HUL175 LOOM KIT XP POWER, HUL175 LOOM KIT Datasheet

LOOM, PSU

HUL175 LOOM KIT

Manufacturer Part Number
HUL175 LOOM KIT
Description
LOOM, PSU
Manufacturer
XP POWER
Datasheet

Specifications of HUL175 LOOM KIT

Cable Assembly Type
Low Voltage
Cable Length
300mm
Svhc
No SVHC (18-Jun-2010)
Lead Length
300mm
Cable Length - Imperial
11.8"
Cable Length - Metric
300mm
Connector Type A
Receptacle
Connector Type B
Wire
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
175-300 Watts
HUL Series
Specification
Input
Output
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current • <1.5 mA at 230 VAC / 50 Hz
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Total Regulation
Over/Undershoot
Transient Response
Ripple & Noise
Overvoltage Protection • 130% on output 1 only, recycle input to
Overtemperature
Protection
Overload Protection
Short Circuit Protection • Trip and restart (Hiccup mode)
Temperature
Coefficient
Remote Sense
Remote On/Off
Fan Output
• 90-132 VAC, 180-264 VAC (auto-ranging)
• 47-63 Hz
• HUL175: 4.4 A max at 115 VAC,
• 35 A at 115 VAC, 70 A max at 264 VAC
• Passive PFC, meets EN6100-3-2, -3
• See tables
• ±5% on output 1
• ±1% max for single/main output
• See tables & note 1 for 175 W model
• 1 s max
• 20 ms max
• >15 ms at 115 VAC
• ±1% max for single output models,
• <5% max
• 5% max deviation, recovery to within
• 1% pk-pk (50 mV max for 3.3 V output)
• Shuts down when ambient temperature
• 110-135% of total power, auto recovery
• ±0.1%/°C
• HUL175 only. Compensates for 0.5 V drop
• On = Logic High or Open
• 12 V, 300 mA
2.2 A max at 230 VAC
HUL200: 5.0 A max at 115 VAC,
2.5 A max at 230 VAC
HUL300: 6.3 A max at 115 VAC,
3.15 A max at 230 VAC
+25 °C cold start
±5% for auxiliary outputs
±5% max for multiple output models
1% in 500 µs for a 50% load change
reset
exceeds +85 °C, auto recovery
on 3.3 V output
Off = Logic Low or Short
Not available on HUL175
General
Environmental
EMC & Safety
Efficiency
Isolation
Switching Frequency
Power Density
Power Fail Detect
MTBF
Operating Temperature • 0 °C to +60 °C, derate linearly from 100%
Cooling
Operating Humidity
Storage Temperature
Operating Altitude
Shock
Vibration
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
Compact Size, Low Profile
Up to 5.85 W/in
Single & Multiple Outputs
Convection-cooled Ratings
Remote On/Off
Power Fail Detect
12 V Fan Supply
• 80% typical
• 3000 VAC Input to Output,
• 42 kHz typical
• HUL175: 4.51 W/In
• On = Logic high 100-500 ms after outputs
• 100 kHrs per MIL-HDBK-217F
• See notes
• 5-90% RH, non-condensing
• -20 °C to +85 °C
• 3000 m
• 15 g (non-operation), 11 ms (half sine
• 10-55 Hz (non-operation) 2 g, sweep time
• EN55022 and FCC, level B
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, level 4 Perf Criteria A
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 10 V Perf Criteria A
• EN61000-4-11, 30% 10 ms,
• EN60950, UL60950, CSA22.2 No. 950
3
HUL300: 4.41 W/In
with regulation
Fail = Logic low at least 1 ms prior to loss
of output
at +40 °C to 50% at +60 °C
(level A - 300 W) conducted
70% 100 ms, 95% 5000 ms,
Perf Criteria A, B, B
per cUL, CE Mark
Power Density
1500 VAC Input to Ground,
500 VAC Output to Ground
wave), 3 times for each axis
3 mins, 60 mins/axis
xppower.com
3
3
, HUL200: 5.85 W/In
3
,

Related parts for HUL175 LOOM KIT

HUL175 LOOM KIT Summary of contents

Page 1

Watts HUL Series Specification Input Input Voltage • 90-132 VAC, 180-264 VAC (auto-ranging) Input Frequency • 47-63 Hz Input Current • HUL175: 4.4 A max at 115 VAC, 2.2 A max at 230 VAC HUL200: 5.0 A max at ...

Page 2

... Cable harnesses with 11.81” (300 mm) wire available, order part HUL175 LOOM KIT 6. Covers are available separately. Order part HUL175 COVER 7. Max penetration of screws 0.12” ...

Page 3

... Output is turned off by taking the Remote On/Off pin low (connect to Return). 8. Cable harnesses with 11.81” ( 300 mm) wire available, order part number HUL200 LOOM-S for single output models, HUL200 LOOM-D for dual output models, HUL200 LOOM-T for triple output models or HUL200 LOOM-Q for quad output models. ...

Page 4

... open collector output. Low = normal operation. 11.81” Cable harnesses with 300 mm) wire available, order part number HUL300 LOOM-S for single output models, HUL300 LOOM-D for dual output models, HUL300 LOOM-T for triple output models or HUL300 LOOM-Q for quad output models. For mating connectors only, order part HUL300 CON KT†. ...

Related keywords