83699 SENSONOR TECHNOLOGIES AS, 83699 Datasheet

no-image

83699

Manufacturer Part Number
83699
Description
SENSOR, PRESSURE, COMP, SP100-1T
Manufacturer
SENSONOR TECHNOLOGIES AS
Datasheet

Specifications of 83699

Operating Temperature Range
-40°C To +125°C
Pressure Type
Absolute
Ic Generic Number
SP100-1T
No. Of Pins
14
Operating Pressure Range
0 To 100kPa
Sensor Case Style
SOIC
Supply Voltage
RoHS Compliant
Rohs Compliant
Yes
DATASHEET
SP100 PRESSURE SENSOR SERIES
SP100-1(T), SP100-2(T)
SP100 Series
Compensated Pressure Sensors
The SP100 pressure sensors are calibrated and digitally compensated silicon piezoresistive sensors with SPI
interface. In addition to pressure these sensors provides temperature and supply voltage measurements. Each
sensor has a unique electronic sensor ID, and has a built in self diagnosis system. SP100 sensors can easily be
used in a broad range of applications and interfaces directly to a micro controller without the need of any additional
components.
SP100 series of sensors has excellent media compatibility due to a patented bulk micromachined triple stack sensor
die design, utilizing buried piezoresistive elements and backside media access to pressure diaphragm. With this
design the internal connectors and piezoresistive elements of the pressure bridge are isolated from the
measurement media. This isolation is of great importance in terms of stability and reliability of the sensor over a very
long lifetime.
The SP100 pressure sensor design has been proven in harsh environment applications during a period of more than
10 years, making these sensors ideal choices for demanding applications where simple solutions are needed to
quickly implement reliable and accurate pressure measurements.
SP100-1 and SP100-2 belongs to the lower pressure range of SP100 sensors.
SP100-1
SP100-1T
SP100-2
SP100-2T
TS1483 rev. 1
- 1 -

Related parts for 83699

83699 Summary of contents

Page 1

... This isolation is of great importance in terms of stability and reliability of the sensor over a very long lifetime. The SP100 pressure sensor design has been proven in harsh environment applications during a period of more than 10 years, making these sensors ideal choices for demanding applications where simple solutions are needed to quickly implement reliable and accurate pressure measurements ...

Page 2

... Sensonor Technologies makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does Sensonor Technologies assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation consequential or incidental damages ...

Page 3

... DATASHEET Table of Contents 1 Product Description ............................................................................................................................................... - 4 - 1.1 Features ....................................................................................................................................................- 4 - 1.2 Overview....................................................................................................................................................- Measurement Performance ................................................................................................................................... - 5 - 2.1 Pressure Measurement Performance .......................................................................................................- 5 - 2.2 Temperature Measurement Performance .................................................................................................- 5 - 2.3 Supply Voltage Measurement Performance .............................................................................................- Recommended Operating Conditions ................................................................................................................... - Absolute Maximum Ratings................................................................................................................................... - Wake-Up and Reset Outputs................................................................................................................................. - Serial Interface....................................................................................................................................................... - 7 - 6.1 SPI Protocol...............................................................................................................................................- 8 - 6.2 SPI Commands .........................................................................................................................................- ...

Page 4

... Overview SP100 is an integrated MEMS pressure sensor designed for air pressure measurements. The sensor has a digital interface designed for use in microcontroller applications. SP100 is housed pin small outline package, and requires no external components. SP100-1T and SP100-2T have a tube connection option (for ‘T’ version sensors) ...

Page 5

... T corr PRODUCT Where the temperature reported by the product, and PRODUCT Δ T should be subtracted from the reported temperature to achieve specified accuracy. corr TS1483 rev. 1 SP100 PRESSURE SENSOR SERIES Specification Unit Typ Temperature [°C] kPa/lsb 0.36 -40 to 125 kPa/lsb 0.36 -40 to 125 kPa ± ...

Page 6

... Supply voltage between measurements Input pressure SP100-1 2) SP100-1T SP100-2 SP100-2T Notes: 1) This is the voltage range where measurement accuracy is specified. 2) All pressure values given in this specification are absolute values. TS1483 rev. 1 SP100 PRESSURE SENSOR SERIES 50 Ambient conditions Specification Supply voltage [V] Unit Typ V 1.8 – 3.6 2 ...

Page 7

... Serial Interface The SPI interface is the communication protocol to the external microcontroller. This maximum serial clock frequency is 500 kHz. The SPI consists of a shift register, a command latch and failure latches, and encoder/decoder logic. TS1483 rev. 1 SP100 PRESSURE SENSOR SERIES Min -40 -40 -40 -0.3 -0 ...

Page 8

... The control bytes are described in chapter 6.2. Some control bytes require an additional data byte. For such command, the data byte must be transmitted first, before the command byte. TS1483 rev. 1 SP100 PRESSURE SENSOR SERIES SP100-1(T), SP100-2( ...

Page 9

... SP100-1(T), SP100-2(T) Description Measure pressure Read compensated pressure data, high byte Read compensated pressure data, low byte Read raw pressure data, high byte Read raw pressure data, low byte Read ID, high byte Read ID, mid byte Read ID, low byte Measure battery voltage ...

Page 10

... Remark: the temperature byte may show values outside this range, which have an undefined accuracy. 6.6 Pressure Byte The pressure (in kPa) is obtained by multiplying the value in the pressure byte by the given resolution in kPa/lsb (see section 0). 6.7 Supply Voltage Byte The supply voltage ( obtained by multiplying the value in the supply byte by 0 ...

Page 11

... After copying the PROM contents to the shadow register bit CRC is calculated using the CCITT polynomial. This checksum is stored with the data, and is verified for each measurement cycle error is detected, the product will return a single byte with an error code, and then enter PROM Reload / Reset state. TS1483 rev. 1 SP100 PRESSURE SENSOR SERIES SP100-1(T), SP100-2(T) Comment Typ ...

Page 12

... Overflow/Underflow The overflow bit will be set by an over- or underflow in the ADC or compensation module. For temperature and supply measurements, ADC overflow will not saturate the compensated output value. TS1483 rev. 1 SP100 PRESSURE SENSOR SERIES SP100-1(T), SP100-2( ...

Page 13

... Dimension does not include mold flash, protrusions or gate burrs. Mold flash, protrusions and gate burrs do not exceed 0.15mm (0.006 inch) per side. 2) Dimension does not include inter-lead flash or protrusions. Inter-lead flash and protrusions do not exceed 0.25mm (0.010 inch) per side. TS1483 rev. 1 SP100 PRESSURE SENSOR SERIES SP100-1(T), SP100-2( ...

Page 14

... DATASHEET 11.2 Tube Connection (option) The SP100 models with ‘T’ in the model name features two different tube connection options to ease pressure connection. Figure 11.3 Illustration of the SP100 series with tube connection (type A) Figure 11.5 Mechanical drawing: Section A in Figure 11.4 of tube connection (type A) TS1483 rev ...

Page 15

... Figure 11.8 Marking of the SP100 series The variables in Figure 11.8 have the following meaning: YYWWXXX : Lot number NNNNNNNNNN: Product name O: Pin 1 marking TS1483 rev. 1 SP100 PRESSURE SENSOR SERIES Table 11.1 Pin configuration description PIN NAME FUNCTION 1 WAKE UP Wake up output signal 2 RESET ...