PSR6-600-70 ABB, PSR6-600-70 Datasheet

no-image

PSR6-600-70

Manufacturer Part Number
PSR6-600-70
Description
SOFTSTARTER,100-240VAC,6A
Manufacturer
ABB
Datasheet

Specifications of PSR6-600-70

Power Rating
3kW
Current Rating
6A
Svhc
No SVHC (18-Jun-2010)
Control Voltage Ac Max
240V
Control Voltage Ac Min
100V
External Depth
114mm
External Length / Height
120mm
External Width
45mm
Rohs Compliant
Yes
Operating Temperature Max
60°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Main Catalogue
Catalogue 1SFC132004C0201, Edition 7 February 2010
Latest updated
2010-02-23
not printed, only
in PDF-format
Softstarters
Type PSR
Type PSS
Type PST/PSTB
(1SFC132198F0001)

Related parts for PSR6-600-70

PSR6-600-70 Summary of contents

Page 1

... Main Catalogue Latest updated 2010-02-23 not printed, only in PDF-format Catalogue 1SFC132004C0201, Edition 7 February 2010 Softstarters Type PSR Type PSS Type PST/PSTB (1SFC132198F0001) ...

Page 2

... These signals can then be used as input to a PLC or an analog meter. Type PSR Softstarter The latest addition to the ABB softstarter range is the compact PSR softstarter. This new softstarter has a compact, attractive design and is ideal for installation in places where space is limited and where there is a demand for easy installation ...

Page 3

... Type/Order code. Packing: All softstarters and most of the accessories are delivered in an individual packing. Some of the accessories are packed together in batches of ”n” pieces (see ordering ”Pack items, please order the total amount corresponding to a multiple of the number in the packing ...

Page 4

... The financial consequences are considerable: every techni- cal problem and every breakdown, costs money – in terms of repairs as well as lost production. The easy solution to all of these problems is to install an ABB Softstarter type PSR, PSS or PST. With ABB Softstarters possible to start and stop smoothly while keeping mechanical and electrical stresses to a minimum ...

Page 5

... FieldBusPlug (FBP), you can decide at any time which bus system to select within the ABB FBP range. The interface between the PST Softstarter and the ABB FBP is always the same, independent of size and delivery date. • LCD display: With 14 languages, a menu system similar to your mobile phone, preprogrammed application settings and automatic status and event logging, it couldn’ ...

Page 6

... A OS32GD OS32GD OS63GD OS125GD A26 A30 A40 A50 TA25DU TA25DU TA42DU TA75DU Built-in Built-in Built-in Built- PSR3 PSR6 PSR9 PSR12 PSR12 PSR16 PSR25 PSR25 PSR30 PSR30 PSR37 PSR37 PSR45 PSR45 PSR60 PSR45 PSR60 PSR72 PSR60 PSR72 PSR85 PSR105 PSR85 PSR105 ...

Page 7

... Softstarters Type PSR Overview and description PSR60 ... PSR105 Softstarter , Type PSR60 PSR72 PSR85 PSR105 105 59 104 400V, 40 °C Manual motor starter, Type MS495 MS495 MS495 — Fuse protection 400 V, 50 kA, gG Fuse 125 A 200 A 200 A 250 A Switch fuse , Type OS125GD OS250GD ...

Page 8

... PSR105-MS495 Suitable for all sizes. See page 32 - 34. PSLW PSR-FAN FieldBusPlug 8 1SFC132004C0201, Ed. 5 IEC 400 V 500 V Max rated motor P P current Type 100-240 1.5 2.2 3.9 PSR3-600- 6.8 PSR6-600- PSR9-600-70 5.5 5.5 12 PSR12-600-70 7.5 7.5 16 PSR16-600- PSR25-600-70 15 18.5 30 PSR30-600-70 18 PSR37-600-70 PSR45-600- ...

Page 9

... PSR45 46.2 15 PSR60 59.4 20 PSR72 68 20 PSR85 80 25 PSR105 104 30 PSR6 PSR9 PSR12 PSR16 PSR25 PSR30 PSR37 PSR45 PSR60 PSR72 PSR85 PSR105 PSR6 PSR9 PSR12 PSR16 PSR25 PSR30 PSR37 PSR45 PSR60 PSR72 PSR85 PSR105 6 for 6 sec. r during 6 s) See table on page 6 for details. ...

Page 10

... Type OS160RD0380 OS160RD0380 OS160RD0380 , Type A30 A40 A50 , Type TA25DU TA42DU TA75DU , Type A16 A26 A26 , Type PSCT-40 PSCT-50 PSCT-60 1 turn 1 turn 1 turn www.abb.com/lowvoltage. PSS50/85 ... PSS72/124 PSS50/85 PSS60/105 PSS72/124 T2S160 T2S160 T2S160 170M1369 170M1370 170M1371 OS160RD0380 OS160RD0380 OS160RD0380 ...

Page 11

... How to select correct size By using the guide beside, you can quickly select a suitable softstarter for the most common applications more precise selection is required, you can use Prosoft, a selection software available at www.abb.com/lowvoltage. PSS175/300... PSS300/515 PSS142/245 PSS175/300 75 90 142 175 100 ...

Page 12

... The softstarter range PSS18/30 ... PSS300/515 is a very flexible solution suitable for most applications and for replacements of Star- Delta starters. Since the unit can be connected inside the motor delta (compare the connection for standard Star-Delta starters), the current through the softstarter is reduced will then be possible, for example, to run a 100 A motor using PSS Softstarter ...

Page 13

... Softstarters Type PSS18/30 ... PSS300/515 Different sizes of PSS, from left PSS175/300-500L, PSS85/147-500L, PSS50/85-500L and in the front PSS18/30-500L. Settings PSS18/30 … PSS300/515 ini 3 Start Ramp time START = 1 ... 30 sec 1 Ramp time STOP = 0 ... 30 sec 2 3 Initial voltage U used fixed (also set ”end voltage”) ...

Page 14

... Softstarters Type PSS18/30 ... PSS300/515 Normal starts, class 10 – In-Line, Ordering details PSS18/30 ... PSS300/515 230 – 500 V Motor power 400 7.5 15 18.5 PSS18/30-500 ... 44/76-500 132 160 PSS50/85-500 ...72/124-500 PSS18/30-690 ... 72/124-690 400 – 690 V Motor power 400 7 PSS85/147-500 ...142/245-500 PSS85/147-690 ...142/245-690 ...

Page 15

... Softstarters Type PSS18/30 ... PSS300/515 Normal starts, class 10 – Inside Delta, Ordering details PSS18/30 ... PSS300/515 230 – 500 V Motor power 400 V 500 18 PSS18/30-500 ... 44/76-500 110 132 160 160 200 220 295 257 355 PSS50/85-500 ...72/124-500 PSS18/30-690 ... 72/124-690 400 – 690 V Motor power ...

Page 16

... Softstarters Type PSS30/52 ... PSS300/515 Heavy duty starts, class 30 – In-Line, Ordering details PSS30/52 ... PSS300/515 230 – 500 V Motor power 400 7.5 15 18.5 PSS30/52-500 ... 44/76-500 132 PSS50/85-500 ...72/124-500 400 – 690 V PSS18/30-690 ... 72/124-690 Motor power 400 7 PSS85/147-500 ...142/245-500 45 PSS85/147-690 ...142/245-690 ...

Page 17

... Softstarters Type PSS30/52 ... PSS300/515 Heavy duty starts, class 30 – Inside Delta, Ordering details PSS30/52 ... PSS300/515 230 – 500 V Motor power 400 V 500 18 PSS30/52-500 ... 44/76-500 110 132 160 160 200 220 295 PSS50/85-500 ...72/124-500 400 – 690 V PSS18/30-690 ... 72/124-690 Motor power 400 V ...

Page 18

... Softstarters Accessories for type PSS18/30 ... PSS300/515 Ordering details Current transformer for current limit function To be connected to terminals 11 and 12 on the softstarter. The setting range (1.5 – 4) corresponds to a multiple of the transformer ratio. Technical data below shows transformer ratio and number of turns for the primary winding. ...

Page 19

... Softstarters Type PSS18/30 ... PSS300/515 Technical data Rated insulation voltage Rated operational voltage Starting capacity at max. rated current Number of starts per hour Overload capability Overload class Service factor Ambient temperature During operation During storage Maximum altitud 4) Degree of protection Main circuit Supply and control circuit ...

Page 20

... Hole diameter mm Tightening torque Nm (recommended) Supply and control circuit Connection clamp Solid/Stranded Solid/Stranded Tightening torque Nm (recommended) Fuse ratings and power losses Recommended Max power loss at ABB Overload protection rated I For Current without by-pass Softstarter range 2) Type Type A W PSS18/ 6–18 65 PSS30/ 10– ...

Page 21

... PSS60/105 15 56 PSS72/124 20 67 PSS85/147 25 85 PSS105/181 30 105 PSS142/245 40 125 PSS175/300 50 156 PSS250/430 75 225 PSS300/515 75 248 3-phase motor rating - Inside Delta Softstarters Motor power P (hp) and full load current FLA, ( 200V / 208V Type hp A PSS18/30 7.5 30 PSS30/ PSS37/ PSS44/ PSS50/ PSS60/105 30 ...

Page 22

... Semiconductor fuses, Bussmann, Type , Type OS160RD0380 OS160RD0380 OS160RD0380 OS160RD0380 , Type A40 A50 A50 A63 Built-in Built-in Built-in Built-in , Type A26 A26 A30 A40 Integrated Integrated Integrated Integrated www.abb.com/lowvoltage. PST85 ... PST142 PST72 PST85 PST105 PST142 105 142 100 68 80 104 130 T2S160 T2S160 ...

Page 23

... How to select correct size By using the guide beside, you can quickly select a suitable softstarter for the most common applications more precise selection is required, you can use Prosoft, a selection software available at www.abb.com/lowvoltage. PSTB370 ... 470 PSTB570 ... 1050 PSTB370 PSTB470 PSTB570 PSTB720 200 250 ...

Page 24

... Softstarters Type PST30 ... 300 and PSTB370 ... 1050 Application and description Application The PST range is a microprocessor based softstarter designed with the latest technology for soft start and soft stop of motors. The PST Soft- starter has several advanced motor protection features as standard. ...

Page 25

... Integrated by-pass contactor On the larger sizes (PSTB 370 ... PSTB1050), there is an ABB AF contactor integrated. This gives you advantages in terms of cost- saving, space saving and last but not least energy saving. With a by-pass contactor you can reduce the power losses during normal run more ...

Page 26

... Softstarters Type PST30 ... 300 and PSTB370 ... 1050 Normal starts, class 10 – In-Line, Ordering details PST30 ... PST300 230 – 600 V Motor power 400 18 PST30 ... PST72 110 132 160 400 – 690 V Motor power PST85 ... PST142 400 18 110 PST175 ... PST300 132 160 PSTB370 ... PSTB1050 with integrated by-pass 230 – ...

Page 27

... Softstarters Type PST30 ... 300 and PSTB370 ... 1050 Normal starts, class 10 – Inside Delta, Ordering details PST30 ... PST300 230 – 600 V Motor power 400 V 500 PST30 ... PST72 110 132 160 160 200 184 250 220 295 257 355 400 – 690 V Motor power PST85 ...

Page 28

... Softstarters Type PST37 ... 300 and PSTB370 ... 1050 Heavy duty starts, class 30 – In-Line, Ordering details PST37 ... PST300 230 – 600 V Motor power 400 18.5 22 PST30 ... PST72 110 132 400 – 690 V Motor power PST85 ... PST142 400 18 PST175 ... PST300 110 132 PSTB370 ... PSTB1050 with integrated by-pass 230 – ...

Page 29

... Softstarters Type PST37 ... 300 and PSTB370 ... 1050 Heavy duty starts, class 30 – Inside Delta, Ordering details PST37 ... PST300 230 – 600 V Motor power 400 V 500 PST30 ... PST72 110 132 160 160 200 184 250 220 295 400 – 690 V Motor power PST85 ... PST142 400 V 500 V ...

Page 30

... Softstarters Accessories for type PST30 ... 300 and PSTB370 ... 1050 Ordering details Cable connectors for Cu cables For PST85...300 you need 9 pieces if also using the terminals B1, B2, B3 for external by-pass contactor. For softstarter type PST85 …142 PST85 …142 PST175 …PSTB470 16-240 Cable connectors for Al and Cu cables For PST85 ...

Page 31

... To connect the PST Softstarter to a DeviceNet fieldbus system... you need specific software for PLC set-up, (EDS file) which is available at on the Softstarter pages. Look under the documentation-link named Software. If you need help or advice, please contact your local ABB office. Cable length ...

Page 32

... To connect the PST Softstarter to a DeviceNet fieldbus system... you need specific software for PLC set-up, (EDS file) which is available at on the Softstarter pages. Look under the documentation-link named Software. If you need help or advice, please contact your local ABB office. 32 1SFC132004C0201, Ed. 5 Cable ...

Page 33

... Profibus DP/V0 and DP/V1 FieldBusPlug PDP22-FBP PDQ22 is a member of the ABB FieldBusPlug family of bus connectors. It allows the connection four devices to Profibus DP by just using one Profibus node access. This allows a cost efficient device integration for devices that are located physically nearby. PDQ22 supports DP-V0 and DP-V1. The degree of protection is IP66 ...

Page 34

... To connect the PST Softstarter to a Profibus DP fieldbus system... you need specific software for PLC set-up, (GSD file) which is available at on the Softstarter pages. Look under the documentation-link named Software. If you need help or advice, please contact your local ABB office. 34 1SFC132004C0201, Ed. 5 Cable ...

Page 35

... Low current (underload) Overload trip Overtemp. thyristors (SCR) Start of several motors Possible to set up and start three different motors Field bus connection Connection for ABB FieldBusPlug PTC input Switch off resistance Switch on resistance External keypad Display Ambient temperature During operation During storage Degree of protection Valid for time and 50 % off time, with 3 ...

Page 36

... Softstarters Type PST30 ... 300 and PSTB370 ... 1050 Technical data/Settings Major possible settings and the displayed text and the set default values Description Setting current for overload, locked rotor etc. Time for start ramp Time for stop ramp Initial voltage for start ramp ...

Page 37

... Below you find a curve for each tripping class in cold state. Time (s) 10 000 1000 100 Tripping curves for electronic overload protection (Cold) ABB FieldBusPlug Controlling possibilities when using different field buses DeviceNet Simple control X (start/stop etc) X Complete control Simple status X information Detailed status ...

Page 38

... Tightening torque (recommended), Nm Supply and control circuit Connection clamp Solid/Stranded 2.5 2 Solid/Stranded 1.5 2 Tightening torque (recommended), Nm 0.5 Fuse ratings and power losses Recommended Max power loss ABB Overload protection at rated I For Current without by-pass softstarter range 2) Type Type A W PST PST30 Integrated 9 ...

Page 39

... PSTB470 150 480 PSTB570 200 590 PSTB720 250 720 PSTB840 300 840 PSTB1050 400 1062 3-phase motor rating - Inside Delta Softstarters Motor power, P (hp), and full load current FLA, ( 200V / 208V Type hp A PST30 10 42 PST37 15 54 PST44 20 72 PST50 ...

Page 40

... Dotted line denotes area covered by external keypad Dimensions 1SFC132004C0201, Ed. 5 Softstarter, type PSR3 ... PSR105 PSR3 ... 16 PSR25 ... 30 PSR37 ... 45 PSR60 ... 105 PSS ... -500 for 500 V PSS18/30 ... 44/76 PSS50/85 ... 72/124 PSS85/147 ... 142/245 PSS175/300 ... 300/515 PSS ... -690 for 690 V PSS18/30 ... 72/124 PSS85/147 ... 142/245 PSS175/300 ... 300/515 PST - all PST30 ...

Page 41

... Softstarters Type PSR3 ... PSR105 Dimensions PSR3 … 16 PSR25 … 30 PSR37 … (2.13’’ (1.73’’ (0.20’’) PSR60 ... 105 70 mm (2,76" (2.28") Dimensions in mm (and inches) 41 1SFC132004C0201, Ed. 5 ...

Page 42

... Softstarters Type PSS18/30 ... PSS300/515 Dimensions PSS18/30-500 … 44/76-500 PSS85/147-500 … 142/245-500 PSS85/147-690 … 142/245-690 Dimensions 1SFC132004C0201, Ed. 5 PSS50/85-500 … 72/124-500 PSS18/30-690 … 72/124-690 PSS 175/300-500 … 300/515-500 PSS 175/300-690 … 300/515-690 ...

Page 43

... Softstarters Type PST30 ... 300 and PSTB370 ... 1050 Dimensions PST30 ... 72 PST175 ... 300 Dimensions in mm PST85 ...142 PSTB370 ... 470 PST85 ...142 with marine kit PSTB570 ... 1050 43 1SFC132004C0201, Ed. 5 ...

Page 44

... Softstarters Type PSR3 ... PSR105 Diagrams PSR3 ...16 A) With MMS PSR25 ... 45 D) With MMS PSR60 ... 105 G) With MMS 44 1SFC132004C0201, Ed With MMS and auxiliary contact E) With MMS and auxiliary contact H) With MMS and auxiliary contact C) With fuses, contactor and O.L. F) With fuses, contactor and O.L. ...

Page 45

... Softstarters Type PSS18/30 ... PSS300/515 Diagrams PSS18/30…300/515 F6 Temperature monitor K5 Relay, actuated at full voltage (U = 100 Relay, fault signal T1 Control transformer T2 Current transformer V1-V6 Thyristor 45 1SFC132004C0201, Ed. 5 ...

Page 46

... Softstarters Type PST30 ... 300 and PSTB370 ... 1050 Diagrams PST30...300 PSTB370...1050 46 1SFC132004C0201, Ed. 5 ...

Page 47

... Type PSR, PSS, PST and PSTB Certifications, Approvals, Directives and Standards The table below shows the approvals and certifications for different softstarters. For approvals and/or certificates not listed below, please contact your local ABB sales office. Certifications and approvals Certifications Abbreviation ...

Page 48

Notes 48 1SFC132004C0201, Ed. 5 ...

Page 49

Notes 49 1SFC132004C0201, Ed. 5 ...

Page 50

Notes 50 1SFC132004C0201, Ed. 5 ...

Page 51

... Leader in power and automation technologies ABB (www.abb.com leader in power and automation techno- logies that enable utility and industry customers to improve per- formance while lowering environmental impact. The ABB Group of companies operates in around 100 countries and employs about 112 000 people. Division Automation Products ...

Page 52

... ABB AB Cewe-Control SE-721 61 Västerås, Sweden Telephone + Telefax +46 121 http://www.abb.com/lowvoltage ...