H3BA-N 110 VAC Omron, H3BA-N 110 VAC Datasheet - Page 3

Multi Timer 11 Pin

H3BA-N 110 VAC

Manufacturer Part Number
H3BA-N 110 VAC
Description
Multi Timer 11 Pin
Manufacturer
Omron
Datasheet

Specifications of H3BA-N 110 VAC

Time Range
0.05s To 300hr
Power Consumption
1.6W
Reset Time
0.1s
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
H3BF-N8
Specifications
Note: Instantaneous output is available at any time range. To obtain instantaneous output, set to below 0.
Operating mode
Pin type
Operating/Reset method
Output type
Mounting method
Approved standards
Time unit
Setting
Rated supply voltage
Operating voltage range
Power reset
Power consumption
Control outputs
Accuracy of operating time
Setting error
Reset time
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Case color
Enclosure ratings
Weight
General
Time Ranges
Ratings
Characteristics
Item
1.2
3
12
30
0.05 to 1.2
0.3 to 3
1.2 to 12
3 to 30
Flicker OFF start
8-pin
Time-limit operation/Time-limit reset or self-reset
Relay output (DPDT)
DIN track mounting, surface mounting, and flush mounting
UL508, CSA C22.2 No.14
s (sec)
110 VAC (50/60 Hz), 220 VAC (50/60 Hz)
85% to 110% of rated supply voltage
Minimum power-opening time: 0.1 s
110 VAC: Approx. 2.9 VA (1.6 W)
220 VAC: Approx. 7.0 VA (1.6 W)
Contact output: 5 A at 250 VAC, resistive load (cosφ = 1)
±0.3% FS max. (±0.3% FS ±10 ms in ranges of 1.2 and 3 s)
±5% FS ±0.05 s max.
0.1 s max.
±0.5% FS max. (±0.5% FS ±10 ms in ranges of 1.2 and 3 s)
±2% FS max. (±2% FS ±10 ms in ranges of 1.2 and 3s)
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed
non-current-carrying metal parts)
2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
3 kV (between power terminals)
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts)
±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width:
100 ns/1 µs, 1-ns rise)
Malfunction: 8 kV
Destruction: 15 kV
Destruction:10 to 55 Hz with 0.75-mm single amplitude each in three directions
Malfunction:10 to 55 Hz with 0.5-mm single amplitude each in three directions
Destruction: 1,000 m/s
Malfunction: 100 m/s
Operating:–10°C to 55°C (with no icing)
Storage: –25°C to 65°C (with no icing)
Operating: 35% to 85%
Mechanical:20 million operations min. (under no load at 1,800 operations/h)
Electrical:
Light Gray (Munsell 5Y7/1)
IEC: IP40 (panel surface)
Approx. 100 g
100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)
1.2 to 12
3 to 30
12 to 120
30 to 300
x10 s (10 s)
2
(approx. 10G) each in three directions
2
(approx. 100G) each in three directions
H3BF-N8
0.12 to 1.2
0.3 to 3
1.2 to 12
3 to 30
min
h (hrs)
H3BF-N8
3

Related parts for H3BA-N 110 VAC