SCX15DN SENSYM, SCX15DN Datasheet - Page 3

PRESSURE SENSOR, 0-15PSID

SCX15DN

Manufacturer Part Number
SCX15DN
Description
PRESSURE SENSOR, 0-15PSID
Manufacturer
SENSYM
Datasheet

Specifications of SCX15DN

External Depth
26.2mm
External Length / Height
25.4mm
External Width
27.9mm
Fixing Centres
21.6mm
Hysteresis
1%
Lead Spacing
2.54mm
Linearity
1%
Operating Pressure Range
0 To 15psid

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SCX15DN
Manufacturer:
MICROCHIP
Quantity:
1 000
TYPICAL PERFORMANCE CHARACTERISTICS
GENERAL DISCUSSION
The SCX series devices give a voltage output which is directly pro-
portional to applied pressure. The devices will give an increasing
positiv going output when increasing pressure is applied to pressure
port P
the output will increase with decreases in pressure. The devices
are ratiometric to the supply voltage and changes in the supply
voltage will cause proportional changes in the offset voltage and
full-scale span. Since for absolute devices pressure is applied to
port P
User calibration
The SCX devices are fully calibrated for offset and span and should
therefore require little if any user adjustment in most applications.
For precise span and offset adjustments, refer to the applications
section herein.
Vacuum reference (absolute device)
Absolute sensors have a hermetically sealed vacuum reference
chamber. The offset voltage on these units is therefore measured
at vacuum, 0 psia. Since all pressure is measured relative to a
vacuum reference,all changes in barometric pressure or changes
in altitude will cause changes in the device output.
August 2005 / 053
B
A
, output polarity will be reversed.
of the device. If the input pressure connections are reversed,
Precision compensated pressure sensors
Media compatibility
SCX devices are compatible with most non-corrosive gases.
Because the circuit is coated with a protective silicon gel, many
otherwise corrosive environments can be compatible with the
sensors. As shown in the physical construction diagram below, fluids
must generally be compatible with silicon gel, plastic, aluminium,
RTV, silicon, and glass for use with Port B. For questions concerning
media compatibility, contact the factory.
MECHANICAL AND MOUNTING
CONSIDERATIONS
The SCX nylon housing is designed for convenient pressure con-
nection and easy PC board mounting. To mount the device horizon-
tally to a PC board, the leads can be bent downward and the package
attached to the board using either tie wraps or mounting screws.
For pressure attachment, tygon or silicon tubing is recommended.
All versions of the SCX sensors have two (2) tubes available for
pressure connection. For absolute devices, only port P
Applying pressure through the other port will result in pressure dead
ending into the backside of the silicon sensor and the device will
not give an output signal with pressure.
For gage applications, pressure should be applied the port P
P
differential pressure applications, to get proper output signal polarity,
port P
used as the low pressure port.
A
is then the vent port which is left open to the atmosphere. For
B
should be used as the high pressure port and P
www.sensortechnics.com
SCX Series
A
A
should be
is active.
B
. Port
3/10