Y92F-90 Omron, Y92F-90 Datasheet

no-image

Y92F-90

Manufacturer Part Number
Y92F-90
Description
H5S TRACK MNT ADAPTER
Manufacturer
Omron
Type
Track Mounting Basesr
Datasheet

Specifications of Y92F-90

Rohs Compliant
YES
Accessory Type
Adapter - Panel Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
H5S-FB
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Y92F90
Easier, More Convenient Time Switches, with
New 4-circuit Output and Yearly Models in
Addition to 2-circuit Weekly Models
• Independent Day Keys provide easier operation.
• Temporary holiday setting function makes it easy to turn OFF
• Settings can be made even with the Time Switch turned OFF.
• Test mode enables easy program checking.
• Complies with EMC Directives, UL/CSA, and other safety
• Includes summer time (DST) adjustment.
• Set value can be changed both upward and downward for
• Integrated temperature compensation circuit helps keep
• Includes time counter and total counter functions with alarm
• Bank function allows program switching by an external input.
• New 4-circuit output models with a compact, 72 × 72-mm DIN
Note: 1. Available only on yearly models.
Features
Easier and More Convenient to Use
■ Simple Setting
■ Convenient Functions
Time Counter/Total Counter Functions (See note.)
This function makes it possible to monitor the total time that a load
has been applied, or the total number of operating cycles. It allows
the Time Switch to be used for managing maintenance.
output for holidays and non-operating days.
standards.
Yearly models also offer automatic switching to DST.
speedier setting.
accurate time over a wide temperature range. (See note 1.)
indicator. (See note 2.)
(See note 3.)
size added to the series.
Digital Time Switch
H5S
Independent Day Keys make setting easy.
2. Available only on 2-circuit models.
3. Available only on weekly models.
With alarm indicator
Shows total lamp ON time
Up/down set value changing
for speedy setting.
Temporary holidays
(non-operating days)
are also easy to set.
Weekly models: Specify the day.
Yearly models: Specify the date.
Time Adjustment Function (See note.)
The time can be set to 00 min 00 s by using an external input. The
times on multiple Time Switches can also be easily synchronized.
Note: Equipped on 2-circuit models.
Master
Slave
Synchronized!
Slave
CSM_H5S_DS_E_3_1
1

Related parts for Y92F-90

Y92F-90 Summary of contents

Page 1

Digital Time Switch H5S Easier, More Convenient Time Switches, with New 4-circuit Output and Yearly Models in Addition to 2-circuit Weekly Models • Independent Day Keys provide easier operation. • Temporary holiday setting function makes it easy to turn OFF ...

Page 2

More Applications on New Series Models Yearly Models Automatic Program Switching by Seasons The yearly operation can be set to automatically change the weekly program depending on the season. (See note.) Mar Apr May Jun Jul Aug Sep Oct Nov ...

Page 3

... VAC track mounting 24 VDC Flush mounting 100 to 240 VAC 24 VDC Surface mounting/ 100 to 240 VAC track mounting 24 VDC Model Y92A-72C Y92F-90 Y92A-72H Yearly 2-circuit Models (H5S-W@2) (H5S-Y@2) Approx. 3 264 VAC 60 Hz Approx. 0 28.8 VDC H5S Models H5S-WB2 H5S-WB2D H5S-WFB2 ...

Page 4

Characteristics Item Weekly 2-circuit Models (H5S-W@2) ±0.01%±0.05 s max. (See note 1.) Accuracy of operating The ±0.01% value applies to the set time interval. time Setting error Influence of voltage Influence of temperature ±15 s per month (at 25°C) ...

Page 5

Operation Item Weekly 2-circuit Models Operation method Digital quartz Operation period 1 week (7 days) Display • Day, hrs (switchable between 24-hr indication and a.m./p.m. 12-hr indication), minutes, seconds (0.00 to 23:59, 0.00 to 11:59 a.m., 0.00 to 11:59 ...

Page 6

Item Weekly 2-circuit Models (H5S-W@2) Checking the Consecutively displays the times when the output is set to turn ON and OFF for one day in the sequence in which the Time settings Switch is to operate. For details, refer to ...

Page 7

Connections ■ Terminal Arrangement H5S-@A@/-@B@ Flush Mounting Models Two-circuit Models Output 2 Input (Rear View − ∼ ∼ Power Output 1 source H5S-@FA@/-@FB@ Surface Mounting Models Two-circuit Models Input Output 2 ...

Page 8

Nomenclature Front Panel (with Cover Open) Weekly Two-circuit Models 13. Day Keys 12. Output ON/OFF Switches 11. Output Setting Switches 10. Time Adjustment 9. Test Key Key 8. Copy/Cycle Key Yearly Two-circuit Models 13. Day Keys 12. Output ON/OFF Switches ...

Page 9

Display Weekly Two-circuit Models 3. Summer time indicator 1. Power indicator 2. AM/PM indicator 18. Output circuit number indicator 17. Day indicator 16. Time adjustment mode indicator 11. Bank indicator 12. From/To indicator 14. Copy indicator Yearly Two-circuit Models 3. ...

Page 10

... M4 tapping screws (guideline) Panel thickness t 0.8 to 1.2 1 Hole diameter 3.6 3.7 (DIN track mounted) Y92F-90 DIN Track Mounting Base (Order separately) DIN Track Mounting panel 71.1 *1 79.8 *2 Note: 1. Using a PFP-50N or PFP-100N Mounting Track. 2. Using a PFP-100N2 Mounting Track. ...

Page 11

... The numbers in parentheses ( ) are dimensions for the PFP-50N End Plate PFP-M M4 × 8 pan-head screw 50 11 spring washer DIN Track Mounting Base Y92F-90 Note: The DIN Track Mounting Base can be used only with the surface mounting models (H5S-@FA@/-@FB@). PFP-100N2 7.3 ±0.15 4.5 35 ±0.3 27 ±0.15 ...

Page 12

Safety Precautions !CAUTION Minor injury by electric shock may occasionally occur. Do not touch any of the terminals while power is being supplied. Be sure to mount the terminal cover after wiring. When using a surface-mounting model in an exposed ...

Page 13

EN/IEC Standards • The insulation system between the power supply circuit and input- output terminals provides basic insulation. Therefore connect the output terminals only to circuits without exposed conductive parts connection to a Safety Extra Low Voltage ...

Page 14

Time Adjustment (Weekly Models) Weekly, 2 Circuits Example: Set the current time to Saturday 17:28. 1. Set the Mode P1 Switch to RUN. Shaded portion indicates P2 blinking of the indicator. RUN 2. Press TIME ADJ for ...

Page 15

Ordinary Timer Operation Weekly, 2 Circuits Yearly, 2 Circuits Yearly, 4 Circuits Example 8:30 and OFF at 17:15 on Monday through Friday. SUN MON TUE WED THU 8:30 17:15 8:30 17:15 8:30 17:15 8:30 17:15 8:30 17:15 1. ...

Page 16

Multiple-day Operation 2 Weekly, 2 Circuits Yearly, 2 Circuits Yearly, 4 Circuits Example 22:00 from Monday through Friday and OFF at 8:00 each following morning. SUN MON TUE WED THU ...

Page 17

Cyclic Operation Weekly, 2 Circuits Yearly, 2 Circuits Yearly, 4 Circuits Example: ON for 5 minutes and OFF for 1 hour 55 minutes repeatedly from 8:00 to 19:00 on Sunday. SUN Start 5 min min 8:00 1. ...

Page 18

Clearing the Settings Weekly, 2 Circuits Yearly, 2 Circuits Yearly, 4 Circuits Partial clearing 1. Set the Mode Switch and Shaded portion indicates select the setting to be cleared. blinking of the indicator. 2. Press CLEAR ...

Page 19

Yearly Timer Operation Yearly, 2 Circuits Yearly, 4 Circuits Example 18:00 and OFF at 22:15 on March 25 every year. Set the program in the following order. Day March 25, 2006 (Start date) period March 25, 2006 (End ...

Page 20

Convenient Functions Setting Temporary Holidays (Weekly) Weekly, 2 Circuits Temporary holidays (non-operating days) can be easily set. Because the setting is automatically cleared after the set holiday has passed, temporary holidays are easily set without changing other settings, including those ...

Page 21

Program Check Function Weekly, 2 Circuits Yearly, 2 Circuits Yearly, 4 Circuits The days and times when output is set to turn ON and OFF over the course of one week can be displayed in the sequence in which the ...

Page 22

Switching between 12-hour and 24- hour display Weekly, 2 Circuits Yearly, 2 Circuits Yearly, 4 Circuits h Each time is pressed for more in RUN mode, the current time switches between 12-hour (AM/PM) and 24-hour display. SUN ...

Page 23

Using Advanced Functions About Advanced Functions Set the advanced functions as required to perform more advanced operation. Outlines of the advanced functions are provided on the following pages. Refer to the Instruction Manual enclosed with the H5S for details. Initial ...

Page 24

Time Adjustment Input Function (F2) Weekly, 2 Circuits Yearly, 2 Circuits The time can be set to 00 min the same time as external input is applied. (The hours is rounded up for 30 minutes or higher ...

Page 25

Period of Season (F9) Shaded portion indicates blinking of the indicator. 1. Press season. 2. Press WRITE The display then changes to the start period of season input screen. Press designate the starting ...

Page 26

Summer Time Schedule Selection (F7) Yearly, 2 Circuits Yearly, 4 Circuits The time and date when the Time Switch automatically switches to and from summer time can be selected with reference to the following regions. Parameters Regions Summer time start ...

Page 27

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords