1566440000 Weidmuller, 1566440000 Datasheet - Page 27

no-image

1566440000

Manufacturer Part Number
1566440000
Description
CONN FMALE DSTV-HD 64 SIZE8 GOLD
Manufacturer
Weidmuller
Series
Rockstar® DSTV-HDr
Datasheet

Specifications of 1566440000

Connector Type
Insert
Gender
Female
Number Of Positions
64+Ground
Size
8
Termination Style
Terminal Block, Curved - Screw
Voltage Rating
250V
Current Rating
10A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Contact Type
-
Influencing factors:
Rated impulse withstand voltage
The rated impulse withstand voltage is
derived from:
• Phase-to-earth voltage (the nominal
• Overvoltage category
The overvoltage categories are
defined
in accordance with international standard
DIN EN 60664-1 (for electrical equipment
fed directly from the low voltage network).
Overvoltage category I
• Equipment that is intended to be
Table 1: Three-phase 4 or 3-conductor a.c. systems
connected to the permanent electrical
installation of a building. Measures
to limit transient overvoltages to the
specific level are taken outside the
equipment, either in the permanent
installation or between the permanent
installation and the equipment.
voltage of the network, taking all
networks into account)
Nominal voltage of power
supply systems
1000
110
120
127
150
208
220
230
240
300
380
400
415
440
480
500
575
600
660
690
720
830
960
[V]
60
for conductor-cond. insulat.
all Systems
1000
1000
125
160
200
250
320
400
500
500
630
630
630
800
[V]
63
3-phase 4-conductor systems
with earthed neutral cond. [V]
Overvoltage category II
• equipment to be connected to the
Overvoltage category III
• equipment that is part of the perma-
Overvoltage category IV
• Equiment for use at or in the proximity
permanent electrical installation of a
building e.g. household appliances,
portable tools and similar loads.
nent electrical installation and other
equipment where a higher degree of
availability is expected e.g. distribution
boards, circuit-breakers, wiring
systems (IEV 826-06-01, including
cables, busbars, junction boxes,
switches, power sockets) in the
permanent installation, and equipment
for industrial use and some other
equipment, e.g. stationary motors
with permanent connections to the
permanent installation.
of the incoming supply point of the
electrical installations of buildings
upstream of the main distribution board
e.g. electricity meters, circuit-breakers
and ripple control units.
125
160
250
250
320
400
400
500
630
32
80
for conductor-earth insulation
unearthed or cond. earthed [V]
3-phase 4-conductor systems
1000
1000
125
160
200
250
320
400
500
500
630
630
630
800
63
Pollution severity categories:
Pollution severity category 1
• No pollution, or only dry, non-
Pollution severity category 2
• Non-conductive pollution only;
Pollution severity category 3
• Conductive pollution, or dry, non-
Pollution severity category 4
• Contamination results in constant
The dimensioning of clearances and
creepage distances, and hence the
rating data for electromechanical
products (terminals, terminal strips,
PCB terminals and plug-in connectors)
is based on pollution severity 3 and
overvoltage category III, taking account
of all network types.
conductive pollution that has no
influence.
occasional condensation may cause
temporary conductivity.
conductive pollution that is liable to
be rendered conductive through
condensation.
conductivity, e.g. caused by conduc-
tive dust, rain or snow.
Technical data
A.17
A