T1641100 Red Lion Controls, T1641100 Datasheet - Page 11

PID TEMPERATURE CONTROLLER, ANALOG

T1641100

Manufacturer Part Number
T1641100
Description
PID TEMPERATURE CONTROLLER, ANALOG
Manufacturer
Red Lion Controls
Type
Temperaturer
Datasheets

Specifications of T1641100

Thermocouple Type
T, E, J, K, R, S, B, N, C, Linear MV
Operating Temperature Max
50°C
Operating Temperature Min
0°C
Output Voltage Max
10VDC
Output Voltage Min
0V
Accuracy
0.3%
Approval
RoHS Compliant
Brand/series
T16 Series
Dimensions
49.5mmW×49.5mmH×115.3mmD
Enclosure Rating
IP65
Input Type
RTD/Thermocouple
Ip Rating
IP65
Memory
EEPROM
Mounting Type
Panel
Output Type
Analog
Power, Rating
8 VA
Primary Type
Controller
Special Features
EEPROM
Standards
cURus, CE
Termination
Screw
Voltage, Supply
85 to 250 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
types, this has no effect. If changed, adjust related parameter values, as the
controller does not automatically convert them.
values, and related parameters. For Linear Resistance inputs rLIN, the same
parameter selections apply in ohms or tenths of an ohm. For mV inputs LIN,
only hundredths of a mV resolution is available.
noise and actual process changes. If the signal is varying too greatly due to
measurement noise, increase the filter value. If the fastest controller response is
needed, decrease the filter value.
amount. This is useful in applications in which the sensor cannot provide the
actual temperature signal due to mounting constraints, inaccuracy, etc.
7.1 MODULE 1 - I
tc-j
tYPE
Select the input type that corresponds to the input sensor.
SCAL
Select either degrees Fahrenheit or Celsius. For linear mV and ohms input
dCPt
Select whole degrees, or tenths of degrees for Temperature display, Setpoint
FLtr
The filter is an adaptive digital filter that discriminates between measurement
SHft
This value offsets the controller’s temperature display value by the entered
°F
0
1
0
SELECTION TYPE
0
0. 0 0
0
-999
tc-t
tc-E
tc-*
tc-K
tc-r
tc-S
tc-b
to
= least to
0. 0
for mV inputs
°F
°C
to
DECIMAL RESOLUTION
TEMPERATURE SCALE
for temperature and resistance inputs
9999
R TC
T TC
E TC
K TC
S TC
B TC
J TC
Fahrenheit
Celsius
DIGITAL FILTERING
SHIFT/OFFSET
INPUT TYPE
4
degrees
= most
SELECTION
tc-N
tc-C
r385
r392
r672
rLIN
LIN
N TC
C TC
Linear mV
RTD 385
RTD 392
RTD 672
Linear Ohms
NPUT
TYPE
PARAMETER MENU
P
ARAMETERS
11
setting range of the setpoint. Set the limit so that the setpoint value cannot be
set below the safe operating area of the process.
setting range of the setpoint. Set the limit so that the setpoint value cannot be
set above the safe operating area of the process.
SELECTION
available only on models with alarms), when the User terminal 1 is connected
(pulled low) to Common terminal 8.
No Function: No function is performed.
Program Lock: The Configuration Loop is locked, as long as activated
Integral Action Lock: The integral action of the PID computation is disabled
Auto/Manual Select: This function selects (maintained action) Automatic
Setpoint 1 or 2 Select: This function selects (maintained action) Setpoint
Setpoint Ramp Disable: The setpoint ramping feature is disabled, as long as
Reset Alarms: Active alarms are reset, as long as activated (maintained action).
SPLO
The controller has a programmable low setpoint limit value to restrict the
SPHI
9999
The controller has a programmable high setpoint limit value to restrict the
InPt
PLOC
NONE
PLOC
ILOC
trnF
The controller performs the selected User Input function (User Input
(maintained action).
(frozen), as long as activated (maintained action).
(open) or Manual Control (activated).
1(open) or Setpoint 2 (activated) as the active setpoint.
activated (maintained action). Any time the user input is activated with a
ramp in process, ramping is aborted.
Active alarms are reset until the alarm condition is cleared and triggered
again (momentary action).
(
0
"%# # &
No Function
Program Lock
Integral Action Lock
Auto/Manual Select
-999
-999
FUNCTION
USER INPUT FUNCTION (OPTIONAL)
) T16 O
to
to
SETPOINT HIGH LIMIT
SETPOINT LOW LIMIT
9999
9999
SELECTION
SPrP
ALrS
SPt
NLY
Setpoint 1 or 2 Select
Setpoint Ramp Disable
Reset Both Alarms
FUNCTION

Related parts for T1641100