G308C100 Red Lion Controls, G308C100 Datasheet - Page 3

no-image

G308C100

Manufacturer Part Number
G308C100
Description
DSTN Indoor No USB Host Non-isolated Comms
Manufacturer
Red Lion Controls
Type
Color Graphicr
Datasheet

Specifications of G308C100

Brand/series
G3 Series
Communication
Extensive List of Industrial Devices
Dimensions
10.32 × 8.18
Display Size
7.5 In.
Memory
32 Mb Flash
Mounting Type
Panel
Port Style
RS-232/422/485 and Ethernet
Primary Type
Operator Interface
Resolution
640 × 480
Resolution, Display
640 × 480
Size
7.5" Color TFT
Special Features
Web-Server, UL and Class I Div.2
User Interface
Touchscreen
Voltage, Supply
24 V
Configuration Is Stored In Non-volatile Memory
4 Mbyte Flash for G306M
Lead Free Status / Rohs Status
RoHS Compliant part
For Use With
PLCs, Motor Drives and other Industrial Devices
MOUNTING INSTRUCTIONS
out diagram and a template are provided. Care should be taken to remove any
loose material from the mounting cut-out to prevent that material from falling
into the operator interface during installation. A gasket is provided to enable
sealing to NEMA 4X/IP66 specification. Install the 14 kep nuts provided and
tighten evenly for uniform gasket compression.
N-m) may cause damage to the front panel.
CONNECTING TO EARTH GROUND
should be connected to earth ground (protective earth).
screws for attaching the option card to the G3’s main board.
cables from the unit and remove the rear cover. Connect the cable from the
option card to the connector on the main board. Be sure both ends of the
cable are firmly seated into their appropriate connector housings. Use the
three screws provided to mount the option card to the main board as shown
in Figure 1.
removing the rear cover.
I
I
This operator interface is designed for through-panel mounting. A panel cut-
Note: Tightening the kep nuts beyond a maximum of 17 inch-pounds (1.92
Each G308 has a chassis ground terminal on the back of the unit. Your unit
Each option card comes with a cable for communications and three
To install the option card, remove all power and I/O communications
Carefully replace the rear cover by reversing the instructions for
NSTALLING AND
NSTALLING
ALL NONINCENDIVE CIRCUITS MUST BE WIRED USING
DIVISION 2 WIRING METHODS AS SPECIFIED IN THE NATIONAL
ELECTRICAL CODE, NFPA 70 FOR INSTALLATION WITHIN THE
UNITED STATES, OR AS SPECIFIED IN THE CANADIAN
ELECTRICAL CODE FOR INSTALLATION IN CANADA.
WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT
EQUIPMENT UNLESS POWER HAS BEEN DISCONNECTED
AND THE AREA IS KNOWN TO BE NON-HAZARDOUS.
The protective conductor terminal is bonded to conductive
parts of the equipment for safety purposes and must be
connected to an external protective earthing system.
9.115 (231.5)
9.75 (247.7)
3.25 (82.6)
All tolerances ±0.010" (±0.25 mm).
A
N
(177.3)
O
6.98
P
10X Ø .188 (Ø 4.8)
(193)
PTION
7.60
OWERING THE
C
3
ARD
Maintaining isolation between earth ground and signal common is not required
to operate your unit. But, other equipment connected to this unit may require
isolation between signal common and earth ground. To maintain isolation
between signal common and earth ground care must be taken when connections
are made to the unit. For example, a power supply with isolation between its
signal common and earth ground must be used. Also, plugging in a USB cable
may connect signal common and earth ground.
POWER SUPPLY REQUIREMENTS
requires a 24 VDC power supply rated at 27 W. Your unit may draw considerably
less the rated power depending upon the options being used. As additional
features are used your unit will draw increasing amounts of power. Items that
could cause increases in current are additional communications, optional
communications card, CompactFlash card, and other features programmed
through Crimson.
the unit is to operate reliably. Please take care to observe the following points:
The chassis ground is not connected to signal common of the unit.
1.
The G308C1 requires a 24 VDC power supply rated at 13 W, and the G308A2
In any case, it is very important that the power supply is mounted correctly if
TYPICAL EXPANSION CARD INSTALLATION
USB’s shield may be connected to earth ground at the host. USB’s shield in
turn may also be connected to signal common.
– The power supply must be mounted close to the unit, with usually not
– The wire used to connect the operator interface’s power supply should
– A power supply with an NEC Class 2 or Limited Power Source (LPS)
more than 6 feet (1.8 m) of cable between the supply and the operator
interface. Ideally, the shortest length possible should be used.
be at least 22-gage wire. If a longer cable run is used, a heavier gage
wire should be used. The routing of the cable should be kept away from
large contactors, inverters, and other devices which may generate
significant electrical noise.
and SELV rating is to be used. This type of power supply provides
isolation to accessible circuits from hazardous voltage levels generated
by a mains power supply due to single faults. SELV is an acronym for
“safety extra-low voltage.” Safety extra-low voltage circuits shall
exhibit voltages safe to touch both under normal operating conditions
and after a single fault, such as a breakdown of a layer of basic
insulation or after the failure of a single component has occurred.
WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT
Figure 1
EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA
IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS.
G308
1

Related parts for G308C100