T4811100 Red Lion Controls, T4811100 Datasheet - Page 3

no-image

T4811100

Manufacturer Part Number
T4811100
Description
TMP CNTL,01R,A1R,A2R
Manufacturer
Red Lion Controls
Type
Temperaturer
Datasheet

Specifications of T4811100

Rohs Compliant
NA
Brand/series
T48 Series
Contact Form
SPST
Current, Load
1 A @ 35 °C (Max.)
Dimensions
49.5mmW×49.5mmH×115.3mmD
Enclosure Rating
IP65
Input Type
RTD/Thermocouple
Ip Rating
IP65
Memory
EEPROM
Mounting Type
Panel
Number Of Outputs
1
Output Type
Relay
Power, Rating
8 VA
Primary Type
Controller
Special Features
EEPROM
Standards
cURus, CE
Temperature, Ambient
0 to +50 °C (Max.)
Termination
Screw
Voltage, Rating
120⁄240 VAC
Voltage, Supply
85 to 250 VAC
Panel Cutout
1.77" × 1.77" (1⁄16 DIN)
Power Requirements
85-250 VAC
Sealing
NEMA 4X/IP65
Operating Temperature
0°C to +50°C
Lead Free Status / Rohs Status
RoHS Compliant part
13. COOLING: Software selectable (overrides alarm 2)
14. MAIN AND SECOND LINEAR DC OUTPUT: (optional)
* Accuracies are expressed as ± percentages after 20 minutes warm-up. Output
** Outputs are independently jumper selectable for either 10 V or 20 mA. The
15. REMOTE SETPOINT INPUT: (optional)
16. HEATER CURRENT MONITOR INPUT: (optional)
17. SERIAL COMMUNICATIONS: (optional)
18. ENVIRONMENTAL CONDITIONS:
0 to 20 mA
4 to 20 mA
Reset Action: Programmable; automatic or latched
Standby Mode: Programmable; enable or disable
Hysteresis: Programmable
Probe Break Action: Upscale
Annunciator: LED backlight for “A1”, “A2”
Control: PID or ON/OFF
Output: Time Proportioning
Cycle time: Programmable
Proportional Gain Adjust: Programmable
Heat/Cool Deadband Overlap: Programmable
Main: Control or Re-transmission, programmable update rate from 0.1 sec to
Second: Re-transmission only, fixed update rate of 0.1 sec
OUTPUT **
accuracy is specified in two ways: Accuracy over an 18 to 28°C range at 10
to 75% RH environment; and accuracy over a 0 to 50°C range at 0 to 85%
RH (non-condensing) environment. Accuracy over the wide temperature
range reflects the temperature coeffecient of the internal circuitry.
output range may be field calibrated to yield approximately 10% overrange
and a small underrange (negative) signal.
Input type:
Input Resistance: 10 Ω
Overrange: -5% to 105%
Overload: 100 mA (continuous)
Scale Range: -999 to 9999 degrees or -99.9 to 999.9 degrees.
Resolution: 1 part in 10,000.
Accuracy:
Reading Rate: 10/sec.
Setpoint Filtering: Programmable Digital
Setpoint Ramping: Programmable, 0.1 to 999.9 degrees/minute.
Type: Single phase, full wave monitoring of load currents controlled by main
output (01).
Input: 100 mA AC output from current transformer (RLC #CT004001) or
any CT with 100 mA AC output.
Display Scale Range: 1.0 to 999.9 Amps or 0.0 to 100.0%
Input Resistance: 5
Accuracy:
Frequency: 50 to 400 Hz.
Alarm Mode: Dual acting; heater element fail detect and control device fail
detect.
Overrange: 105% Capacity
Overload: 200 mA (continuous).
Type: RS485 multipoint, balanced interface
Baud Rate: 300 to 9600
Data Format: 7O1, 7E1, 7N2, 8N1
Node Address: 0-99, max of 32 units per line
Transmit Delay: 2-100 msec or 100-200 msec
Data Encoding: ASCII
Isolation w.r.t Main Input Common: 500 Vrms for 1 min. (50 V working)
Note: RS485 and the Analog Output commons are not internally isolated
0 to 10 V
RANGE
250 sec
0/4 to 20 mA
At 25
Over 0 to 50
At 25
Over 0 to 50
within the controller. The terminating equipment of these outputs must not
share the same common (ie. earth ground).
Not isolated w.r.t. Remote Setpoint or Heater Current inputs, or Analog
Output common
Outside band acting
Heater break alarm
° °
° °
C:
C:
±
±
(0.1 % of full scale +
(0.5 % of full scale +
ACCURACY *
0.10% of FS
0.10% of FS
0.10% of FS
° °
(18 to 28°C)
° °
+ 1/2 LSD
+ 1/2 LSD
+ 1/2 LSD
C range:
C range:
±
±
(1.0% of full scale +
(0.2% of full scale +
ACCURACY *
0.30% of FS
0.30% of FS
0.30% of FS
+ 1/2 LSD
+ 1/2 LSD
+ 1/2 LSD
(0 to 50°C)
½
½
LSD)
LSD), (5 to 100% of Range)
½
500 ohm max.
500 ohm max.
10k ohm min.
½
LSD), (5 to 100% of Range)
COMPLIANCE RESOLUTION
LSD)
1/3500
1/3500
1/2800
3
19. ISOLATION BREAKDOWN RATINGS:
20. CERTIFICATIONS AND COMPLIANCES:
21. CONNECTION: Wire clamping screw terminals
22. CONSTRUCTION: Black plastic alloy case and collar style panel latch. Panel
23. WEIGHT: 0.38 lbs (0.17 kgs)
Operating Range: 0 to 50°C
Storage Range: -40 to 80°C
Span Drift (max.): 130 ppm/°C, main input
Zero Drift (max.): 1µV/°C, main input
Operating and Storage Humidity:
Altitude: Up to 2000 meters
AC line with respect to all Inputs and outputs: 250 V working (2300 V for
Main input with respect to Analog Outputs, Remote Setpoint Input,
All other inputs and outputs with respect to relay contacts: 2000 VAC
Not isolated between Analog Outputs, Remote Setpoint and Heater Current
SAFETY
ELECTROMAGNETIC COMPATIBILITY
Notes:
1. No loss of performance during EMI disturbance at 10 V/m.
2. Self-recoverable loss of performance during EMI disturbance at 10 Vrms:
Refer to the EMC Installation Guidelines section of the manual for additional
latch can be installed for vertical or horizontal instrument stacking. One piece
tinted plastic bezel. Bezel assembly with circuit boards can be removed from the
case to change the output board without removing the case from the panel or
disconnecting wiring. Unit meets NEMA 4X/IP65 requirements for indoor use,
when properly installed. Installation Category II, Pollution Degree 2.
Immunity to EN 50082-2
Electrostatic discharge
Electromagnetic RF fields
Fast transients (burst)
RF conducted interference
Power frequency magnetic fields
Simulation of cordless telephones
Emissions to EN 50081-2
RF interference
85% max. relative humidity (non-condensing) from 0°C to 50°C.
1 minute).
Heater Current Input: 50 V working (2300 V for 1 minute).
commons.
UL Recognized Component, File #E156876, UL873, CSA 22.2 No. 24
Type 4X Enclosure rating (Face only), UL50
IECEE CB Scheme Test Certificate # UL1369-156876/USA,
Unit is panel mounted in a metal enclosure (Buckeye SM7013-0 or
Power Line and I/O cables routed in metal conduit connected to earth
For operation without loss of performance:
I/O cables routed in metal conduit connected to earth ground.
information.
Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.
CB Scheme Test Report # 96ME50224-040396
IEC 1010-1, EN 61010-1: Safety requirements for electrical equipment
IP65 Enclosure rating (Face only), IEC 529
equivalent) that provides at least 20 dB shielding effectiveness. Metal
panel is connected to earth ground.
ground.
Analog output may deviate during EMI disturbance.
Install power line filter, RLC#LFIL0000 or equivalent.
Install 2 ferrite cores, RLC#FCOR0000 or equivalent, to AC lines at
Issued by Underwriters Laboratories, Inc.
for measurement, control, and laboratory use, Part 1.
unit for frequencies above 5 MHz.
OR
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-6
EN 61000-4-8
ENV 50204
EN 55011
Level 2; 4 Kv contact
Level 3; 8 Kv air
Level 3; 10 V/m
80 MHz - 1 GHz
Level 4; 2 Kv I/O
Level 3; 2 Kv power
Level 3; 10 V/rms
150 KHz - 80 MHz
Level 4; 30 A/m
Level 3; 10 V/m
900 MHz ± 5 MHz
200 Hz, 50% duty cycle
Enclosure class A
Power mains class A
1
2

Related parts for T4811100