PSR37-600-70 ABB, PSR37-600-70 Datasheet - Page 36

no-image

PSR37-600-70

Manufacturer Part Number
PSR37-600-70
Description
SOFTSTARTER,240VAC,37A
Manufacturer
ABB
Datasheet

Specifications of PSR37-600-70

Power Rating
18.5kW
Current Rating
37A
Svhc
No SVHC (18-Jun-2010)
Control Voltage Ac Max
240V
Control Voltage Ac Min
100V
External Depth
153mm
External Length / Height
172mm
External Width
54mm
Rohs Compliant
Yes
Operating Temperature Max
60°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Major possible settings and the displayed text and the set default values
Description
Setting current for overload, locked rotor etc.
Time for start ramp
Time for stop ramp
Initial voltage for start ramp
End voltage for stop ramp
Step down voltage
Level of the current limit.
Selection of Kick start
Level of Kick start if selected
Time for Kick start if selected
Selectable range for start ramp
Selectable range for stop ramp
Overload protection
Overload Class
Overload Class, Dual type, Start Class
Overload Class, Dual type, Run Class
Type of operation for overload protection
Locked rotor protection
Trip level for locked rotor protection
Trip time for locked rotor protection
Type of operation for locked rotor protection
Underload protection
Trip level for Underload protection
Trip time for Underload protection
Type of operation for Underload protection
Phase imbalance protection
Trip level for phase imbalance protection
Type of operation for phase imbalance protection
High current protection
Type of operation for high current protection
Phase reversal protection
Type of operation for phase reversal protection
PTC protection
Type of operation for PTC protection
An external Bypass contactor is used
High current warning
Trip level for high current warning
Low current warning
Trip level for low current warning
Overload warning
Trip level for overload warning
Thyristor overload warning
Type of operation for phase loss fault
Type of operation for by-pass doesn’t close
Type of operation for by-pass doesn’t open
Type of operation for fieldbus fault
Type of operation for frequency fault
Type of operation for heat sink over temperature fault
Type of operation for thyristor short circuit fault
Function of programmable input In_0
Function of programmable input In_1
Function of programmable relay output K4
Function of programmable relay output K5
Function of programmable relay output K6
Control of the softstarter with fieldbus
Number of sequences for sequence start.
Language to use on display
Password for display
Start mode
Stop mode
Torque limit
Analog output
Analog output, reference
Analog output, type of value
36
1SFC132004C0201, Ed. 5
Softstarters
Type PST30 ... 300 and PSTB370 ... 1050
Technical data/Settings
Text on display Values on display
Setting I
Start Ramp
Stop Ramp
Init Volt
End Volt
Step Down
Current Lim
Kick Start
Kick Level
Kick Time
Start Range
Stop Range
Overload
OL Class
OL Class S
OL Class R
OL Op
Locked Rotor
Lock R Lev
Lock R Time
Lock R Op
Underload
Underl Lev
Underl Time
Underl Op
Phase Imb
Ph Imb Lev
Ph Imb Op
High I
High I Op
Phase Rev
Ph Rev Op
PTC
PTC Op
Ext ByPass
Warn I=High
Wa I=H Lev
Warn I=Low
Wa I=L Lev
Warn OL
Wa OL Lev
Warn SCR OL
Ph Loss Op
BP open Op
BP closed Op
FB Fault Op
Freq F Op
HS Temp Op
SCR SC Op
In0
In1
Relay K4
Relay K5
Relay K6
Fieldb Ctrl
No of Seq
Language
Password
Start Mode
Stop Mode
Torque limit
Analogue Out
Anl Ref
Anl Type
(Eng)
e
9,0 ...1207 A divided into 19 overlapping ranges.
1 ... 30 s, 1 ... 120 s (Range depends on Start Range)
0 ... 30 s, 0 ... 120 s (Range depends on Stop Range)
30 ... 70 %
30 ... 70 %
30 ...100 %
1.5 ... 7.0 x I
Yes, No
50 ... 100 %
0.1 ... 1.5 s
1 ... 30 s, 1...120 s
0 ... 30 s, 0 ... 120 s
No, Normal, Dual
10 A, 10, 20, 30
10A, 10, 20, 30
10A, 10, 20, 30
Stop-M, Stop-A, Ind
Yes, No
0.5 ... 8.0 x I
0.2 ... 10 s
Stop-M, Stop-A, Ind
Yes, No
0.4 ... 0.8 x I
1 ... 30 s
Stop-M, Stop-A, Ind
Yes, No
10 ... 80 %
Stop-M, Stop-A, Ind
Yes, No
Stop-M, Stop-A, Ind
Yes, No
Stop-M, Stop-A, Ind
Yes, No
Stop-M, Stop-A
Yes, No
Yes, No
0.5 ... 5.0 x I
Yes, No
0.4 ...1.0 x I
Yes, No
40 ... 99 %
Yes, No
Stop-M, Stop-A
Stop-M, Stop-A
Stop-M, Stop-A
Stop-M, Stop-A
Stop-M, Stop-A
Stop-M, Stop-A
Stop-M, Stop-A
None, Reset, Enable, Jog, DOL, Start 2, FB-Dis
None, Reset, Enable, Jog, DOL, Start 3, FB-Dis
Run, TOR, Event
Run, TOR, Event
Run, TOR, Event
Yes, No
No, 2, 3
US/UK, FI, SE, PT, NL, IT, FR, ES, DE, CN, RU, TR, PL, CZ
No, 1 ... 255
Volt, Torque
Volt, Torque
20 ... 200 %
Yes, No
0 ...10 V, 0 ... 20 mA, 4 ... 20 mA
I Amp, U Volt, P kW, P hp, Q kVAr, S kVA, TmpMot, TmpSCR, cosPhi
e
e
e
e
e
Default value
See table, page 40
10 s
0 s
30 %
30 %
100 %
4.0 x I
No
50 %
0.2
1 ... 30 s
0 ... 30 s
Normal
10
10
10
Stop-M
No
4,0 x I
1.0 s
Stop-M
No
0.5 x I
10 s
Stop-M
No
80 %
Stop-M
No
Stop-M
No
Stop-M
No
Stop-M
No
No
1.2 x I
No
0.8 x I
No
90 %
No
Stop-M
Stop-M
Stop-M
Stop-M
Stop-M
Stop-M
Stop-M
Reset
Reset
Run
TOR
Event
No
No
US/UK
Volt
Volt
150 %
No
4 ...20 mA
I Amp
e
e
e
e
e