H3FA-AU DC24 Omron, H3FA-AU DC24 Datasheet

TIMER

H3FA-AU DC24

Manufacturer Part Number
H3FA-AU DC24
Description
TIMER
Manufacturer
Omron
Type
Solid State Timerr
Datasheet

Specifications of H3FA-AU DC24

Analog / Digital
Analog
Control Method
Dial
Voltage Rating
24 VDC
Mounting
PCB
Display Type
None
Size
36.9 mm x 17.75 mm x 19.5 mm
Features
Timer operation may also be controlled through an external variable resistor
Input Type
Voltage
Output Type
SPST-NO and SPST-NC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Please read and understand this catalog before purchasing the products. Please consult OMRON representative if you have any questions or
comments. Refer to Safety Precautions on page 9.
DIP Model Timer for PC Board Use Provides
Contact and Solid-state Output
• Four time ranges are selectable.
• Timer operation may also be controlled through an external
• Timer can be cleaned while mounted on a PC Board with the
• Twenty-four-pin IC socket can be used for mounting the Timer.
• Mountable on a 1-inch pitch rack.
Model Number Structure
Note: This model number legend includes combinations that are not available. Before ordering, please check the List of Models on page 2 for
1. Time-limit contact
2. Time range
3. Operation/resetting system
H3FA- @ @ @ @
Models suffixed -@A@: 1 s, 10 s, 1 min, 10 min.
Models suffixed -@B@: 6 s, 60 s, 6 min, 60 min.
variable resistor.
sealing tape affixed.
(H 19.5 × W 36.9 × D 17.75 mm)
Solid-state Timer
H3FA
None: Contact outputs (SPST-NO + SPST-NC)
S:
A:
B:
None: Time-limit operation/power-OFF resetting and external
U:
availability.
Solid-state outputs
1 s to 10 min
6 s to 60 min
resetting, Integrating operation/power-OFF resetting and
external resetting
Instantaneous operation, time-limit resetting/external
resetting
1 2
3
4
4. Supply voltage
For contact output models
5DC:
6DC:
12DC:
24DC:
For solid-state output models
5/6DC:
12/24DC: 12/24 V DC
5 V DC
6 V DC
12 V DC
24 V DC
5/6 V DC
CSM_H3FA_DS_E_3_1
1

Related parts for H3FA-AU DC24

H3FA-AU DC24 Summary of contents

Page 1

... Mountable on a 1-inch pitch rack. (H 19.5 × W 36.9 × D 17.75 mm) Model Number Structure Note: This model number legend includes combinations that are not available. Before ordering, please check the List of Models on page 2 for availability. H3FA Time-limit contact None: Contact outputs (SPST-NO + SPST-NC) ...

Page 2

... H3FA-SB H3FA-SBU Note: 1. The above timing ranges apply when the internal variable resistor of H3FA is used. 2. The external variable resistor may also be used by opening the terminal connected to the internal variable resistor. 3. Wire the appropriate terminal to select a time setting range. Refer to Rated Time and Terminal Connections on page 4 for details. ...

Page 3

... H3FA H3FA-SA/ H3FA-SB H3FA-SAU/ H3FA-SBU 90% to 110% of rated supply voltage 85% to 110% of rated supply voltage approx approx. 100 mW approx. 240 mW 3 ...

Page 4

... Note: 1. Short-circuit terminals 21 and 22 when using the internal variable resistor of H3FA external resistor can also be used by opening terminals 21 and 22. When using an external resistor (1 MΩ for H3FA-A/-SA, 3 MΩ for H3FA-B/ -SB), connect it between terminals 21 and 23. The voltage across the H3FA-SA and -SB (solid-state output loads) is the load input voltage minus the residual voltage when the transistor turns ON ...

Page 5

... Timing Charts and External Connections Note: Do not apply voltage to any terminals other than the power supply terminals. Otherwise, the internal circuits may be damaged. H3FA-A, H3FA-B, H3FA-SA, H3FA-SB Standard Operation (ON-delay operation) When the power is turned ON and the set time has elapsed, an output is produced ...

Page 6

... H3FA-AU, H3FA-BU, H3FA-SAU, H3FA-SBU One-shot Output Operation Turn ON the power and apply a start input (short terminals 6 and 1). (Power turns ON when power terminals 1 and 24 are shorted or when terminals 13 and 15 are shorted when using a 12/24 V DC- operated model with power supply.) An output is produced immediately and is reset when the set time has elapsed ...

Page 7

... Refer to the following characteristics diagrams when using an external resistor. • Use an external resistor rated at about 0.1 W/1 MΩ for H3FA-A, -SA, -AU, and -SAU or 0.1 W/3 MΩ for H3FA-B, -SB, -BU, and - SBU. • Do not run leads parallel to power lines and keep the leads shorter than minimize the effects of external noise. • ...

Page 8

... Dimensions Note: All units are in millimeters unless otherwise indicated. H3FA-A, H3FA-B, H3FA-SA, H3FA-SB 17.75 19.5 0.5 15.24 3.3 Applicable Connecting Socket Standard 24-pin IC socket can be used to mount the Timer. H3FA-AU, H3FA-BU, H3FA-SAU, H3FA-SBU 17.75 19.5 0.5 15.24 3.3 Applicable Connecting Socket Standard 24-pin IC socket can be used for mounting the Timer ...

Page 9

... Do not operate the H3FA in locations subject to sudden or extreme changes in temperature, or locations where high humidity may result in condensation. • Do not use the H3FA in locations subject to vibrations or shock. Extended use in such locations may result in damage due to stress. • Do not use the H3FA in locations subject to excessive dust, corrosive gas, or direct sunlight ...

Page 10

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...