VS3-D2-G33-H245-00 Emerson Network Power, VS3-D2-G33-H245-00 Datasheet
VS3-D2-G33-H245-00
Specifications of VS3-D2-G33-H245-00
Related parts for VS3-D2-G33-H245-00
VS3-D2-G33-H245-00 Summary of contents
Page 1
... Watts VS Series VS1-B2-H522-00 1100W total VS3-D2-C2-20 1200W total VS6-L2-00 1500W total VS8-L9-D9-20 2500W total (case limit) VS4/9 2000 - 2500 W 1 Technical Support: (888) 41-ASTEC or (407) 241-2752 Americas: (760) 930-4600 Special Features • Power factor correction • IEC 555-2 harmonic distortion compliance • ...
Page 2
... Electrical Specs Input Fuse rating 600 (internal)1Ø 250 (internal)3Ø Input voltage 85-264 VAC 1Ø VS1, VS3 & VS4 (See operating curve) 180-264 VAC 3Ø VS6, VS8 & VS9 Frequency 47 to 440 Hz Inrush current 40 A peak max. Efficiency 75% - 82% Power factor 0.99 typical (0.9 on VS6, VS8 & ...
Page 3
... USE ONLY-FOR MODIFIED STANDARD, CONSULT-FACTORY Indicates CE compliance Parallel Code VS1 and VS6 available slots J1 VS3 and VS8 available slots N J1 VS4 and VS9 available slots N Parallel Codes parallel & & ...
Page 4
... VS3-C2-H332- VS3-D2-B0- VS3-B2-G23-G32- VS3-D2-D0- VS3-D2-G33- VS3-C2-G33-H245- VS3-L2-H332- VS3-D2-G33-H245- VS8-L2-B1-H334-00 Notes: Electrical Characteristics minus nominal output voltage (tracking). 2. Inhibit & Enable are both TTL compatible. ISOLATED requires 2 mA source, typical OK/Converter Run denotes output voltage is present and converters are running (Or'ed signal configuration). ...
Page 5
... NOTES (ALL MODELS) 1. Input: Barrier type. Three No. 6-32 B.H. screws (0.375” centers). For VS1, VS3 & VS4 additional GND CONN added for VS6, VS8 & VS9. Max torque: 10 in-lbs (1.1 N-m). 2. Control connectors: (J1 and J2) 10 position Molex 90130-3210 housing, gold plated contacts. Mates with Molex 90142-0010 housing with 90119-2110 crimp contacts (Molex C - Grid III Series). Connector kit includes mating connector and 10 pins, Astec part #70-841-004. 3. Output terminals (A-300 W) (B-600 W) & ...
Page 6
... Astec House, Waterfront Business Park 5810 Van Allen Way Merry Hill, Dudley Carlsbad, CA 92008 West Midlands, DY5 1LX, UK Telephone: 760-930-4600 Telephone: 44 (1384) 842-211 Facsimile: 760-930-0698 Facsimile: 44 (1384) 843-355 DRAWINGS • VS3 & VS8 • 1000-2500 WATTS .94 MAX 23.89) 5.00 MAX (127.03) Side Back AC Phase A 1 ...
Page 7
Drawings VS4 & VS9 • 2000-2500 WATTS 11-inch Case Size (5” x 11” x 11”) VS4 10.80 ±.20 274.32 ±5.04 (PFC HIGH NEUTRAL GROUND ...
Page 8
Module Front Panels www.astec.com EUROPE AMERICAS Astec House, Waterfront Business Park 5810 Van Allen Way Merry Hill, Dudley Carlsbad, CA 92008 West Midlands, DY5 1LX, UK Telephone: 760-930-4600 Telephone: 44 (1384) 842-211 Facsimile: 760-930-0698 Facsimile: 44 (1384) 843-355 ASIA Units ...