UCP-12/4.2-D12 Murata Power Solutions Inc, UCP-12/4.2-D12 Datasheet - Page 4

DC/DC Converter

UCP-12/4.2-D12

Manufacturer Part Number
UCP-12/4.2-D12
Description
DC/DC Converter
Manufacturer
Murata Power Solutions Inc
Series
UCPr
Datasheet

Specifications of UCP-12/4.2-D12

Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Input Voltage
10V To 18V
Power Rating
50W
Output Voltage
12V
Output Current
4.2A
Approval Bodies
EN, UL
Supply Voltage
12V
Product
Isolated
Output Power
50 W
Input Voltage Range
10 V to 18 V
Input Voltage (nominal)
12 V
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
4.2 A
Isolation Voltage
1.5 KV
Package / Case Size
Half Brick
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
60
50
40
30
20
10
60
50
40
30
20
10
60
50
40
30
20
10
0
0
0
–40
–40
–40
Figure 3a. Temperature Derating Without HS-CP Heat Sink
Figure 4a. Temperature Derating Without HS-CP Heat Sink
0
0
0
Figure 2a. Temperature Derating Without Heat Sink
30
30
30
Natural Convection Cooling
150 Linear Feet Per Minute
300 Linear Feet Per Minute
Natural Convection Cooling
150 Linear Feet Per Minute
300 Linear Feet Per Minute
Natural Convection Cooling
150 Linear Feet Per Minute
300 Linear Feet Per Minute
35
35
35
40
40
40
45
45
45
Ambient Temperature (°C)
Ambient Temperature (°C)
Ambient Temperature (°C)
50
50
50
55
55
55
60
60
60
65
65
65
www.murata-ps.com
70
70
70
75
75
75
80
80
80
85
85
85
90
90
90
D48 Models (60 Watts)
D12 Models (50 Watts)
D24 Models (60 Watts)
95
95
95
100
100
100
UL/EN Approved "Half-Brick" 40-75 Watt, DC/DC Converters
60
50
40
30
20
10
60
50
40
30
20
10
60
50
40
30
20
10
0
0
0
–40
–40
–40
0
0
0
Figure 2b. Temperature Derating With HS-CP Heat Sink
Figure 3b. Temperature Derating With HS-CP Heat Sink
Figure 4b. Temperature Derating With HS-CP Heat Sink
30
30
30
Natural Convection Cooling
150 Linear Feet Per Minute
300 Linear Feet Per Minute
Natural Convection Cooling
150 Linear Feet Per Minute
300 Linear Feet Per Minute
Natural Convection Cooling
150 Linear Feet Per Minute
300 Linear Feet Per Minute
35
35
35
Technical enquiries email: sales@murata-ps.com, tel:
40
40
40
45
45
45
Ambient Temperature (°C)
Ambient Temperature (°C)
Ambient Temperature (°C)
50
50
50
55
55
55
60
60
60
65
65
65
MDC_UCP40-75W.B03 Page 4 of 7
UCP Models
70
70
70
75
75
75
80
80
80
85
85
85
+1 508 339 3000
90
90
90
95
95
95
100
100
100

Related parts for UCP-12/4.2-D12