PNOZ X2.8 .. 777302 PILZ, PNOZ X2.8 .. 777302 Datasheet

SAFETY RELAY, 3NO 24VAC

PNOZ X2.8 .. 777302

Manufacturer Part Number
PNOZ X2.8 .. 777302
Description
SAFETY RELAY, 3NO 24VAC
Manufacturer
PILZ
Datasheet

Specifications of PNOZ X2.8 .. 777302

Coil Voltage Vac Nom
24V
Contact Current Max
6A
Contact Voltage Dc Nom
24V
No. Of Poles
3
Relay Mounting
DIN Rail
External Width
90mm
External Depth
110mm
Svhc
No SVHC (18-Jun-2010)
Approval Bodies
BS
PNOZ
Safety Relays
®
Safety relays PNOZ X, PNOZsigma and PNOZelog,
Modular safety relays PNOZmulti and PNOZpower
The optimum safety solution for every requirement.

Related parts for PNOZ X2.8 .. 777302

PNOZ X2.8 .. 777302 Summary of contents

Page 1

PNOZ Safety Relays ® Safety relays PNOZ X, PNOZsigma and PNOZelog, Modular safety relays PNOZmulti and PNOZpower The optimum safety solution for every requirement. ...

Page 2

... Support Technical help round the clock! Technical support is available from Pilz round the clock. This service is provided free of charge beyond standard business hours. Americas • Brazil +55 11 8245-8267 • Mexico +52 55 5572 1300 • USA (toll-free) +1 877-PILZUSA (745-9872) Asia • China +86 21 62494658-216 • ...

Page 3

... Training • • Safety switches Secure safety gate systems Optoelectronic protective devices Safe camera systems Electronic monitoring relays Safety relays Programmable safety and control systems Industrial communication Control systems Servo amplifi ers ...

Page 4

... Pilz is a family business that's closer to its customers. Pilz has a tradition as a family-run company stretching back over 50 years. Real proximity to customers is visible in all areas, instilling confi dence through individual consultation, fl ...

Page 5

... PNOZ safety relays Pilz is world numerous applications. Our market leader. current product portfolio includes the following product ranges: Synonym for safety • PNOZ X In 1987 Pilz developed the fi rst • PNOZsigma emergency stop relay to protect • PNOZelog man and machine. That was a • ...

Page 6

... Pilz can offer a universal concept for solutions that can be applied right across industry – safety-related or standard control functions – plant or machine – centralised or decentralised – single product or total solution: With Pilz you will defi nitely fi solution for your automation function. Sensor technology 4 ...

Page 7

... PMDsrange monitoring relays provide the optimum solution cover safety func- • Pilz Motion Control (PMC) represents a fl exible, modular and expandable automation system for complex motion - On complex machinery or and control functions. This automation system manages ...

Page 8

PMDsrange electronic monitoring relays Taking control of every situation Reliable, electronic monitoring and control of plant and machinery are the primary focus for our monitoring relays. The units in 22.5 mm slimline housing cover different functions. Electronic ...

Page 9

Technical details PMDsrange The PMDsrange ensures years of trouble-free operation for your machine. S1EN S1WP Insulation and fault voltage True power monitoring and conversion, monitoring of AC/DC supplies, DC supplies and single/three phase AC single and three-phase supplies, relay and ...

Page 10

PNOZ safety relays ® The optimum safety solution for each application! For us, safety is more than just a product. Safe con trol technology is based on experi ence and innovation. PNOZ X PNOZpower PNOZmulti CHIP-Card PNOZ ...

Page 11

Finding your PNOZ This diagram will help you choose. You have specifi c require- ments, we have the right solution – the PNOZ product group! More than 4 safety functions? Yes No Volt-free outputs loads? PNOZelog Further information ...

Page 12

... Pilz. PNOZ safety relays – Certifi ed worldwide When using PNOZ safety relays, the aim is to keep the risk to man and machine as low as pos- sible ...

Page 13

... DIN ISO 9001 e • Use of products that are geared towards the future, thank to innovative developments • Complete solution comprising evaluation devices, compatible sensor technology and control and signal devices Find out more about the standards: Webcode 0240 Online information at www.pilz.com 11 ...

Page 14

PNOZ X safety relays Customised safety for each application Safety relays from the PNOZ X product range are proven through their reliability and robustness and have developed a wide appli- cation range in the most varied of safety applications. PNOZ ...

Page 15

... Maximum safety with mini- mum space requirement • Complete solution comprising evaluation devices, compatible sensor technology and control and signal devices • Low storage costs thanks to universal power supply and plug-in terminals PNOZ X2P Keep up-to-date on PNOZ X safety relays: Webcode 0210 Online information at www.pilz.com 13 ...

Page 16

Selection guide – PNOZ X Compact, electromechanical safety relays – PNOZ X Type Application ◆ ◆ PNOZ X1P ◆ ◆ PNOZ X2P ◆ ◆ PNOZ X2.7P ◆ ◆ PNOZ X2.8P ◆ ◆ PNOZ X3P ◆ ◆ PNOZ X7P ◆ ◆ ...

Page 17

... Level PL Level SIL CL (EN ISO 13849-1) (claim limit in accordance with IEC 62061 Output contacts Safe Non-safe Output contacts Safe Non-safe Housing width in mm 22.5 22.5 22.5 22 22.5 45 Technical documentation on PNOZ X safety relays: Webcode 0685 Housing width Online information www.pilz.com 22 ...

Page 18

Technical details – PNOZ X Compact, electromechanical safety relays – PNOZ X Type PNOZ X1P PNOZ X2P PNOZ X1P PNOZ X2.7P PNOZ X2.8P PNOZ X3P PNOZ X2.7P PNOZ X7P PNOZ X3P PNOZ X8P 16 Supply voltage Outputs: Voltage/current/ rating 24 ...

Page 19

... More available on request More available on request 24 VAC ............................... 787 770 24 VAC ............................... 777 770 24 VDC ............................... 787 760 24 VDC ............................... 777 760 More available on request More available on request 1) Height with cage clamp terminals/plug-in screw terminals Technical documentation on PNOZ X safety relays: Webcode 0685 Online information at www.pilz.com 17 ...

Page 20

Technical details – PNOZ X Compact, electromechanical safety relays – PNOZ X Type PNOZ X9P PNOZ X9P PNOZ X11P PNOZ XV1P PNOZ XV1P PNOZ XV3P PNOZ XV3.1P PNOZ XV3P 18 Supply voltage Outputs: Voltage/current/ rating 24 VDC DC1: 24 V/8 ...

Page 21

... VAC/DC ............. 777 532 30 s selectable selectable, 24 … 240 VAC/DC ............. 787 530 24 … 240 VAC/DC ............. 777 530 More available on request More available on request 1) Height with cage clamp terminals/plug-in screw terminals Technical documentation on PNOZ X safety relays: Webcode 0685 Online information at www.pilz.com 19 ...

Page 22

Technical details – PNOZ X Compact, electromechanical safety relays – PNOZ X Type PMUT X1P PMUT X1P P2HZ X1P P2HZ X4P PSWZ X1P PSWZ X1P PZE X4P PZE X4P PZE 9P 20 Supply voltage Outputs: Voltage/current/ rating 24 VDC DC1: ...

Page 23

... V ................................ 777 950 M M 787 585 777 585 24 VAC/DC ......................... 787 140 24 VAC/DC ......................... 777 140 100 … 240 VAC .................. 787 148 100 … 240 VAC .................. 777 148 1) Height with cage clamp terminals/plug-in screw terminals Technical documentation on PNOZ X safety relays: Webcode 0685 Online information at www.pilz.com 21 ...

Page 24

Compact safety relays PNOZsigma Maximum functionality in minimum width The new compact safety relays PNOZsigma combine many years of experience with today's very latest safety technology: you can achieve maximum safety and cost-effectiveness with minimum effort. All round effi ciency ...

Page 25

... Selectable operating modes and timers enable each unit to be fl exible in its application • A single unit type monitors different safety functions • Your stockholding can be reduced to a few unit types Keep up-to-date on PNOZsigma safety relays: Online information at www.pilz.com 23 Webcode 0994 ...

Page 26

The sum of our experience – PNOZsigma Selectable operating modes for maximum fl exibility • Selectable reset modes: manual reset, automatic reset, monitored reset or reset with start-up test • Selectable operating mode: With or without detection of shorts across ...

Page 27

Wiring reduced by 20%: Contact expansion via connectors Rapid installation: new – innovative spring-loaded terminals, chambers operated individually Maximum fl exibility: Selectable operating modes and timer functions Diagnostics in seconds: via 6 LEDs – no external ...

Page 28

Selection guide – PNOZsigma Compact safety relays – PNOZsigma Type Application ◆ ◆ PNOZ s1 ◆ ◆ PNOZ s2 ◆ ◆ PNOZ s3 ◆ ◆ PNOZ s4 ◆ ◆ PNOZ s5 PNOZ s6 PNOZ s6.1 PNOZ s7 Contact expansion PNOZ ...

Page 29

... SIL3 Depends base unit Universal power supply Auxiliary contacts 48 … 240 VAC/ ◆ ◆ ◆ ◆ Housing width in mm 12.5 17.5 17.5 22.5 22.5 22.5 22.5 17.5 12.5 17.5 45.0 Technical documentation on PNOZsigma safety relays: Webcode 0685 Online information at www.pilz.com 27 ...

Page 30

Technical details – PNOZsigma Compact safety relays – PNOZsigma Type PNOZ s1 PNOZ s2 PNOZ s1 PNOZ s3 PNOZ s4 PNOZ s3 PNOZ s5 PNOZ s5 PNOZ s6 PNOZ s6.1 PNOZ s7 PNOZ s8 PNOZ s10 PNOZ s9 PNOZ s10 ...

Page 31

... VAC/DC ...........751 156 48 … 240 VAC/DC ...........750 156 24 VDC ............................751 107 24 VDC ............................750 107 24 VDC ............................751 108 24 VDC ............................750 108 24 VDC ............................751 109 24 VDC ............................750 109 24 VDC ............................751 110 24 VDC ............................750 110 Technical documentation on PNOZsigma safety relays: Webcode 0685 Online information at www.pilz.com 29 ...

Page 32

PNOZelog electronic safety relays Extended diagnostics, easy to link Ideal for monitoring up to four safety functions, the innovative PNOZelog product range com- bines the experience of the electromechanical safety relays with the benefi modern electronics. Wear-resistance, safety, ...

Page 33

... Complete solution comprising evaluation devices, compatible sensor technology and control and signal devices Keep up-to-date on PNOZelog safety relays: Online information at www.pilz.com PNOZelog now available with volt-free relay outputs! 31 Webcode 0209 ...

Page 34

PNOZelog electronic safety relays Fewer downtimes thanks to extended diagnostics. Easy-to-use diagnostics make the unit cost-effective PNOZelog has extensive diagnostic options: • Simple LED indicators and status output enable the easiest possible on-site diagnostics, without additional tools. • Integral diagnostic ...

Page 35

AND operation. Each safety function has a separate signal output. • PNOZ e5.11p simultaneously monitors an E-STOP/safety gate combination or two safety gates • The PNOZ e5.13p can also be connected to the PSENmag ...

Page 36

Selection guide – PNOZelog Compact, electronic safety relays – PNOZelog Type Application ◆ ◆ PNOZ e1p ◆ ◆ PNOZ e1.1p ◆ ◆ PNOZ e1vp PNOZ e2.1p PNOZ e2.2p ◆ PNOZ e3.1p ◆ PNOZ e3vp PNOZ e4.1p PNOZ e4vp ◆ ◆ ...

Page 37

... Logic operations - ◆ ◆ - ◆ ◆ - ◆ ◆ - ◆ ◆ - ◆ ◆ - ◆ ◆ - ◆ ◆ - ◆ ◆ - ◆ ◆ ◆ ◆ - ◆ ◆ Also AND-linked internally Technical documentation on PNOZelog safety relays: Webcode 0685 Online information at ww.pilz.com 35 ...

Page 38

Technical details – PNOZelog Compact, electronic safety relays – PNOZelog Type PNOZ e1p PNOZ e1.1p PNOZ e1.1p PNOZ e1vp PNOZ e2.1p PNOZ e2.1p PNOZ e2.2p PNOZ e3.1p PNOZ e3.1p PNOZ e3vp Common features • Supply voltage (U 36 • Dimensions ...

Page 39

... PNOZ e2.2p ..... 784 135 • PNOZ e2.2p ..... 774 135 784 139 774 139 10 s .................... 784 137 10 s .................... 774 137 300 s .................... 784 138 300 s .................... 774 138 1) Height with cage clamp terminals/plug-in screw terminals Technical documentation on PNOZelog safety relays: Webcode 0685 Online information at ww.pilz.com 37 ...

Page 40

Technical details – PNOZelog Compact, electronic safety relays – PNOZelog Type PNOZ e4.1p PNOZ e4vp PNOZ e4.1p PNOZ e5.11p PNOZ e5.11p PNOZ e5.13p PNOZ e6.1p PNOZ e6.1p PNOZ e6vp Common features • Supply voltage (U • Dimensions ( ...

Page 41

... Height with cage clamp terminals/plug-in screw terminals Technical documentation on PNOZelog safety relays: Webcode 0685 Online information at ww.pilz.com 39 ...

Page 42

Modular safety system PNOZmulti Ingeniously simple, simply ingenious The modular safety system PNOZmulti is multifunctional, freely confi gurable and tailor- made for use in many areas of mechanical engineering. Safety functions such as emer- gency stop, safety gates, light beam ...

Page 43

... Approved press blocks, muting functionalities and many other features make the PNOZmulti as simple to use as a PNOZ and as fl exible as a controller. Keep up-to-date on modular safety systems PNOZmulti: Online information at www.pilz.com Example: using the PNOZmulti modular safety system on a packaging machine. 41 Webcode 0243 ...

Page 44

Customised application and child’s play to PNOZmulti Confi gurator Your safety circuit is easy to confi gure on the PC using the PNOZmulti Confi gurator. The graphics-based user interface conforms to the Windows ® standard; all elements are available either ...

Page 45

Example of a time delay element with a delay time of 600 ms (selectable). Example of a semi- conductor output in accordance with Category 4, EN 954-1, without feedback loop. ...

Page 46

Modular and fl exible Your benefi glance • At least 40 % potential savings in all engineering phases thanks to a freely confi gurable graphics confi guration tool • Ideal for covering appli- cations of four safety ...

Page 47

Applications and industries PNOZmulti Safe and economical Application areas may include: in all industries • General mechanical PNOZmulti is used in numerous engineering, e.g. lathes, applications across the widest milling and drilling machines range of industries. The intelli- • Plastics ...

Page 48

The basis for each application: many func Base unit PNOZ m0p – the compact solution … … for machines on which three to six safety functions are moni- tored. PNOZmulti is economical from just three functions. Your costs are even ...

Page 49

CHIP-Card PNOZ m1p Adapted to extreme environmental conditions. PNOZ m2p – Withstands plenty … … and is specially designed to control and monitor small and average-sized eccentric and hydraulic ...

Page 50

... The PNOZmulti Webcode 1046 Confi gurator contains the Online information at www.pilz.com 1) PNOZ m1p base unit from Version 5, PNOZ m0p and PNOZ m2p base units from Version 2, PNOZmulti Confi gurator from Version 5.0.0 ...

Page 51

Effective symbiosis of safety and standard Perform your automation functions more economically! PNOZmulti offers a selection of functionalities with which to monitor safety-related and standard control functions: • The connection module PNOZ ml1p for safe connection of two PNOZmulti base ...

Page 52

Selection guide – PNOZmulti Modular safety system – PNOZmulti Type Application area PNOZ mi1p Safe input module PNOZ mi2p Input module PNOZ mo1p Safe semiconductor output module PNOZ mo3p 2-pole, safe semiconductor output module PNOZ mo2p Safe relay output module ...

Page 53

... All base units have Performance Level e and Safety Integrity Level 3. PNOZ m2p (press applications) ≥ 4 Safety functions ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ Technical ◆ documentation ◆ on PNOZmulti modular safety ◆ sys tems: ◆ Webcode 0685 Online information at www.pilz.com 51 ...

Page 54

Technical details – PNOZmulti Modular safety system PNOZmulti Controller – Base units Type PNOZ m0p PNOZ m0p PNOZ m1p/ PNOZ m1p (coated version) PNOZ m2p Modular safety system PNOZmulti I/O – Input modules Type PNOZ mi1p/ PNOZ mi1p (coated version) ...

Page 55

... Plug-in screw terminals 793 100 (1 set) 793 100 (1 set) 1) 793 100 (1 set) Plug-in screw terminals Technical documentation 793 400 on PNOZmulti (1 set) modular safety sys tems: Webcode 0685 793 400 (1 set) Online information at www.pilz.com 1) not for PNOZ mi2p 53 ...

Page 56

Technical details – PNOZmulti Modular safety system PNOZmulti I/O – Output modules Type PNOZ mo1p/ PNOZ mo1p (coated version) PNOZ mo1p PNOZ mo3p PNOZ mo2p/ PNOZ mo2p (coated version) PNOZ mc1p PNOZ mo4p/ PNOZ mo4p (coated version) PNOZ mc1p/ PNOZ ...

Page 57

... Plug-in screw terminals 793 400 (1 set) 793 400 (1 set) 793 520 (1 set) 793 536 (1 set) 793 700 (1 set) Technical documentation on PNOZmulti modular safety sys tems: Webcode 0685 Online information at www.pilz.com 55 ...

Page 58

Technical details – PNOZmulti Modular safety system PNOZmulti I/O – Monitoring module Type PNOZ ms1p/ PNOZ ms2p PNOZ ms1p Modular safety system PNOZmulti COM – Connection module Type PNOZ ml1p Modular safety system PNOZmulti PAA – Cable Type PNOZ msi1p ...

Page 59

... PNOZ msi5p 15/15 Bo/Rex, 2.5 m ...................773 857 • PNOZ msi15p 15/15 PMCtendo, 2.5 m ...........773 874 • Other versions available • ....................................................................773 890 • Other versions available Pending for PNOZ ml1p 2) Not for PNOZ ml1p Technical documentation on PNOZmulti modular safety sys tems: Webcode 0685 Online information at www.pilz.com 57 ...

Page 60

Technical details – PNOZmulti Modular safety system PNOZmulti COM – Fieldbus modules Type PNOZ mc3p PNOZ mc3p PNOZ mc4p/ PNOZ mc4p (coated version) PNOZ mc4p PNOZ mc5p PNOZ mc5p PNOZ mc5.1p PNOZ mc0p PNOZ mc5.1p PNOZ mc0p 58 Technical details ...

Page 61

... Plug-in terminals (either with cage clamp or screw connection) • Connected to base unit via a link on the back of the unit Order numbers 773 721 773 722 coated version ...... 773 729 773 723 773 728 Technical documentation on PNOZmulti modular safety sys tems: 773 720 Webcode 0685 Online information at www.pilz.com 59 ...

Page 62

Technical details – PNOZmulti Modular safety system PNOZmulti COM – Fieldbus modules Type PNOZ mc6p PNOZ mc6p PNOZ mc7p PNOZ mc7p PNOZ mc8p PNOZ mc8p PNOZ mc9p PNOZ mc9p 60 Technical details Application range Supply voltage (U Fieldbus module 24 ...

Page 63

... Max. 1 fi eldbus module can be connected to the base unit • Connected to base unit via a link on the back of the unit Order numbers 773 724 coated version ...... 773 727 773 726 coated version ...... 773 725 773 730 773 731 Technical documentation on PNOZmulti modular safety sys tems: Webcode 0685 Online information at www.pilz.com 61 ...

Page 64

Technical details – PNOZmulti Modular safety system PNOZmulti PASsystem – Software Type PNOZmulti Confi gurator PNOZmulti Service Tool Modular safety system PNOZmulti PAA – Accessories Type PNOZmulti Tool Kit 62 Technical details PNOZmulti Features • Runs under Windows ® 2000 ...

Page 65

... Time-restricted licences for PNOZmulti Confi gurator: …S (2 months), …R (3 months) or …Q (4 months Licence type 2) 773 010… 3) Technical documentation on PNOZmulti modular safety sys tems: Webcode 0685 Online information at www.pilz.com 63 ...

Page 66

Modular safety system PNOZpower Switching high loads safely The modular PNOZpower safety system is suitable for monitoring E-STOPs, safety gates and light beam devices. PNOZpower can switch currents AC/DC per contact. An overall breaking capacity ...

Page 67

... Complete solution com- prising evaluation devices, compatible sensor tech- nology and control and signal devices Connection to PNOZmulti PNOZpower modules can be connected to the modular PNOZmulti safety system via the coupling connector PNOZ pe2p. Keep up-to-date on PNOZpower modular safety systems: Webcode 0245 Online information at www.pilz.com 65 ...

Page 68

Selection guide – PNOZpower Modular safety system – PNOZpower Type Application area PNOZ p1p Base unit PNOZ p1vp Base unit, delayed PNOZ pe1p Control module PNOZ pe2p Bus interface PNOZ pps1p Power supply Modular safety system – PNOZpower Type PNOZ ...

Page 69

... VAC AC3 DC1 - 24 V/4 A/ V/8 A/200 V/16 A/400 W 240 V/3 V/16 A/400 W 400 V/5.5 kW 500 V/4 V/4 A/96 W Housing width 22.5 23.5 45 Housing width in mm Technical documentation 22.5 on PNOZpower modular safety 45 sys tems: 90 Webcode 0685 90 Online information at www.pilz.com 22.5 67 ...

Page 70

Technical details – PNOZpower Modular safety system – PNOZpower Type PNOZ p1p PNOZ p1vp PNOZ p1p PNOZ pe1p PNOZ pe1p PNOZ pe2p PNOZ pe2p 68 Application area Supply voltage Base unit 24 VDC Base unit, 24 VDC delayed Control module ...

Page 71

... Output connected to PNOZpower bus • Connection between PNOZ pe2p and expansion modules via PNOZpower bus Order numbers Plug-in screw terminals 773 300 30 s .....................................773 950 300 s .....................................773 951 773 900 779 125 Technical documentation on PNOZpower modular safety sys tems: Online information at www.pilz.com 69 Webcode 0685 ...

Page 72

Technical details – PNOZpower Modular safety system – PNOZpower Type PNOZ po3p/ PNOZ po4p PNOZ po3.1p PNOZ po3p PNOZ po3.2p PNOZ po3.2p PNOZ po3.3p PNOZ pps1p PNOZ pps1p 70 Application Inputs/outputs area Expansion • PNOZ po3p: modules - 3 safety ...

Page 73

... VDC at the plug-in connector on the back of the unit for the PNOZpower bus and at the terminals • LEDs for supply voltage, output voltage and fault PNOZ po3p.........773 634 PNOZ po4p.........773 635 Technical documentation on PNOZpower modular safety systems: Webcode 0685 Online information at www.pilz.com 71 ...

Page 74

... Republic of Korea pilz.fi @pilz.dk Telephone: +82 2 2263 9541 Telefax: +82 2 2263 9542 E-Mail: info@pilzkorea.co.kr MX Pilz de Mexico R.L. de C.V. Automatización Segura Circuito Pintores # 170 Cd. Satelite +33 3 88108000 C.P. 53100 siege@pilz-france.fr Naucalpan de Juarez, Edo. de Mexico Mexico Telephone: +52 55 5572 1300 ...

Related keywords