NLP65-9608GJ ARTESYN, NLP65-9608GJ Datasheet

PSU, OPEN FRAME, 3 OUTPUT, 65W

NLP65-9608GJ

Manufacturer Part Number
NLP65-9608GJ
Description
PSU, OPEN FRAME, 3 OUTPUT, 65W
Manufacturer
ARTESYN
Datasheet

Specifications of NLP65-9608GJ

Power Supply Type
Switch Mode
Power Supply Output Type
Fixed
No. Of Output Channels
3
Input Frequency
63Hz
Output Voltage
5V
Output Current
7.5A
Power Rating
65W
Input Voltage
85VAC To 264VAC
No. Of Outputs
3
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
NLP65 Series
S i n g l e , d u a l a n d t r i p l e o u t p u t
The NLP65 series is a 65 W universal input ac-dc power supply on a 5 x 3 inch card with a
maximum component height of 1.26 inches for use in 1U applications. Each model has the option
of input harmonic current correction in the same package size making the series ideal for product
designs that will need to comply with EN61000-3-2 legislation. The NLP65 provides 65 W of
output power with free air convection cooling which can be boosted to 75 W with 20 CFM of air.
The NLP65, with full international safety approval and the CE mark, meets conducted emissions
EN55022 level B and has immunity compliance to EN61000-4-2,-3,-4, -5, -6. The series is
available in a factory installed enclosure with an IEC connector and output connector on flying
leads plus a cover kit for self-installation is also available as an accessory. The NLP65 series is
designed for use in low power data networking, computer and telecom applications such as hubs,
routers, POS terminals, internet servers, cable modems and PABX’s. This list is not exclusive as
the generic feature set of the NLP65 series with industry standard output configurations provides
a solution for most low power applications including many industrial applications.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
OUTPUT SPECIFICATIONS
Total regulation
(Line and load)
Rise time
Transient response
Temperature coefficient
Overvoltage protection
Short circuit protection
Minimum output current
INPUT SPECIFICATIONS
Input voltage range
Input frequency range
Input surge current
(cold start)
Safety ground
leakage current
Input current
Input fuse
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
ESD air
ESD contact
5.0 x 3.0 inch card and 1.26 inch package (1U applications)
Smallest industry standard package
EN61000-3-2 compliance option (HCC)
Overvoltage and short circuit protection
65 W with free air convection cooling
EN55022, EN55011 conducted emissions level B
EN61000-4-2,-3,-4, -5, -6 immunity compliant
Enclosure and cover kit options
Available RoHS compliant
Main output
Auxiliary outputs
At turn-on
Main output
25% step
at 0.1 A/µs
Main outputs
Cyclic operation
Single and multiple
Universal input,
(See Note 2)
NLP65-76xx
version only
120 Vac
230 Vac
120 Vac, 60 Hz
230 Vac, 50 Hz
120 Vac, with PFC
230 Vac, with PFC
120 Vac, without PFC
230 Vac, without PFC
UL/IEC127
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
(11,12)
max. dev., 1ms max.
250 Vac S 3.15 A
5.0% or 250 mV
recovery to 1%
Perf. criteria 1
Perf. criteria 1
125%, ±10%
(See Note 6)
12-370 Vdc
Continuous
85-264 Vac
±0.02%/°C
1.0 s, max.
1.05 A rms
0.51 A rms
1.40 A rms
0.80 A rms
17 A max.
32 A max.
47-63 Hz
Level B
Level A
0.7 mA
1.4 mA
±2.0%
±5.0%
65-75 W AC/DC Universal Input Switch Mode Power Supplies
EMC CHARACTERISTICS (continued)
Surge
Fast transients
Radiated immunity
Conducted immunity
GENERAL SPECIFICATIONS
Hold-up time
Efficiency
Isolation voltage
Switching frequency
Approvals and
standards
(See Notes 9, 13)
Weight
MTBF
GENERAL SPECIFICATIONS
Thermal performance
(See Notes 1, 3, 10)
Relative humidity
Altitude
Vibration (See Note 5)
Shock
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
120 Vac, 60 Hz
230 Vac, 50 Hz
120 Vac, 65 W
Input/output
Input/chassis
Fixed
MIL-HDBK-217F
Operating ambient,
(See derating curve)
Non-operating
50 °C to 70 °C ambient,
convection cooled
0 °C to 50 °C, ambient,
convection cooled
0 °C to 50 °C ambient,
20 CFM forced air (See Note 10)
Peak (0 °C to +50 °C, 60 s)
Non-condensing
Operating
Non-operating
5-500 Hz
per MIL-STD-810E
File Name: nlp65.pdf Rev (02): 07 Nov 2005
IEC950, UL1950, CCC
SPECIFICATIONS
(11,12)
2 YEAR WARRANTY
EN60950, VDE0805
CSA C22.2 No. 950
150,000 hours min.
-40 °C to +85 °C
10,000 feet max.
30,000 feet max.
100 kHz, ±5 kHz
2.4 G rms peak
5% to 95% RH
0 °C to +70 °C
16 ms @ 65 W
78 ms @ 65 W
Perf. criteria 1
Perf. criteria 1
Perf. criteria 2
Perf. criteria 2
283 g (10 oz)
516.4 Part IV
72% typical
50% load
See table
3000 Vac
1500 Vac
Derate to
60950
65 W
75 W
1

Related parts for NLP65-9608GJ

NLP65-9608GJ Summary of contents

Page 1

... Available RoHS compliant The NLP65 series universal input ac-dc power supply inch card with a maximum component height of 1.26 inches for use in 1U applications. Each model has the option of input harmonic current correction in the same package size making the series ideal for product designs that will need to comply with EN61000-3-2 legislation ...

Page 2

... EMC compliance. When performing conducted emissions testing on stand alone units, the ‘G’ option is required to meet level B. To order simply add the suffix ‘G’ to the standard model number, e.g. NLP65- 7608GJ, NLP65-9608GJ. This option is available for both the PFC and non-PFC versions. 13 All models require a minimum mounting stand-off of 0 ...

Page 3

... Return Return No Connection N/C DERATING CURVE Output Power (Watts) 20 CFM FORCED AIR COOLING NATURAL CONVECTION COOLING 0˚C 10˚C 20˚C 30˚C 40˚C 50˚C 60˚C 70˚C www.artesyn.com File Name: nlp65.pdf Rev (02): 07 Nov 2005 3 TRIPLE V (B) V (A) V (A) Return Return V (C) 38W 32W ...

Related keywords