HDL36040 SQUARE D, HDL36040 Datasheet - Page 36

CIRCUIT BREAKER, THERMAL MAG, 3P, 40A

HDL36040

Manufacturer Part Number
HDL36040
Description
CIRCUIT BREAKER, THERMAL MAG, 3P, 40A
Manufacturer
SQUARE D
Series
PowerPactr
Datasheet

Specifications of HDL36040

Actuator Style
Toggle
No. Of Poles
3
Current Rating
40A
Voltage Rating Vdc
250V
Voltage Rating Vac
600V
Mounting Type
DIN Rail
Terminals
Lug
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
36
PowerPact
Section 3—Accessories
06/2010
®
H- and J-Frame Circuit Breakers
Shunt Trip (MX) and Undervoltage Trip (MN) Switches
A voltage release can be used to trip the circuit breaker via a control signal.
Table 46:
Table 47:
Applications
Installation and
Connection
Operation
Description
Rated Voltage (V)
Consumption
Clearing Time (ms)
Voltage
24 Vac
48 Vac
120 Vac
208-277 Vac
380-480 Vac
525-600 Vac
12 Vdc
24 Vdc
30 Vdc
48 Vdc
60 Vdc
125 Vdc
250 Vdc
Electrical Characteristics
Shunt Trip and Undervoltage Trip Suffix Codes and Kit Numbers
Factory-Installed
Suffix
Shunt trip (MX)
Undervoltage trip (MN)
Pickup (MX)
Seal-in (MN)
Trips the circuit breaker when the control voltage rises above 70% of its rated voltage
Impulse type t 20 ms or maintained control signals
AC shunt trips are suitable for ground fault protection when combined with a Class I ground fault
sensing element
Trips the circuit breaker when the control voltage drops below a tripping threshold
Drops out between 35% and 70% of the rated voltage
Circuit breaker closing is possible only if the voltage exceeds 85% of the rated voltage
Permanent type
If an undervoltage condition exists, operation of the closing mechanism of the circuit breaker will not
permit the main contacts to touch, even momentarily. This is commonly called “Kiss Free”
Accessories are common to H- and J-frame circuit breakers and snap into cavities under the front
accessory cover of the circuit breaker
Each terminal may be connected by one #18–#14 AWG (1.0–2.5 mm
The circuit breaker must be reset locally after being tripped by shunt trip or undervoltage trip (MN or MX)
MN or MX tripping has priority over manual (or motor operator) closing; in the presence of a standing trip
order such an action does not result in any closing, even temporarily, of the main contacts
Endurance: 50% of the rated mechanical endurance of the circuit breaker for circuit breakers
SK
SA
SD
SH
SN
SO
SU
SP
SV
SR
SS
SL
SJ
Shunt Trip
Field-Installable
Kit No.
S29384
S29385
S29386
S29387
S29388
S29389
S29382
S29390
S29391
S29392
S29383
S29393
S29394
AC
24, 48, 110.130, 208.277, 380.480, 525, 600
< 10 VA
< 5 VA
< 50
Factory-Installed
Suffix
Undervoltage Release UVR
UK
UA
UD
UH
UN
UO
UU
UP
UV
UR
US
UL
UJ
Field-Installable
Kit No.
S29404
S29405
S29406
S29407
S29408
S29409
S29402
S29410
S29411
S29412
S29403
S29413
S29414
© 2004–2010 Schneider Electric
2
DC
12, 24, 30, 48, 60, 125, 250
< 5 W
< 5 W
< 50
) stranded copper wire
All Rights Reserved