HSCMRNN015PAAA5 Honeywell Sensing and Control, HSCMRNN015PAAA5 Datasheet - Page 3

no-image

HSCMRNN015PAAA5

Manufacturer Part Number
HSCMRNN015PAAA5
Description
Pressure Sensor
Manufacturer
Honeywell Sensing and Control
Series
TruStability™r
Datasheet

Specifications of HSCMRNN015PAAA5

Interface Type
PCB Mount
Operating Pressure Range
0 To 15psi
Sensor Output
Analog
Supply Current
2mA
External Depth
10mm
Voltage Rating
5V
Port Style
Radial
Pressure Measurement Type
Absolute
Pressure Type
Absolute
Operating Pressure
0 ~ 15 PSI
Port Size
*
Output
ANALOG
Accuracy
±0.25%
Voltage - Supply
4.75 V ~ 5.25 V
Termination Style
PCB
Operating Temperature
-20°C ~ 85°C
Package / Case
8-SMD, Side Port
Factory Setting
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 3. Environmental Specifications
Table 4. Wetted Materials
Notes:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. Contact Honeywell Customer Service for detailed material information.
Parameter
Humidity:
Vibration
Shock
Life
Solder reflow
Parameter
Covers
Substrate
Adhesives
Electronic components
CAUTION
PRODUCT DAMAGE
Failure to comply with these instructions may result in product damage.
Dry gases only (See “Options N and D” in Figure 1.)
Liquid media (See “Options T and V” in Figure 1.)
Absolute maximum ratings are the extreme limits the device will withstand without damage.
Ratiometricity of the sensor (the ability of the device to scale to the supply voltage) is achieved within the specified operating voltage for each
option.
The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.
The compensated temperature range is the temperature range over which the sensor will produce an output proportional to pressure within
the specified performance limits.
The operating temperature range is the temperature range over which the sensor will produce an output proportional to pressure but may not
remain within the specified performance limits.
Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at
Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range.
Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal
effect on span, and thermal hysteresis.
Full Scale Span (FSS) is the algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of
the pressure range. (See Figure 1 for ranges.)
Life may vary depending on specific application in which sensor is utilized.
Ensure liquid media is applied to Port 1 only; Port 2 is not compatible with liquids.
Ensure liquid media contains no particulates. All TruStability
inside the sensor, causing damage or affecting sensor output.
Recommend that the sensor be positioned with Port 1 facing downwards; any particulates in the system are less likely to
enter and settle within the pressure sensor if it is in this position.
Ensure liquid media does not create a residue when dried; build-up inside the sensor may affect sensor output. Rinsing of a
dead-ended sensor is difficult and has limited effectiveness for removing residue.
Ensure liquid media are compatible with wetted materials. Non-compatible liquid media will degrade sensor performance and
may lead to sensor failure.
9
25 °C [77 °F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.
10
Port 1 (Pressure Port)
high temperature polyamide
alumina ceramic
epoxy, silicone
ceramic, glass, solder, silicon
®
sensors are dead-ended devices. Particulates can accumulate
Characteristic
0% to 95% RH, non-condensing
100% condensing or direct liquid media on Port 1
MIL-STD-202F, Curve AK (20.7 g random)
MIL-STD-202F, Method 213B, Condition F
1 million cycles minimum
J-STD-020-C
Port 2 (Reference Port)
high temperature polyamide
alumina ceramic
epoxy, silicone
silicon, glass, gold, solder
Honeywell Sensing and Control
3

Related parts for HSCMRNN015PAAA5