BXA3-48S05J Emerson Network Power, BXA3-48S05J Datasheet - Page 2

DC/DC Converter

BXA3-48S05J

Manufacturer Part Number
BXA3-48S05J
Description
DC/DC Converter
Manufacturer
Emerson Network Power
Datasheet

Specifications of BXA3-48S05J

Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Input Voltage
36V To 75V
Power Rating
5W
Output Voltage
5V
Output Current
500mA
Approval Bodies
CSA, EN, IEC, UL, VDE
Supply Voltage
75V
Product
Isolated
Output Power
3 W
Input Voltage Range
36 V to 75 V
Input Voltage (nominal)
48 V
Number Of Outputs
1
Output Voltage (channel 1)
5 V
Output Current (channel 1)
500 mA
Isolation Voltage
500 V
Package / Case Size
31.8 mm x 15.2 mm 12.7 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Specifications
All specifications are typical at nominal input, full load at 25
OUTPUT SPECIFICATIONS
Voltage accuracy
Line regulation
Load regulation
Ripple and noise
(5 Hz to 20 MHz)
Temperature coefficient
Over voltage protection
Short circuit protection
INPUT SPECIFICATIONS
Input voltage range
Input filter
Reverse voltage
protection
Max. input rise
and fall time
LL to HL, all outputs
Full load to no load
+5 V output
All others
Clamp diode
12 Vdc
24 Vdc
48 Vdc
Suffix ‘-F’ (See Note 5)
(See Note 7)
Output remains within
specification
100 mV pk-pk, max.,
60 mV pk-pk, max.,
automatic recovery
±0.02%/°C, max.
°
Continuous
15 mV rms
15 mV rms
C unless otherwise stated.
135% Vout
18-36 Vdc
36-75 Vdc
9-18 Vdc
5 V/ms
Pi type
±1.0%
±2.5%
±2.5%
Yes
EMC CHARACTERISTICS
Conducted emissions
GENERAL SPECIFICATIONS
Efficiency
Isolation voltage
Switching frequency
Approvals and
standards
Case material
Material flammability
Weight
MTBF
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Relative humidity
Altitude
Vibration
EN55022, FCC part 15
Suffix ‘-F’ versions
(See Notes 5 and 6)
Input/output
Variable
MIL-HDBK-217F
Operating ambient
(See derating curve)
Non-operating amb
Cooling
Non-condensing
Operating
Non operating
5 Hz to 500 Hz
Embedded Power for
Business-Critical Continuity
VDE0805, EN60950, IEC950
UL1950, CSA C22.2 No. 950
2.5 G rms (approx.)
Free air convection
200 kHz to1 MHz
-25 °C to +105 °C
-40 °C to +105 °C
10,000 feet max.
40,000 feet max.
Non-conductive
800,000 hours
15 g (0.53 oz)
UL94V-0 min.
5% to 95% RH
black plastic
See table
500 Vdc
Level A
cooled
Rev.03.07.07
2 of 4