP, 3NC/1NO, 250VAC

XA1E-BV413-RH-EMO

Manufacturer Part Number
XA1E-BV413-RH-EMO
Description
SWITCH, EMERGENCY STOP, 3NC/1NO, 250VAC
Manufacturer
IDEC
Datasheet

Specifications of XA1E-BV413-RH-EMO

Contact Configuration
4PST-3NC / 1NO
Switch Operation
Pushlock Turn Reset
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
250V
Contact Current Max
3A
Actuator Style
Mushroom
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
2
ø16mm XA Series / ø22mm XW Series
SEMI Emergency Off (EMO) Switches
XA and XW series
emergency stop switches are
now available with EMO
markings. When used in
combination with switch
guards ensures compliance
to SEMI S2 standards.
< Structure and Features >
Detaching the Contact Block
When the contact block is detached from the operator, the cam directly
opens the NC main contacts (contacts are off).
All normally closed contact elements of an emergency stop devices shall have
a direct opening action (positive opening action), according to annex K of
IEC 60947-5-1. (IEC 60947-5-5; 5.2)
Achievement of contact separation (of a contact element) of the switch actuator
through non-resilient members (for example not dependent upon springs) (IEC
60947-5-1; Annex K)
The emergency stop signal shall be maintained until the emergency stop device
is reset (disengaged). (IEC 60947-5-5; 6.2)
World's
World's
World's
World's
First
First
First
First
Safe Break Action
Direct Opening Action
Safety Lock Mechanism
ø
Operator
Contact
Block
16mm XA Series
New
When the contact block is detached from the
operator, the NC contact opens (OFF).
• Up to four contacts
• Only 27.9 mm deep behind the
panel for any number of contacts
Closed ON
1
27
mm
.9
2
3
Open (OFF)
4
Shortest
Shortest
With the XA and XW emergency stop switches, the potential energy level of the
latched status is lower than that of the normal status. In the event the contact block is
damaged due to excessive shocks, the NC contacts will turn off, thus leading to safety
by stopping the machine.
World's
World's
Normal Status
Normal Status
ø
Safety Potential Structure
22mm XW Series
• Shortest for four-contact type
• Only 48.7 mm deep behind
the panel for any number of
contacts, reducing space.
2nd-generation
NC
contacts:
ON
(machine
can
operate)
NC contacts:
ON (machine
can operate)
Latched
Latched
48
NC contacts:
OFF
(machine
cannot
operate)
mm
.7
Normal Status
Normal Status
operate)
NC contacts: OFF
(machine cannot
(Safety Potential Structure)
3rd-generation
NC
contacts:
ON
(machine
can operate)
Latched
Latched
NC
contacts:
OFF
(machine
cannot
operate)

Related parts for XA1E-BV413-RH-EMO