Y92F-90 Omron, Y92F-90 Datasheet - Page 5

no-image

Y92F-90

Manufacturer Part Number
Y92F-90
Description
H5S TRACK MNT ADAPTER
Manufacturer
Omron
Type
Track Mounting Basesr
Datasheet

Specifications of Y92F-90

Rohs Compliant
YES
Accessory Type
Adapter - Panel Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
H5S-FB
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Y92F90
■ Operation
Note: 1. Depending the operation, the following steps can be used for weekly programs.
■ Operation Functions
Operation method
Operation period
Display
Min. setting unit
Number of
steps that
can be set
Weekly timer
operation
Weekly pulse-
output
operation
Weekly cyclic
operation
Yearly timer
operation
Yearly pulse-
output
operation
Temporary
holiday setting
Day override
operation
Program check Consecutively displays the days and times when the output is set to turn ON and OFF over the course of one week in the
2. When the season switching setting is not being used.
3. When the season switching setting is being used.
Item
Item
Weekly program
(See note 1.)
Yearly program
Number of
settable yearly
temporary
holiday settings
Timer operation: 2 steps
Pulse-output operation: 1 step
Cyclic operation: 4 steps
---
---
Sets temporary holidays (non-operating days) without having to revise the existing program.
For details, refer to Setting Temporary Holidays (Weekly) and Setting Temporary Holidays (Yearly) on page 20.
Executes the operation for one day
temporarily on another day in the 7-day
period starting from the current day.
For details, refer to Day Override
Operation on page 21.
sequence in which the Time Switch is to operate.
For details, refer to Program Check Function on page 21.
Timer operation
Pulse output operation
Cyclic operation
Weekly 2-circuit Models (H5S-W@2)
Start
ON
ON
ON
Pulse width
Digital quartz
1 week (7 days)
• Day, hrs (switchable between 24-hr indication and a.m./p.m. 12-hr indication), minutes, seconds
• Digital indication by LCD (character height: 10 mm)
• Digital display of operation schedule during operation
• Timing chart display of operation schedule during operation
1 min
40 steps/circuit
---
---
OFF
(0.00 to 23:59, 0.00 to 11:59 a.m., 0.00 to 11:59 p.m.)
Stop
OFF
Weekly 2-circuit Models
(H5S-W@2)
Controls the output according to the set time of ON and OFF.
• Min. setting unit: 1 min
• Multiple-day operation also possible.
Output turns ON for a fixed period (pulse width) at the set ON time.
• Pulse width: 1 to 59 s (in 1-s increments), or 1 to 60 min (in 1-min increments)
• The pulse width can be set for each step.
Repeatedly turns ON and OFF during the period from the cyclic start time to the stop time.
Independent ON- and OFF-time settings are possible.
• Min. setting unit: 1 min
Adds a yearly timer operation to the weekly timer program.
For details, refer to About Yearly Programs on page 18.
Adds a yearly pulse-output operation to the weekly pulse-output program.
For details, refer to About Yearly Programs on page 18.
---
Yearly 2-circuit Models (H5S-Y@2)
1 year (with integrated calendar to 2099)
48 steps/circuit (See note 2.)
24 steps/circuit (per season) (See
note 3.)
4 yearly programs/circuit
16
Yearly 2-circuit Models
(H5S-Y@2)
Yearly 4-circuit Models (H5S-Y@4)
48 steps/circuit (See note 2.)
12 steps/circuit (per season) (See
note 3.)
Yearly 4-circuit Models
(H5S-Y@4)
H5S
5