ZA120Y Wiremold, ZA120Y Datasheet - Page 15

Suppressors, Outlet

ZA120Y

Manufacturer Part Number
ZA120Y
Description
Suppressors, Outlet
Manufacturer
Wiremold
Series
ZoneMasterr
Datasheets

Specifications of ZA120Y

Suppressor Type
Outlet Strip
Voltage Rating
120VAC
Operating Voltage Range
120VAC To 208VAC
Peak Surge Current
90kA
Connector Type
Terminal Lugs, 4 Wire (#2 AWG Max.)
Data Line Protection
N
Product
Power Outlet Strips
Breakdown Voltage Vbr
330V
Supply Voltage Min
120VAC
Rohs Compliant
No
Applications
Distribution Boards And Small Service Entrance Locations
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Product
Remote Monitoring Unit
Extended Range Power Filter
Multi-Mode Surge Counter
Internal or Fused Disconnect
u
Description/Specifications
Offers clear audio/visual indication of the status of the surge suppressor unit.
The RMU can be installed adjacent to the suppressor or as a remote
installation. Can also be used as a standalone diagnostic device using NO/NC
dry contacts. Powered locally by a plug-in transformer (included).
• Unit can be ordered separately to supplement existing installations using
Unique ultra high performance, bi-directional filter eliminates a broad
range of load or line generated high frequency noise.
Counts the number of times a surge current is being discharged when a
transient is suppressed. By monitoring surge current, not voltage, the unit
gives a true indication of the actual number of times the protector has
controlled a surge.
EMI/RFI Noise
Attenuation:
Maximum Operating
Voltage (L-N):
Peak Let-Through
Voltage (ANSI/IEEE
C62.41 Cat B3 6kV
Ringwave):
Agency Approval:
Sinewave Tracking:
Part No. ZHRMU
SPECIFICATIONS
Dimensions:
Weight:
Protection Indication:
Fault Indication:
Test Functions:
Silent Function:
Connections:
ACCESSORY
ZHRMU250
ELECTRICAL SPECIFICATIONS
SPECIFICATIONS
LCD Display:
Data Storage:
Count Threshold:
Modes of Measurement:
Multiple Measurement Mode:
600VAC, 200,000 RMS Symmetrical Rating. Fused disconnect features
200,000 AIC fusing.
Options
15
5 1/8" x 4" x 1 1/2"
[13.5cm x 10.2cm x 3.8cm]
Approx. 1 lb.
Bright green LED: Illuminated
Audible alarm. Bright red LED: Illuminated
Switch tests audible alarm
(checks monitoring circuitry)
Switch silences audible alarm
Accepts wires up to #14 AWG
DESCRIPTION
250' cable for Remote Monitoring Unit
-75dB Maximum 100 kHz to 100 MHz
400VAC Rated
200V
UL1283 Listed
Controls transients at any
point on the sinewave
Counts 0 - 99,999
40 years without power
100A surge current
Counts surge currents in normal
mode (L-N), or common mode
(L-G, N-G). Counter can also be
used to count surges on any
one phase.
Counts surge activity and can also
be used to identify which phase
has the most surges.

Related parts for ZA120Y