LPS42-T Emerson Network Power, LPS42-T Datasheet

no-image

LPS42-T

Manufacturer Part Number
LPS42-T
Description
5v Output, 40W 3"x 5"
Manufacturer
Emerson Network Power
Datasheet

Specifications of LPS42-T

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Special Features
• Universal input
• 3” x 5” footprint
• Less than 1U high
• Remote sense
• Terminal block option (-T)
• Built-in EMI filter
• Low output ripple
• Adjustable output
• Overvoltage protection
• Overload protection
• 110 KHz switching frequency
• LPX40 enclosure kit available
Safety
LPS40 Series
40 Watts
Total Power:
Input Voltage:
# of Outputs:
UL
CSA CSA 22.2-234 Level 3
NEMKO EN 60950/EMKO-TUE
CB
CE Mark (LVD)
UL60950
E132002
LR53982C
P94100375 (74-sec)203
1119, 1125, 1126, 1127
Certificate and report
40 - 55 Watts
85 - 264 VAC
120 - 300 VDC
Single
Electrical Specifications
Input
Input range:
Frequency:
Inrush current:
Input current:
Efficiency:
EMI filter:
Safety ground
leakage current:
Output
Maximum power:
Adjustment range:
Hold-up time:
Overload protection:
Overvoltage protection: 5 V output; 5.7 to 6.7 VDC. Other outputs 10% to 25% above nominal
Remote sense:
85 - 264 VAC; 120 - 300 VDC
47 - 440 Hz
< 18 A peak @ 115 VAC; < 36 A peak @ 230 VAC, cold start @ 25 °C
1 A max. (RMS) @ 115 VAC
70% typical at full load
FCC Class B conducted; CISPR 22 Class B conducted;
EN55022 Class B conducted; VDE 0878 PT3 class B conducted
< 0.5 mA @ 50/60 Hz, 264 VAC input
40 W for convection; 55 W with 30CFM forced air
-5, +10% minimum
20 ms @ 40 W load, 115 VAC nominal line
Short circuit protection on all outputs
Case overload protected @ 110 -145% above peak rating
output
Compensates for 0.5 V lead drop minimum
Will operate without remote sense connected
Reverse connection protected
Embedded Power for
Business-Critical Continuity
Rev. 7.8.09_4
LPS40 Series
 of 3

Related parts for LPS42-T

LPS42-T Summary of contents

Page 1

LPS40 Series 40 Watts Total Power Watts Input Voltage 264 VAC 120 - 300 VDC # of Outputs: Single Special Features • Universal input • 3” x 5” footprint • Less than 1U high • Remote sense • Terminal block option (-T) • Built-in EMI filter • Low output ripple • Adjustable output • Overvoltage protection • Overload protection • ...

Page 2

... Humidity: Operating; non-condensing 5% to 95% RH Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5Hz to 500Hz, operational MTBF demonstrated: > 550,000 hours at full load and 25 °C ambient conditions Ordering Information Output Minimum Maximum Load with Model Number Voltage Load LPS41(-T) 3 LPS42(- LPS43(- LPS44(- LPS45(- LPS48(- Peak current lasting < 30 seconds with a maximum 10% duty cycle °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. ...

Page 3

... Mechanical Drawing 0.22" 4.55" (5.6) (115.6) GND M1 3.00" (76.2) 2.55" (64. 1.14" (29) 0.197" Pin Assignments Connector LPS41 LPS42 LPS43 SK1-1 Line Line Line SK1-3 Neutral Neutral Neutral SK2-1 +3.3V +5V +12V SK2- 2 +3.3V +5V +12V SK2- 3 +3.3V +5V +12V SK2-4 Common Common Common SK2-5 Common Common Common ...