Photoelectric Sensor

S51-PA-5-C10-PK

Manufacturer Part NumberS51-PA-5-C10-PK
DescriptionPhotoelectric Sensor
ManufacturerIDEC
S51-PA-5-C10-PK datasheet
 


Specifications of S51-PA-5-C10-PK

Sensing Range0cm To 10cmOutput Current100mA
Sensor OutputPNPSupply Voltage Range Dc10V To 30V
Sensor HousingCylinder RotatableSensing Range Min0cm
Sensor InputOpticalSensing Range Max10cm
Lead Free Status / RoHS StatusLead free / RoHS Compliant  
1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
6
Page 6
7
Page 7
8
Page 8
9
Page 9
10
Page 10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
Page 3/26

Download datasheet (4Mb)Embed
PrevNext
Sensors
Specifi cations
Long Diffuse Proximity Operating Distance
1 - 40cm
Short Diffuse Proximity Operating Distance
0 - 10cm
Retro-refl ective Operating Distance
0.1 - 4m on R2
Polarized Retro-refl ective Operating
0.1 - 3m on R2
Distance
Through-beam Operating Distance
0 - 18m
Power Supply
10 - 30V DC
Ripple
≤ 2 Vpp
Current Draw
≤ 35 mA
Infrared LED 880 nm
Light Emission
2
Red LED 650 nm (B01 models)
Setting
Sensitivity adjustment (B01, C01 models)
Yellow OUTPUT LED (excl. G00 models)
Indicators
Green POWER LED (G00 models)
Output Type
NPN or PNP versions
Output Current
≤ 100mA
Saturation Voltage
≤ 2V
1ms
Response Time
4ms (F00 mod.)
≤ 500Hz
Switching Frequency
≤ 120Hz (F00 mod.)
Operating Mode
dark/light selectable
Auxiliary Functions
Test + and Test - (G00 mod.)
2m ø4 mm cable
Connection
M12 4-pole connector
Electrical Protection
Class 2
Mechanical Protection
IP67
Protection Devices
A, B
Housing Material
PBT
Lens Material
PMMA
Weight
25g max.
Operating Temperature
-25 to +55ºC
Storage Temperature
-25 to +70ºC
Reference Standard
EN60947-5-2, UL 508
1. Limit values.
2. Average life of 100,000 hrs with T
= +25ºC.
A
3. 270º single-turn sensitivity adjustment.
4. With L/D input not connected the proximity models function in the light mode and the
retro-refl ective and through-beam models in the dark mode; the light mode can be selected
by connecting the L/D input to +V DC, the dark mode connecting it to 0V DC.
5. Emitter off with Test+ connected to +V DC and Test- to 0V DC.
6. PVC, 4 x 0.14mm
2
7. M12 connector compatible with quick connection systems.
8. A - reverse polarity protection
B - overload and short-circuit protection
Detection Diagrams
Long Diffused C01
1
Short Diffused C10
3
Retro-refl ective A00
Polarized Retro-refl ective B01
4
5
6
7
Through-beam F00/G00
8
USA: 800-262-IDEC
Canada: 888-317-IDEC
Tubular: S51 Series
Gray 18%
White 90%
Gray 18%
White 90%
R2
R5
R2
R5
II3D
135