HSCMRNN015PAAA5 Honeywell Sensing and Control, HSCMRNN015PAAA5 Datasheet

no-image

HSCMRNN015PAAA5

Manufacturer Part Number
HSCMRNN015PAAA5
Description
Pressure Sensor
Manufacturer
Honeywell Sensing and Control
Series
TruStability™r
Datasheet

Specifications of HSCMRNN015PAAA5

Interface Type
PCB Mount
Operating Pressure Range
0 To 15psi
Sensor Output
Analog
Supply Current
2mA
External Depth
10mm
Voltage Rating
5V
Port Style
Radial
Pressure Measurement Type
Absolute
Pressure Type
Absolute
Operating Pressure
0 ~ 15 PSI
Port Size
*
Output
ANALOG
Accuracy
±0.25%
Voltage - Supply
4.75 V ~ 5.25 V
Termination Style
PCB
Operating Temperature
-20°C ~ 85°C
Package / Case
8-SMD, Side Port
Factory Setting
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
DESCRIPTION
The TruStability High Accuracy Silicon Ceramic (HSC) Series
is a piezoresistive silicon pressure sensor offering a ratiometric
analog output for reading pressure over the specified full scale
pressure span and temperature range.
The HSC Series is fully calibrated and temperature
compensated for sensor offset, sensitivity, temperature effects,
and non-linearity using an on-board Application Specific
Integrated Circuit (ASIC). Calibrated output values for pressure
are updated at approximately 1 kHz.
The HSC Series is calibrated over the temperature range of
0 C to 50 C [32 F to 122 F]. The sensor is characterized for
operation from a single power supply of either 3.3 Vdc or
5.0 Vdc.
FEATURES
Industry-leading long-term stability
Extremely tight accuracy of 0.25% FSS BFSL (Full Scale
Span Best Fit Straight Line)
Total error band of 1% full scale span maximum
Modular and flexible design offers customers a variety of
package styles and options, all with the same industry-
leading performance specifications
Miniature 10 mm x 10 mm [0.39 in x 0.39 in] package
Low operating voltage
Extremely low power consumption
Ratiometric analog output
High resolution (min 0.03 %FSS)
These sensors measure absolute, differential, and gage
pressures. The absolute versions have an internal vacuum
reference and an output value proportional to absolute
pressure. Differential versions allow application of pressure to
either side of the sensing diaphragm. Gage versions are
referenced to atmospheric pressure and provide an output
proportional to pressure variations from atmosphere.
The TruStability
non-corrosive, non-ionic gases, such as air and other dry
gases. An available option extends the performance of these
sensors to non-corrosive, non-ionic liquids.
All products are designed and manufactured according to ISO
9001 standards.
Precision ASIC conditioning and temperature compensated
over 0 C to 50 C [32 F to 122 F] temperature range
RoHS compliant
Virtually insensitive to mounting orientation
Internal diagnostic functions increase system reliability
Also available with I
Absolute, differential and gage types
Pressure ranges from 1 psi to 150 psi (60 mbar to 10 bar)
Custom calibration available
Various pressure port options
Liquid media option
®
pressure sensors are intended for use with
2
C or SPI digital output

Related parts for HSCMRNN015PAAA5

HSCMRNN015PAAA5 Summary of contents

Page 1

... RoHS compliant Virtually insensitive to mounting orientation Internal diagnostic functions increase system reliability 2 Also available with SPI digital output Absolute, differential and gage types Pressure ranges from 1 psi to 150 psi (60 mbar to 10 bar) Custom calibration available Various pressure port options Liquid media option ...

Page 2

POTENTIAL APPLICATIONS Medical: - Airflow monitors - Anesthesia machines Blood analysis machines - Gas chromatography - - Gas flow instrumentation Kidney dialysis machines - Oxygen concentrators - - Pneumatic controls - Respiratory machines Sleep apnea equipment - - Ventilators Table ...

Page 3

... J-STD-020-C Port 1 (Pressure Port) high temperature polyamide alumina ceramic epoxy, silicone ceramic, glass, solder, silicon ® sensors are dead-ended devices. Particulates can accumulate Port 2 (Reference Port) high temperature polyamide alumina ceramic epoxy, silicone silicon, glass, gold, solder Honeywell Sensing and Control 3 ...

Page 4

... Notes: 11. The transfer function limits define the output of the sensor at a given pressure input. By specifying Pmin. and Pmax., the output at Pmin. and Pmax., the complete transfer function of the sensor is defined. See Figure 2 for a graphical representation of the transfer function. Other transfer functions are available. Contact Honeywell Customer Service for more information. ...

Page 5

... Honeywell Sensing and Control Port 2) Long-term Stability (1000 hr, 0.25% FSS 0.25% FSS 0.25% FSS 0.25% FSS 0.25% FSS 0.35% FSS ...

Page 6

... Notes: 16. Overpressure: The maximum pressure which may safely be applied to the product for it to remain in specification once pressure is returned to the operating pressure range. Exposure to higher pressures may cause permanent damage to the product. Unless otherwise specified this applies to all available pressure ports at any temperature with the operating temperature range. ...

Page 7

... DIA [0.076] 6,99 PORT 1 PORT 2 [0.275] PORT 1 9, [0.364] 2,54 TYP. 11,21 [0.100] [0.441] 3,78 [0.149] 8X 0,46 [0.018] Honeywell Sensing and Control 10,0 [0.39] 13,35 [0.525] 4,2 [0.17] 1,93 DIA. [0.076] 10,0 [0.39] 13,35 [0.525] 7 ...

Page 8

... Figure 5. SMT Pressure Port Dimensional Drawings (For reference only: mm [in]) SMT NN: No ports 5,44 [0.214 PORT 1 PORT 4,80 2,54 TYP. [0.189] [0.100] 6,41 [0.252] SMT LN: Single axial barbless port 5,80 [0.228 2,47 DIA. [0.097] PORT 2 PORT 4,80 2,54 TYP. [0.189] [0.100] 6,77 [0 ...

Page 9

... DIA. [0.097] 15,2 [0.60 0,25 4X 0,51 [0.010] [0.020] 17,78 [0.700] PORT 1 2X 4,78 DIA. [0.188] 20,16 [0.794 2,54 TYP. [0.100] 17,78 [0.700] PORT 1 4.78 DIA. [0.188] 20,16 [0.794 2,54 TYP. [0.100] Honeywell Sensing and Control 2,54 TYP. [0.100] 2,54 TYP. [0.100] 9 ...

Page 10

Figure 6. SIP Package Dimensional Drawings (continued) SIP GN: Ribbed fastener mount, single axial barbed port 27,96 [1.101] 21,60 [0.850] SIP NB: Fastener mount, dual axial ports, same side 27,31 [1.075] 21,60 [0.850 SIP RN: Single radial barbed ...

Page 11

... PORT 2 PORT 1 PORT 0,25 2,54 TYP. 4X 0,51 [0.010] [0.100] [0.020] 5,36 [0.211] PORT 1 15,24 DIA. [0.600] 12,5 [0.49 0,25 [0.010] 4X 0,51 [0.100] [0.020] PORT 2,54 TYP. [0.100] Honeywell Sensing and Control PORT 1 28,96 [1.140] 11,27 [0.444 2,54 TYP. 11 ...

Page 12

WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or ...