NLP150L-96Q5366J Emerson Network Power, NLP150L-96Q5366J Datasheet - Page 2

POWER SUPPLY, SWITCH MODE, 5.1V

NLP150L-96Q5366J

Manufacturer Part Number
NLP150L-96Q5366J
Description
POWER SUPPLY, SWITCH MODE, 5.1V
Manufacturer
Emerson Network Power
Datasheet

Specifications of NLP150L-96Q5366J

Power Supply Type
Open Frame
Power Supply Output Type
Fixed
No. Of Outputs
4
Output Voltage
5.1V
Output Current
30A
Power Rating
150W
Input Voltage
90V AC To 264V AC
Length
172.72mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NLP150L-96Q5366J
Manufacturer:
ARTESYN
Quantity:
1 000
NLP150L Series
Notes
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 110-150 W AC/DC Universal Input Switch Mode Power Supplies
Free air convection.
Multiple output units: maximum continuous output power not to exceed
110 W and the output current not to exceed: I
300 LFM forced air cooling from the longer side.
Multiple output units: maximum continuous output power not to exceed
150 W and the output current not to exceed: I
Peak power at 115% lasting less than 30 seconds with duty cycle less than
5%. During peak loading, output voltage may exceed total regulation limits.
Figure is peak-to-peak for room temperature rating. Output noise
measurements are made across a 20 MHz bandwidth using a 6 inch
twisted pair, terminated with a 10 µF electrolytic capacitor and a 0.1 µF
ceramic capacitor.
Minimum load required for correct start-up and operation on single outputs
and on main output of multiple versions. Failure to observe minimum load
on main output will not allow the supply to start-up correctly. Some
electronic test loads have a large delay time before they start drawing
current even though the voltage from the supply is present. During this time
delay, there is no load on the output and as a result, the supply may not be
able to start-up properly and maintain its correct output voltage. In these
instances, a dummy resistive load across the output may be necessary to
load the output of the supply until the test load can function correctly and
draw the intended minimum load. Minimum load required on auxiliary
outputs to maintain regulation.
Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G
rms 5 Hz to 500 Hz.
For optimum reliability no part of the heatsink should exceed 110 °C and
no semi-conductor case temperature should exceed 115 °C.
CAUTION: Allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Conducted EMI specifications reference measurements made with the
power supply mounted on a grounded metal sheet extending 1 inch
beyond each edge, using an unshielded cable. No external filtering required
during conducted emissions testing but some applications may require
additional filtering to achieve system compliance. Compliance with
Radiated EMI specifications may require mounting in a suitable enclosure.
All models require a minimum mounting stand-off of 6.35 mm (0.25 inches)
in the end use product.
Operational range 90 Vac to 264 Vac.
For 3.3 V ouput (single), typical efficiency is 69%.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
+5.1 V (V
+3.3 V (V
+5.1 V (V
+12 V (V
+24 V (V
VOLTAGE
+12 V (V
+12 V (V
OUTPUT
3.3 V (V
5.1 V (V
24 V (V
48 V (V
A
A
A
A
A
C
A
C
A
B
B
)
)
)
)
)
)
)
)
)
)
)
S i n g l e a n d t r i p l e o u t p u t s
MIN
0.15 A
0.3 A
0.1 A
1.5 A
0.5 A
0.6 A
0.5 A
1 A
1 A
0 A
0 A
(5)
OUTPUT CURRENT
MAX
A
A
9.2 A
4.6 A
2.3 A
9.2 A
22 A
22 A
20 A
10 A
+I
+I
2 A
6 A
2 A
B
B
+2(I
+2(I
(1)
C
C
)≤23 A.
)≤32 A.
300 LFM
12.5 A
12.5 A
6.5 A
3.2 A
30 A
15 A
30 A
30 A
3 A
8 A
3 A
(2)
International Safety Standard Approvals
150W
110W
VDE0805/EN60950/IEC950 File No. 10401-3336-0162
Licence No. 123897
UL1950 File No. E136005
0 C
RIPPLE
120 mV
240 mV
480 mV
120 mV
120 mV
240 mV
DERATING CURVE
Output Power (Watts)
50 mV
50 mV
50 mV
50 mV
50 mV
10 C 20 C 30 C 40 C 50 C 60 C 70 C
(4)
300 LFM FORCED
AIR COOLING
CONVECTION
NATURAL
COOLING
REGULATION
TOTAL
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±5.0%
±2.0%
±2.0%
±5.0%
File Name: nlp150lst.pdf Rev (03): 08 Nov 2005
NLP150L-96T536J
NLP150L-96T658J
NUMBERS
NLP150L-96S3J
NLP150L-96S5J
NLP150L-96S6J
NLP150L-96S8J
NLP150L-96S9J
MODEL
75W
55W
(14,15)
2

Related parts for NLP150L-96Q5366J