E5AN-HSS2HBMD-500 Omron, E5AN-HSS2HBMD-500 Datasheet - Page 9

no-image

E5AN-HSS2HBMD-500

Manufacturer Part Number
E5AN-HSS2HBMD-500
Description
CONTROLLER TEMP 24VAC/DC
Manufacturer
Omron
Datasheet

Specifications of E5AN-HSS2HBMD-500

Thermocouple Type
B, E, J, K, L, N, R, S, T, W, PLII
Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Output Voltage Max
250VAC
Output Voltage Min
75VAC
Svhc
No SVHC (15-Dec-2010)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
USB-Serial Conversion Cable
Note: A driver must be installed in the personal computer. Refer to
Communications Specifications
Note: The baud rate, data bit length, stop bit length, and vertical parity
Applicable OS
Applicable software
Applicable models
USB interface standard
DTE speed
Connector specifications
Power supply
Power supply voltage
Current consumption
Ambient operating tempera-
ture
Ambient operating humidity 10% to 80%
Storage temperature
Storage humidity
Altitude
Weight
Transmission line
connection method
Communications
Synchronization
method
Protocol
Baud rate
Transmission code
Data bit length ✽
Stop bit length ✽
Error detection
Flow control
Interface
Retry function
Communications
buffer
Communications
response wait time
installation information in the operation manual for the
Conversion Cable.
can be individually set using the Communications Setting
Level.
RS-485, RS-422: Multipoint
RS-232C: Point-to-point
RS-485 (two-wire, half duplex)
RS-422 (four-wire, half duplex) or RS-232C
Start-stop synchronization
CompoWay/F, SYSWAY, or Modbus
1200, 2400, 4800, 9600, 19200, 38400, or
57600 bps
ASCII (CompoWay/F, SYSWAY)
RTU (Modbus)
7 or 8 bits
1 or 2 bits
Vertical parity (none, even, odd)
Frame check sequence (FCS) with SYSWAY
Block check character (BCC) with
CompoWay/F or CRC-16 Modbus
None
RS-485, RS-422, or RS-232C
None
217 bytes
0 to 99 ms
Default: 20 ms
Windows 2000, XP, or Vista
Thermo Mini, CX-Thermo version
4.0 or higher
E5AN/E5EN/E5CN/E5CN-U/
E5AN-H/E5EN-H/E5CN-H
Conforms to USB Specification 1.1.
38400 bps
Computer: USB (type A plug)
Temperature Controller: Setup
Tool port (on bottom of Controller)
Bus power (Supplied from USB
host controller.)
5 VDC
70 mA
0 to 55°C (with no condensation or
icing)
−20 to 60°C (with no condensation
or icing)
10% to 80%
2,000 m max.
Approx. 100 g
Advanced Digital Temperature Controller
Current Transformer (Order Separately)
Ratings
USB-Infrared Conversion Cable
Note: A driver must be installed in the personal computer. Refer to
Heater Burnout Alarms, SSR Failure
Alarms, and Heater Overcurrent Alarms
✽1. For heater burnout alarms, the heater current will be measured when
✽2. For SSR failure alarms, the heater current will be measured when the
✽3. For heater overcurrent alarms, the heater current will be measured
Dielectric strength
Vibration resistance
Weight
Accessories (E54-CT3 only) Armatures (2)
Applicable OS
Applicable software
Applicable models
USB interface standard
DTE speed
Connector specifications
Power supply
Power supply voltage
Current consumption
Ambient operating tempera-
ture
Ambient operating humidity 10% to 80%
Storage temperature
Storage humidity
Altitude
Weight
CT input
(for heater current detec-
tion)
Maximum heater current
Input current indication
accuracy
Heater burnout alarm set-
ting range ✽1
SSR failure alarm setting
range ✽2
Heater overcurrent alarm
setting range ✽3
the control output is ON, and the output assigned to the alarm 1
function will turn ON if the heater current is lower than the set value
(i.e., heater burnout detection current value).
control output is OFF, and the output assigned to the alarm 1 function
will turn ON if the heater current is higher than the set value (i.e., SSR
failure detection current value).
when the control output is ON, and the output assigned to the alarm 1
function will turn ON if the heater current is higher than the set value
(i.e., heater overcurrent detection current value).
installation information in the operation manual for the
Conversion Cable.
E5AN-H/E5EN-H
Models with detection for single-phase
heaters: One input
Models with detection for single-phase
or three-phase heaters: Two inputs
50 A AC
±5% FS ±1 digit max.
0.1 to 49.9 A (in units of 0.1 A)
Minimum detection ON time: 100 ms
0.1 to 49.9 A (in units of 0.1 A)
Minimum detection OFF time: 100 ms
0.1 to 49.9 A (in units of 0.1 A)
Minimum detection ON time: 100 ms
1,000 VAC for 1 min
50 Hz, 98 m/s
E54-CT1: Approx. 11.5 g,
E54-CT3: Approx. 50 g
Plugs (2)
Windows 2000, XP, or Vista
Thermo Mini, CX-Thermo version
4.0 or higher
E5AN-H/E5EN-H
Conforms to USB Specification 1.1.
38400 bps
Computer: USB (type A plug)
Temperature Controller: Infrared
port (on front of Controller)
Bus power (Supplied from USB
host controller.)
5 VDC
80 mA
0 to 55°C (with no condensation or
icing)
−20 to 60°C (with no condensation
or icing)
10% to 80%
2,000 m max.
Approx. 130 g (with mounting
adaptor)
2
9

Related parts for E5AN-HSS2HBMD-500