ZEN10C1DTDV1 Omron, ZEN10C1DTDV1 Datasheet - Page 29

Programmable Logic Controller

ZEN10C1DTDV1

Manufacturer Part Number
ZEN10C1DTDV1
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet

Specifications of ZEN10C1DTDV1

Peak Reflow Compatible (260 C)
No
Signal Input Type
24 VDC
Output Type
Transistor
Supply Voltage
24VDC
Supply Voltage Max
24VDC
No. Of Digital Inputs
6
Mounting Type
DIN Rail/ Bolt-on
No. Of Digital Outputs
4
Rohs Compliant
No
Approval Categories
UL, CE
Leaded Process Compatible
No
For Use With
ZEN Series Logic Controllers
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Precautions when Switching from Previous Units
• Previous models of Expansion I/O Units cannot be connected to V2 CPU Units.
• ZEN-8E1@R Expansion I/O Units with relay outputs need to be connected to a power supply.
• A ZEN-@C@D@-D-V2 CPU Unit with DC power supply cannot be connected to an Expansion I/O Unit with AC inputs.
• When connecting Expansion I/O Units with DC inputs to a CPU Unit with an AC power supply, the burst noise immunity will be 1 kV (IEC 61000-
• There is no change to the 8 A per contact for relay output, but the total output for all contacts must be as follows:
• Always use the ZEN-SOFT01-V4 Support Software for V2 CPU Units.
• Input wiring for CPU Units with DC power supplies differs from that for Pre-V1 CPU Units. Refer to the following diagrams.
Ratings and Specifications
CPU Units
Rated power
supply voltage
Power
consumption
Inrush current Models with AC
DC inputs
I0 to I3
(See note 1.)
Negative ( ) COM Wiring
4-4).
COM wiring depends on whether a negative common or positive common is being used.
Changes
Units with 10 I/O Points: 20 A max. (15 A max. for Communications-type CPU Units)
Units with 20 I/O Points: 40 A max.
Expansion I/O Units:
24 VDC
+
CPU Unit with 10 I/O Points
COM
Item
Models with DC
power supply
Models with AC
power supply
Models with DC
power supply
power supply
Models with DC
power supply
Input impedance
ON voltage
Input common
COM wiring required.
Analog inputs possible.
V2 and V1 CPU Units
20 A max.
Input
devices
10.8 to 28.8 VDC
See Ratings on page 7.
Models with 10 I/O points: 4.5 A max.
Models with 20 I/O points: 4.5 A max.
Models with 10 I/O points: 30 A max.
Models with 20 I/O points: 30 A max.
5.3 k
8 VDC min.
Independent common terminal
Note: I4 and I5 (Ia and Ib for CPU Units with 20 I/O
points) cannot be used as analog input terminals.
Positive (+) COM Wiring
24 VDC
CPU Unit with 10 I/O Points
+
V2 Units
COM
COM wiring required.
Programmable Relay
Input
devices
The input circuit common terminal is connected
internally to the negative ( ) side of the power
supply circuit.
20.4 to 26.4 VDC
30 VA max.
(with 3 Expansion I/O Units connected)
6.5 W max.
(with 3 Expansion I/O Units connected)
40 A max.
20 A max.
5 k
16 VDC min.
V1 Units
24 VDC
ZEN V2 Units
+
CPU Unit with 10 I/O Points
Pre-V1 CPU Units
NC
4.8 k
Internally connected to
power supply terminal
Analog inputs possible.
Pre-V1 Units
Input
devices
29