LD4A05P0 Red Lion Controls, LD4A05P0 Datasheet
LD4A05P0
Specifications of LD4A05P0
Related parts for LD4A05P0
LD4A05P0 Summary of contents
Page 1
... Use the 10V range Use the 10V range OLOL ”. ULUL ”. ..... ”/“- PART X (Length) NUMBER LD2A05P0 16 (406.4) 4 (101.6) Y LD4A05P0 26 (660.4) 7.875 (200) 2.25 (57.15) Bulletin No. LDA-C Drawing No. LP0673 Released 09/09 TEMP. COEFFICIENT 10 μV 70 ppm /°C 70 ppm /° ppm /°C 70 ppm /° ...
Page 2
A/D CONVERTER: 16 bit resolution A/D Conversion Rate: 6 readings/sec. 6. DISPLAY RESPONSE TIME: 500 msec min. 7. USER INPUT: Software selectable pull-up (8.6 K) or pull-down resistor (3.9 K) that determines active high or active low input logic. ...
Page 3
W IRING THE EMC INSTALLATION GUIDELINES Although this meter is designed with a high degree of immunity to Electro- Magnetic Interference (EMI), proper installation and wiring methods must be followed to ensure compatibility in each application. The type of ...
Page 4
USER INPUT WIRING The User Input is located: LD2 - left side, LD4 - right side Terminal 5: User Input Terminal 6: User Comm 3.3 SETPOINT (OUTPUT) WIRING The setpoint relays use a six position terminal block (TBB) located ...
Page 5
SERIAL WIRING The serial connections are made via terminal block TBD located inside the unit on the left side for the LD2 and on the right side for the LD4. 1 TXD 2 RXD 3 COMM TBD 4 A ...
Page 6
P ROGRAMMING THE DISPLAY MODE PAR NO Signal Input Parameters Pro RST 1-INP PROGRAMMING MODE ENTRY (PAR BUTTON recommended all programming changes be made off line, or before installation. The meter normally operates in the Display Mode. ...
Page 7
Zero Display to show how far the display is offset. A value of zero removes the effects of offset. The decimal point follows the FILTER SETTING FILtr 0 the displayed value ...
Page 8
MODULE 2-SEC PAR HI-En HI-t Max Display Max Capture Enable Delay Time MAX DISPLAY ENABLE HI-En NO YES NO Enables the Maximum Display Capture capability. MAX CAPTURE DELAY TIME HI 999. ...
Page 9
MODULE 3-dSP PAR dSP-t SEL Display Front Panel Update Time Display Select Enable DISPLAY UPDATE TIME dSP 1 This parameter sets the display update time in seconds. FRONT PANEL DISPLAY ...
Page 10
MODULE 4-SPt PAR SPSEL Act-n Enb-n Setpoint Setpoint Setpoint Select Enable Action SETPOINT SELECT SPSEL NO SP-1 NO Enter the setpoint (output programmed. The parameters will reflect the chosen setpoint number. After ...
Page 11
Display Value is lower than setpoint value.) L-dLY = Latch with delay reset action; This ...
Page 12
METER ADDRESS Addr 00 Enter the serial node address. With a single unit, an address is not needed and a value of zero can be used (RS232 applications). Otherwise, with multiple bussed units, a unique ...
Page 13
Receiving Data From The Meter Data is transmitted from the meter in response to either a transmit command (T), a block print request command ( User Input print request. The response from the meter is either a full ...
Page 14
Communication Format Data is transferred from the meter through a serial communication channel. In serial communications, the voltage is switched between a high and low level at a predetermined rate (baud rate) using ASCII encoding. The receiving device reads the ...
Page 15
LDA PROGRAMMING QUICK OVERVIEW 15 ...