MM-PENTRA-24-HG1F IDEC, MM-PENTRA-24-HG1F Datasheet

PLC Solution Package

MM-PENTRA-24-HG1F

Manufacturer Part Number
MM-PENTRA-24-HG1F
Description
PLC Solution Package
Manufacturer
IDEC
Datasheet

Specifications of MM-PENTRA-24-HG1F

Kit Contents
4.6" HG1F Monochrome STN Touchscreen Operator Interface, 24 I/O All-in-one CPU, 30W Power Supply, WindO/I-NV2 Software, XWIE E-stop & Name Plate, PC Cable
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table of Contents
Programmable Logic
Controllers
Automation & Sensing - Pg. 1
• New and updated product information
• Downloadable software demos & upgrades
• Part confi guration tool & cross reference
• Online stock check & ordering
• IDEC fi eld sales & distributor search
• Online literature request
For more information on this product family, visit our website.
www.idec.com/plc
Additional resources include:
Safety - Pg. 315
• Downloadable manuals & CAD drawings
• Manufacturer’s suggested retail price list
• Product training schedule & locations
• Advertising & trade show schedules
• Press releases & FAQs
Switching & Controls - Pg. 439
Selection Guide ...............................................
MicroSmart Family ..........................................
OpenNet Controller .......................................
IDEC SmartRelay ...........................................
MicroSmart Pentra CPU Part Numbers ..............7
MicroSmart CPU Part Numbers .........................8
Expansion Modules ..........................................10
Programming Software - WindLDR .................23
Specifi cations & Dimensions ...........................24
Selection Guide ................................................58
Programming Software - WindLGC .................60
Specifi cations & Dimensions ...........................61
Automation & Sensing
Index - Pg. 911
45
56
2
3

Related parts for MM-PENTRA-24-HG1F

MM-PENTRA-24-HG1F Summary of contents

Page 1

... Programming Software - WindLDR .................23 Specifi cations & Dimensions ...........................24 OpenNet Controller ....................................... IDEC SmartRelay ........................................... Selection Guide ................................................58 Programming Software - WindLGC .................60 Specifi cations & Dimensions ...........................61 Additional resources include: • Downloadable manuals & CAD drawings • Manufacturer’s suggested retail price list • Product training schedule & locations • ...

Page 2

... High-Speed I/O Freq. 100KHz Approvals 2 Selection Guide Programmable Logic Controllers MicroSmart Family OpenNet Controller (ONC) MicroSmart 8 24V DC, 100-240V AC 264 56 31.2K bytes 2 - Yes - - - 20KHz www.idec.com Programmable Logic Controllers SmartRelay 45 56 12-24V DC, 24V AC/DC, 24V DC 100-240V AC/DC 480 32K bytes 2K bytes Yes - Yes Yes ...

Page 3

... For added convenience, the same expansion I/O modules and accessories can be used on both the MicroSmart and MicroSmart Pentra controllers. In fact, both controllers share the same architecture, instruction set and programming software. The use of a single software platform for all IDEC PLCs means you won‘ ...

Page 4

... Extend the life of your PLC! Upgrade your fi rmware on-site as new functions and versions become available. Built-in Modbus RTU/ASCII master & slave, and Modbus TCP (1:1) de-facto protocol Modbus messaging protocol is a de-facto protocol in industrial networking. Communication with other devices on a Modbus network can be easily achieved with built-in Macros instructions. ...

Page 5

... Programmable Logic Controllers Maximum 7 Communication Ports MicroSmart Pentra models can accomodate total of seven communica- tion ports. Now you can connect your HMI, PC, barcode reader, RFID equipment, printer and more. 56 PID Loops PID is the standard solution to many industrial process controls because of its accuracy and stability. With PID loops and advanced auto-tuning features, your systems can be tuned to optimum values for the desired control response ...

Page 6

... Potentiometers (x2) All-in-one CPU Optional HMI module for monitoring Built-in Optional HMI base module Potentiometer or RS232C/RS485 Comm. Modules www.idec.com Programmable Logic Controllers FC5A-C24R2C Optional Real Time Optional EEPROM Clock cartridge memory cartridge Built-in 0-10V analog input Built-in RS232C port Slim CPU Optional Real Time ...

Page 7

... Programmable Logic Controllers All-in-One Appearance Part Number Power FC5A-C10R2C 24V DC FC5A-C10R2 100-240V AC FC5A-C16R2C 24V DC FC5A-C16R2 100-240V AC FC5A-C24R2C 24V DC FC5A-C24R2 100-240V AC Slim Appearance Part Number Power FC5A-D16RK1 FC5A-D16RS1 24V DC FC5A-D32K3* FC5A-D32S3* *See page 20 for MIL Connector Cables and Breakout Modules. MicroSmart Pentra CPU Part Numbers ...

Page 8

... Built-in 2 High speed outputs (Slim model only) • Confi gure up to 264 I/O Points • Data link MicroSmart and Pentra CPUs • Using RS485 communication module/port, you can create a network CPUs. • Worldwide Approvals -cULus listed, CE marked -Class 1 Div. 2 for hazardous locations ...

Page 9

... Programmable Logic Controllers Slim Appearance Part Number Power FC4A-D20RK1 FC4A-D20RS1 FC4A-D20K3 FC4A-D20S3 FC4A-D40K3 FC4A-D40S3 MicroSmart CPU Part Numbers I/O Points Input 20 (12 in/8 out) 24V DC 24V DC (Sink/Source) 40 (24 in/16 out) USA: 800-262-IDEC Canada: 888-317-IDEC MicroSmart Series Output Expandability 6 Relays, 2 Transistor Sink ...

Page 10

... Up to 512 I/O can be confi gured in the Pentra and 264 I/O in the MicroSmart system Input Modules Appearance Part Number FC4A-N08A11 FC4A-N08B1 FC4A-N16B1 FC4A-N16B3 FC4A-N32B3 10 Digital I/O Expansion Modules Input Input Points Terminal 100-120V AC 8 Removable Screw Terminals 24V DC 16 MIL Connector (ribbon cable) 32 www.idec.com Programmable Logic Controllers ...

Page 11

... Programmable Logic Controllers Output Modules Appearance Part Number FC4A-R081 FC4A-R161 FC4A-T08K1 FC4A-T16K3 FC4A-T32K3 Digital I/O Expansion Modules Output Output Points 8 Relay Transistor Sink 32 USA: 800-262-IDEC Canada: 888-317-IDEC MicroSmart Series Terminal Removable Screw Terminals MIL Connector (ribbon cable) 11 ...

Page 12

... Digital I/O Expansion Modules Output Output Points 8 Transistor Source 16 32 Input Output I/O Points 24V DC (Sink/Source) Relay www.idec.com Programmable Logic Controllers Terminal Removable Screw Terminals MIL Connector (ribbon cable) Terminal 8 (4 in/4 out) Removable Screw Terminals 24 (16 in/ 8 out) Wire Spring Clamp ...

Page 13

... Programmable Logic Controllers Features: • 8 modules • 0-10V, 4-20mA, RTD, Thermocouple, Thermistor inputs, 0-10V DC or -10V DC to 10V DC output • 16-bit resolution • Fast conversion time • Maximum of 56 I/O can be confi gured in the MicroSmart Pentra system • Easy to confi gure using a Macro instruction in WindLDR ...

Page 14

... I/O Points FC4A-J8AT1 8 (8 inputs) FC4A-K2C1 2 (2 outputs) FC4A-K1A1 1 (1 output) 14 Analog I/O Expansion Modules Input Output Thermistor (NTC/PTC) – – -10 to 10V DC, 4-20mA – 0-10V DC, 4-20mA www.idec.com Programmable Logic Controllers Resolution Terminal 12-bit (0-4000) Removable Screw 16-bit (0-50000) Terminals 12-bit (0-4095) ...

Page 15

... Programmable Logic Controllers Features: • Easy to confi gure • Comes with interface cable and Quick Start Guide Part Numbers Appearance Part Number FC4A-ENET FC9Y-QS100-0 Quick Start Guide Web Server Module for MicroSmart PLC Web Server Functions • Machine status can be monitored and controlled from any PC using stan- dard internet browsers, such as Internet Explorer. • ...

Page 16

... MicroSmart AS-Interface Master Module IDEC offers a plug-in AS-Interface master module (as well as other AS-Interface devices, please see AS-Interface Communication section) that is easy to confi g- ure; it can also connect slaves. With this technology, you’ll reduce the amount of engineering needed, simplify wiring and enhance your operations; ...

Page 17

... RFID equipment, printer and more. Just imagine the possibilities. RS232 Communication Module for MicroSmart Using the MicroSmart Pentra slim CPU,you can confi gure up to seven communi- Pentra cation ports. Using the All-in-one MicroSmart Pentra you can communicate with up to fi ve serial devices. ...

Page 18

... Description FC4A-PC1 FC4A-PC2 FC4A-PC3 18 Optional Modules Description Usage For mounting HMI module and communication ports with slim model CPU module HMI Base Module (HMI module is not included) HMI Module For displaying and changing operands EEPROM memory 32KB EEPROM memory cartridge cartridge ...

Page 19

... Programmable Logic Controllers Communication Module — for Slim CPU Appearance Part Number Description FC4A-HPC1 RS232C FC4A-HPC2 RS485 FC4A-HPC3 RS485 Expansion Power Supply System Confi guration Slim CPU Module FC5A-EXM1M and FC5A-EXM1S (Expansion Interface Master & Salve Modules) Slim CPU Module ...

Page 20

... FC9Z-H300A20 5ft. (1.5m) FC9Z-H100C20A 26-terminal breakout module 26-terminal touch-down terminal breakout module 20-terminal breakout module 20-terminal touch-down terminal breakout module www.idec.com Programmable Logic Controllers Part Expanded Length Number Description Modem cable. Used FC2A-KM1C to connect a modem 9.84 Ft. (3m) to the MicroSmart RS232C port. ...

Page 21

... I/O CPU 9-pt input simulator switch for 16 I/O CPU 6-pt input simulator switch for 10 I/O CPU End clips DIN Rail (1m/3.28’ long, 10.5mm height) DIN Rail (1m/3.28’ long, 7.5mm height) 2.5mm fl athead IDEC screwdriver MicroSmart user manual ...

Page 22

... MM-SMART-40-HG2F-M MM-SMART-16-HG2F-C MM-SMART-20-HG2F-C MM-SMART-24-HG2F-C MM-SMART-40-HG2F-C MM-SMART-20-HG3F MM-SMART-24-HG3F MM-SMART-20-HG4F MM-SMART-24-HG4F MM-PENTRA-16-HG1F MM-PENTRA-24-HG1F MM-PENTRA-16-HG2F-C MM-PENTRA-24-HG2F-C MM-PENTRA-16-HG3F MM-PENTRA-24-HG3F MM-PENTRA-16-HG4F MM-PENTRA-24-HG4F 1. *HG1F: Light Gray Bezel, RS232 Comm., HG2F/3F/4F: Light Gray Bezel. 2. All packages come with WindLDR & WindO/I-NV2 software, programming and interface cables. 22 Starter Kits and Solution Packages ...

Page 23

... Simple-to-use Editors Use the tag editor to access and edit coil data. Edit comments and rung com- ments. Simulation mode tests your program in WindLDR to guarantee that it works the way you expected, before downloading it to your PLC. ...

Page 24

... Free from corrosive gases IP20 (IEC60529) UL1007, AWG16 When mounted on a DIN rail or panel surface amplitude 3.5 mm 150 Hz acceleration 9.8 m/s 2 hours per axis on each of three mutually perpendicular axes (IEC61131-2) 2 147 m/s (15G), 11ms duration, 3 shocks per axis, on three mutually perpendicular axes (IEC61131) ...

Page 25

... Possible Function Area Settings, then run-time program download cannot be used. 5. Maintenance communication, user communication, Modem communica- tion, data link, Modbus master/slave communication (FC5A only). Note: The maximum number of relay outputs that can be turned on simulat- neously is 54 including those on the CPU module. ...

Page 26

... Not including expansion I/O service time, clock function processing time, data link processing time, and interrupt processing time. 3. Maintenance communication, user communication, Modem communication, datalink, Modbus master/slave communication (FC5A only). Note: The maximum number of relay outputs that can be turned on simultaneously is 33 including those on the CPU module. ...

Page 27

... Programmable Logic Controllers Communication Port (RS232C Port 1) Model Standards Maximum Baud Rate Maintenance Communication User Communication Modem Communication Data Link Cable Isolation between Internal Circuit and Communication Port Input Specifi cations – Part Number FC4A-D20K3 FC4A-D20S3 12 Input Points (12/1 common) Input Voltage Input Voltage Range FC5A I0, I1, I3, I4, I6, I7: 4 ...

Page 28

... COM3 — — form A 2A per point 8A per common line 0.1mA/0.1V DC (reference value) 30 mΩ maximum 100,000 operations minimum (rated load 1,800 operations/hour) 20,000,000 operations minimum (no load 18,000 operations/hour) 240V AC/2A (resistive load, inductive load cos ø = 0.4) 30V DC/2A (resistive load, inductive load L/R =7ms) ...

Page 29

... Programmable Logic Controllers Input Usage Limits FC5A-D16RK1/D16RS1 FC5A-D32K3/D32S3 FC4A-D40K3/D40S3 Input Voltage (V DC) Ambient Temperature Input Voltage (V DC) 40ºC 26.4 26.4 Ambient Temperature 24.0 24.0 55º 100 0 I/O Simultaneous ON Ratio (%) I/O Simultaneous ON Ratio (%) All-in-One CPU FC5A-C10R2 FC5A-C16R2 FC5A-C10R2C FC5A-C16R2C FC4A-C10R2 FC4A-C16R2 FC4A-C10R2C ...

Page 30

... Backup Duration mm 2 Battery 85Ω/km maximum 20Ω/km maximum Charging Time Replaceability www.idec.com Programmable Logic Controllers FC4A-PH1 5V DC (supplied from the CPU module) 20g FC4A-PM32 FC4A-PM64 EEPROM CPU Module WindLDR One user program can be stored on one memory cartridge FC4A-PT1 ± ...

Page 31

... Hz) 9V minimum 20V maximum — — 25ms 30ms Between input terminals in the same common: Not isolated Between input terminals in different commons: Isolated Between input terminals and internal circuits: Photocoupler isolated Not needed Static If any input exceeding the rated value is applied, permanent damage may be caused. — ...

Page 32

... DC) Between input terminals: Not isolated Internal circuit: Photocoupler isolated Not needed Static Both sinking and sourcing input signals can be connected. If any input exceeding the rated value is applied, permanent damage may be caused compliance with electromagnetic immunity www.idec.com Programmable Logic Controllers ...

Page 33

... FC4A-M08BR1 FC4A-M24BR2 4 (4/1 common) 8 (4/1 common) 1NO (form A) 2A per point 7A per common 0.1mA/0.1V DC (reference value) 30 mΩ maximum 100,000 operations minimum (rated load 1,800 operations/hour) 20,000,000 operations minimum (no load 18,000 operations/hour) 240V AC/2A (resistive load, inductive load cos ø = 0.4) ...

Page 34

... DC 20.4 to 28.8V DC MC1.5/11-G-3.81BK (Phoenix Contact) 100 times minimum 30mA 30mA 30mA 0mA 50mA (24V DC) 40mA (24V DC) 25mA (24V DC) 140g 140g 125g www.idec.com Programmable Logic Controllers Input Circuit + 15MΩ 1 kΩ NC (A) 1 kΩ + (B’) Input 10Ω 1 kΩ – (B) ...

Page 35

... Maximum Temporary Deviation ±3% maximum when a 500V clamp voltage is applied to the power and I/O wiring during Electrical Noise Tests Input Filter No Noise Resistance Twisted pair shielded cable is recommended for Cable improved noise immunity Crosstalk Dielectric Strength Type of Protection Effect of Improper Input Connection ...

Page 36

... Data Type in Application Program — Monotonicity Input Data Out of Range Maximum Temporary Deviation during Electrical Noise Tests Input Filter Twisted pair shielded cable is recom- Cable mended for improved noise immunity Crosstalk 2 LSB maximum Isolation 36 FC4A-J4CN1 Resistance Current Input Thermocouple Thermometer Pt100, Pt1000 3-wire type (–100 Type 1300º ...

Page 37

... Default 4095 (standard) Optional: –32768 to 32767 (optional range designation) Undetectable ±3% maximum when a 500V clamp voltage is applied to the power and I/O wiring Twisted pair shielded cable is recommended for improved noise immunity None 500V Photocoupler-isolated Using software programming USA: 800-262-IDEC ...

Page 38

... Beyond the expansion interface module Connectable I/O modules: 8 digital I/O modules maximum (AC input modules are not applicable) 3.6ms Asynchronous communication (I/O refresh of I/O modules on both sides of the expansion interface module is asynchronous.) Only communication interface part is isolated 1m (FC5A-KX1C) MKDSN1.5/3-5.08-BK — (Phoenix Contact) — ...

Page 39

... Programmable Logic Controllers Basic Instructions Symbol Function AND Series connection of NO contact AND LOD Series connection of circuit blocks ANDN Series connection of NC contact BPP Restores the result of bit logical operation which was saved temporarily BPS Saves the result of bit logical operation temporarily ...

Page 40

... Programmable Logic Controllers All-in-One FC5A FC5A -C16R2, C16R2C -C24R2, C24R2C FC4A FC4A -C16R2, -C16R2C -C24R2, -C24R2C × × × × × × × × ...

Page 41

... Programmable Logic Controllers Symbol Function RXD2 Receive 2 LABEL Label LJMP Label Jump LCAL Label Call LRET Label Return IOREF I/O Refresh HSCRF High-speed Counter Refresh FRQRF Frequency Measurement Refresh DI Disable Interrupt EI Enable Interrupt XYFS XY Format Set CVXTY Convert CVYTX Convert AVRG ...

Page 42

... FC4A-K2C1, 14.6 70.0 3.8 23.5 FC4A-N16B1, FC4A-R161 3.8 23.5 14.6 70.0 FC5A-EXM2, FC4A-M24BR2 1.0 70.0 3.8 39.1 42 Programmable Logic Controllers Dimensions (mm) FC5A-D32K3, FC5A-D32S3 FC4A-D40K3, FC4A-D40S3 47.5 11.3 70.0 FC5A-C24R2, FC5A-C24R2C FC4A-C24R2, FC4A-C24R2C 95.0 70.0 FC4A-EXM1M FC4A-N16B3, FC4A-T16K3, FC4A-T16S3 11.3 70.0 3.8 17 ...

Page 43

... FC5A-D16RK1 47.5 FC5A-D16RS1 24.1 FC5A-D32K3 FC5A-D32S3 FC4A-D20RK1 FC4A-D20RS1 FC4A-D40K3 FC4A-D40S3 3.0 Examples Mounting hole layout for FC5A-C24R2 or FC4A-C24R2 and four 23.5mm-wide I/O modules 12.3 23.5 23.5 23.5 3.0 3.0 3.0 3.0 83.0 15.3 23.5 23.5 23.5 Mounting Hole Layout (mm) FC4A-N08A11, FC4A-R081 ...

Page 44

... Specifi cations Connection Method Major Functions 2 (1G) Optional Connectable Devices Programmable Controllers IDEC FC5A MicroSmart IDEC FC4A MicroSmart IDEC FC3A OpenNet Controller Web Server Cable (FC4A-KC3C, Cable Length: 100 mm) Cable Dimensions To MicroSmart Cable Connection Diagram Connector for MicroSmart Pin No. Port 1 Port ...

Related keywords