SMU315LP BANNER ENGINEERING, SMU315LP Datasheet

Photoelectric Sensor

SMU315LP

Manufacturer Part Number
SMU315LP
Description
Photoelectric Sensor
Manufacturer
BANNER ENGINEERING
Type
Retroreflectiver
Datasheets

Specifications of SMU315LP

Output Current
3A
Sensor Output
Relay
Supply Voltage Range Dc
24V To 240V
Contact Current Max
3A
Switch Terminals
Cable
Sensing Range Min
10mm
Sensor Input
Optical
Output Type
Relay
Sensing Range Max
3m
Brand/series
Mini-Beam®
Current, Switching
3 A
Function
Proximity
Indicator
LED
Ip Rating
IP67
Light Source
Visible Red LED
Material, Body
ABS
Material, Cover
Clear Acrylic
Material, Lens
Acrylic
Mounting Type
Panel
Output
Relay
Primary Type
Photoelectric
Range, Measurement
3 m
Response Time
20 ms (Max.)
Sensing Mode
Polarized Retro-Reflective
Standards
UL Listed
Technology
Photoelectric
Temperature, Operating
-20 to +55 °C
Termination
Cable
Voltage, Supply
240 VAC/VDC
Voltage, Switching
250/30 VAC/VDC
Lead Free Status / Rohs Status
RoHS Exempt Product
*U.S. Patent no. 4356393
Printed in USA
*9 m (30') cables are available by adding the suffix “W/30” to the model number of any cabled sensor (e.g., SMU31E W/30).
SMU31E
SMU31R
SMU31EL
SMU31RL
Models
MINI-BEAM Universal Voltage Series Opposed-Mode Emitters (E) and Receivers (R)
Range
(100')
30 m
(10')
3 m
Their small effective beam size is ideal for accuracy-dependent applications, particularly
when used with an aperture (see page 10). They have the power to burn through dust
and dirt, and may even sense opaque materials through a thin-walled container.
E: 2-wire
R: 5-wire
E: 2-wire
R: 5-wire
Cable*
2 m (6.5')
2 m (6.5')
2 m (6.5')
2 m (6.5')
IMPORTANT: SEE SAFETY WARNING ON BACK PAGE
Universal voltage photoelectric sensors with electromechanical relay output
MINI-BEAM Universal Voltage Series
24 to 240V dc
24 to 240V dc
24 to 240V ac
24 to 240V ac
• Popular, compact MINI-BEAM package
• Universal supply voltage: 24 to 240V ac, 50/60 Hz; 24 to 240V dc (1.5 watts or
• Easy-to-operate sensors with few necessary adjustments
• Light/Dark Operate select switch and 15-turn Gain potentiometer are protected
• Multiple sensing modes include: Opposed, Retroreflective, Diffuse, Divergent
• 3-amp SPDT (Single-Pole-Double-Throw) electromechanical relay output
• Exclusive, patented Alignment Indicating Device system (AID™*) lights a rear-
• Wide array of mounting options, including 18 mm in-line thread
• Integral, unterminated cables 2 m (6.5') or 9 m (30') long available
Voltage
Universal
Universal
Supply
2.5VA maximum)
by a gasketed clear acrylic cover
and Convergent, plus Glass and Plastic Fiber Optic models
panel-mounted LED indicator whenever the sensor sees a light condition;
superimposed pulse rate indicates received light signal strength
or
or
mechanical
mechanical
Electro-
Electro-
Output
MINI-BEAM Universal Voltage Series Features
SPDT
SPDT
Type
Relay
Relay
E
X
C
E
S
S
G
A
N
I
G
N
E
X
C
E
S
S
A
I
1000
1000
100
100
10
10
1
.033 ft
.01 m
1
.33 ft
.1 m
Excess Gain
.10 m
.33 ft
1.0 m
3.3 ft
DISTANCE
DISTANCE
SMU31EL & SMU31RL
SMU31E & SMU31R
Opposed Mode
Opposed Mode
1.0 m
3.3 ft
10 m
33 ft
10 m
100 m
33 ft
330 ft
750 mm
500 mm
250 mm
250 mm
500 mm
750 mm
300 mm
200 mm
100 mm
100 mm
200 mm
300 mm
0
0
0
0
Opposed Mode
SMU31E & SMU31R
Opposed Mode
SMU31EL & SMU31RL
20 ft
.6 m
6 m
Beam Pattern
2 ft
1.2 m
12 m
40 ft
4 ft
DISTANCE
DISTANCE
Infrared, 880 nm
P/N 55230L9B
1.8 m
18 m
60 ft
6 ft
2.4 m
24 m
80 ft
8 ft
3.0 m
30 m
100ft
10 ft
30.0 in
20.0 in
10.0 in
0
10.0 in
20.0 in
30.0 in
12.0 in
8.0 in
4.0 in
0
4.0 in
8.0 in
12.0 in

Related parts for SMU315LP

SMU315LP Summary of contents

Page 1

Patent no. 4356393 Their small effective beam size is ideal for accuracy-dependent applications, particularly when used with an aperture (see page 10). They have the power to burn through dust and dirt, and may even sense opaque materials through ...

Page 2

... Website: http://www.baneng.com • Tel: 888.373.6767 Non-polarized Polarized P Visible red, 650 nm Beam Pattern SMU315LV SMU315LV Retroreflective Mode Retroreflective Mode With BRT-3 Reflector 1 DISTANCE 3 DISTANCE SMU315LP SMU315LP 60 mm Retroreflective Mode Retroreflective Mode With BRT-3 Reflector 1.2 m 1 DISTANCE DISTANCE 3.0 in 2 1.0 in 2 ...

Page 3

... Focus: 3.0 mm (0.12" (30') cables are available by adding suffix “W/30” to the model number of any cabled sensor (e.g., SMU315CV W/30) Banner Engineering Corp. • Minneapolis, U.S.A. Website: http://www.baneng.com • Tel: 888.373.6767 MINI-BEAM Universal Voltage Series Supply Output Excess Gain ...

Page 4

... Diffuse Mode 1. BT13S BT23S Fiber 0.65 mm 1.30mm 1. 100 mm 0.2 in 0.4 in 0 DISTANCE DISTANCE Banner Engineering Corp. • Minneapolis, U.S.A. Website: http://www.baneng.com • Tel: 888.373.6767 IT23S 500 0.075 in 0.050 in 0.025 in 0 BT23S 0.025 in 0.050 in 0.075 in 37.5 mm 1.2 in 1.5 in ...

Page 5

... SMU315FP W/30) Banner Engineering Corp. • Minneapolis, U.S.A. Website: http://www.baneng.com • Tel: 888.373.6767 MINI-BEAM Universal Voltage Series Supply Output Excess Gain ...

Page 6

... Temperature: -20° to +55°C (-4° to +131°F) Maximum relative humidity: 90% at 50°C (non-condensing) Application Notes Install transient suppressor (MOV) across contacts switching inductive loads. 6 page 24 to 240V dc (1.5 watts or 2.5 VA maximum) Banner Engineering Corp. • Minneapolis, U.S.A. Website: http://www.baneng.com • Tel: 888.373.6767 ...

Page 7

... NO *Connection of dc power is without regard to polarity NOTE: Install transient suppressor (MOV) across contacts switching inductive loads. Banner Engineering Corp. • Minneapolis, U.S.A. Website: http://www.baneng.com • Tel: 888.373.6767 MINI-BEAM Universal Voltage Series ø (ø0.11") Clearance (2) M18 Thread 2 m (6.5') Cable (Mounting Nut Supplied) 27.4 mm (1.08" ...

Page 8

... Troubleshooting MINI-BEAM Universal Voltage Series sensors have no field-serviceable parts, other than replaceable lenses (see page 9). 8 page Figure 1. MINI-BEAM Universal Voltage Series indicators Banner Engineering Corp. • Minneapolis, U.S.A. Website: http://www.baneng.com • Tel: 888.373.6767 ...

Page 9

... Replacement lens for FP (old style) UC-300FP2 Replacement lens for FP (current style) UC-300L Replacement lens for LV and D UC-300LP Replacement lens for LP Banner Engineering Corp. • Minneapolis, U.S.A. Website: http://www.baneng.com • Tel: 888.373.6767 MINI-BEAM Universal Voltage Series Accessories Retroreflective Targets Replacement Lens Assemblies Possible Sensing Mode or Range Changes — ...

Page 10

... Banner Engineering Corp. • Minneapolis, U.S.A. Website: http://www.baneng.com • Tel: 888.373.6767 (36") 2.0 m (80") 5.8 m (19') 3.4 m (11') 5.2 m (17') 8.5 m (28') (36') 3.4 m (11') 5.5 m (18') 8 ...

Page 11

... Banner Engineering Corp. • Minneapolis, U.S.A. Website: http://www.baneng.com • Tel: 888.373.6767 MINI-BEAM Universal Voltage Series MINI-BEAM Mounting Brackets SMB312PD R 5.1 mm (0.20") 4.32 mm (0.170") Slot (2) 10 (TYP) 2.5 mm (0.10") 20.3 mm (0.80") ...

Page 12

... A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection. Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN 55441 • Phone: 888.373.6767 • http:\\www.baneng.com • Email: sensors@baneng.com MINI-BEAM Mounting Brackets SMB18SF 42 ...