166736-006 VEEDER ROOT, 166736-006 Datasheet - Page 138

Totalizer Display Panel

166736-006

Manufacturer Part Number
166736-006
Description
Totalizer Display Panel
Manufacturer
VEEDER ROOT
Datasheet

Specifications of 166736-006

No. Of Digits / Alpha
6
Digit Height
8.8mm
Mounting Type
Base
Lead Free Status / RoHS Status
na
R
O
N
E
L
E
C
T
C
I
5
M
R
S
T
E
M
I
T
E
R
S
I
OPERATION
The timing base for each of the two timing states (ON time and OFF time)
is generated by an internal oscillator set by a precision capacitor and a dial
adjustable potentiometer. This allows accurate control over the long time
ranges available with the DA100 series.
The DA100 alternately times its OFF and ON periods as long as power is
applied to the control input terminal. The output contacts change state at
the completion of each timing period. The DA100 resets when power is
removed from the control input.
SPECIFICATIONS
Time Ranges:
5.44
The DA100 is a solid state ON/OFF repeat cycle timer housed in a 1/8
DIN, molded NORYL
for the timing function. Sixteen time ranges are available in any
combination of ON and OFF periods. Two knobs reference to a
calibrated scale provide the individual time settings. Two front mounted
pilot lights indicate timing status.
All connections made through standard square base relay socket
Available accessories for conversion into panel mount including a
version with plug-in capability
Standard unit times its OFF period first and provides an isolated
double pole - double throw relay contact output
Available options include ON-Time First timing and One-Cycle
timing (previously required two time delay relays)
Sym.
EAGLE SIGNAL
10
11
12
13
14
15
16
17
Electronic Timers
VEEDER-ROOT • EAGLE SIGNAL • DYNAPAR
120 Sec.
Range
3.5 Sec.
15 Sec.
30 Sec.
60 Sec.
7 Sec.
4 Min.
8 Min.
Dial
®
case. The timer uses CMOS integrated circuits
Minimum
Setting
.37 Sec.
.75 Sec.
1.5 Sec.
12 Sec.
24 Sec.
48 Sec.
3 Sec.
6 Sec.
Sym.
18
19
20
21
22
23
24
25
brand
120 Min.
Range
15 Min.
30 Min.
60 Min.
15 Hr.
30 Hr.
Dial
4 Hr.
8 Hr.
Minimum
12.8 Min.
25.6 Min.
51.2 Min.
Setting
1.6 Min.
3.2 Min.
6.4 Min.
1.7 Hr.
3.4 Hr.
DA100 MINIFLEX
Operating Voltage/Frequency:
Setting Accuracy: Within 10% of maximum range
Repeatability (Constant Voltage & Temperature):
Repeatability (Voltage & Temperature Variation):
Reset Time: 65 ms
Cycle Progress: Pilot lights during ON time and OFF time
Power on Response: 30 ms max. after line voltage applied to pins A and B
Operating Temperature: 0° to 60°C (+32° to +140°F)
Output Rating:
Power Interruption:
Transient Voltage Immunity: Unaffected by 50 microseconds, 600 V peak
Vibration: Unit function is unaffected by 2.5
Approvals: UL Recognition E96337
120 VAC (+10 -15%), 50/60 Hz or 120 VDC (+10 -15%)
240 VAC (+10 -15%), 50/60 Hz or 240 VDC (+10 -15%)
24 VAC, 50/60 or 24 VDC
Variable Voltage:
Variable Temperature:
Variable Voltage and Temperature:
Relay: 10 amp steady state
Mechanical Life: over 20 million operations
Electrical Life: contingent upon load characteristics
Line voltage interruptions of 20 ms or less will not reset unit
transients superimposed on the line input
in both directions of three perpendicular mounting axes imposed from 10
to 100 Hz
CSA Certification L26861
FM Approved J10C8A4.AF
0.1% of setting or 25 ms, whichever is longer
Continuous repeat
cycle timing in a
compact 1/8 DIN
case... fast, easy
analog dial setpoint
adjustment
1% of setting
®
On/Off Repeat Cycle
2% of setting
3% of setting
®
RECOGNIZED
G
sinusoidal vibration magnitude
CERTIFIED
®
A P P R O V E D