09 12 003 3101 HARTING, 09 12 003 3101 Datasheet

Sealed Ethernet Connector

09 12 003 3101

Manufacturer Part Number
09 12 003 3101
Description
Sealed Ethernet Connector
Manufacturer
HARTING
Datasheet

Specifications of 09 12 003 3101

Connector Type
Sealed Ethernet
Lan Category
Cat5
No. Of Ports
1
Leaded Process Compatible
Yes
Gender
Receptacle
Performance Category
Cat 5e
Usoc Codes
RJ45
Shielding
Unshielded
Housing Material
Plastic
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Han
00 .
02
Economic
and Reliable
Connections
Specifications
VDE 0110 table 4, concerning clearance
VDE 0627 Connectors
DIN EN 61 984
Note:
The connectors included in this ca-
talogue should not be coupled or de-
coupled under electrical load unless
otherwise stated.
The provision of protection against
electric shock is the responsibility of
the user. Protection can be achieved
by the use of HARTING hoods and
housings coupled with/or alternatively
appropriate installation methods provi-
ded by the user.
The female connector in a HARTING
hood or housing offers finger safe pro-
tection according to relevant standards
for the mating face, even in the unma-
ted condition, unless otherwise stated.
Connectors of the same or different
series being mounted side by side
may be protected against incorrect
mating by the use of coding options.
Standard
DIN EN 175 301-801
Approvals
UL File No . E 23 50 76 (www .ul .com)
CSA File No . LR 18 753, SEV
for inserts
General information
It is the customer's responsibility to
check whether the components illus-
trated in this catalogue comply with
different regulations from those stated
in special fields of application which
we are unable to foresee .
© HARTING Electric GmbH & Co . KG, Espelkamp – All rights reserved, including those of the translation .
Certified according to EN ISO 9001
in design/development, production,
Industrie-Steckverbinder
Industrial Connectors Han
installation and servicing
and creepage distances
We reserve the right to modify designs
in order to improve quality, keep pace
with technological advancement or
meet particular requirements in pro-
duction .
®
Anschlusstechnik
Terminations
• Schraubanschluss
• Screw terminal
• Crimpanschluss
• Crimp terminal
• Käfigzugfederanschluss
• Cage-clamp terminal
• Wickelanschluss
• Wrap terminal
• Lötanschluss
• Solder terminal
• Axialschraubanschluss
• Axial-screw terminal
• Schnellanschluss
• Rapid terminal
• Schneidklemmanschluss
• IDC termination
Kontakteinsätze
Inserts
• Voreilende Schutzkontakte
• Leading protective ground
• Sicherung gegen fehlpolarisiertes
• Polarised for correct mating
• Interchangeability of male and female
• Montage wahlweise in Gehäuseober-
• Captive fixing screws
• Unverlierbare Befestigungsschrauben
• Can be used with hoods and housings,
• Verwendbarkeit in Gehäusen
Hoods/Housings
Gehäuse
• Standard Hoods/Housings
• Standard-Gehäuse
• Hoods/Housings for harsh environmen-
• Gehäuse für erhöhte Umwelt-
• Hoods/Housings for intrinsically safe
• Gehäuse für eigensichere elektrische
• Degree of protection IP 65
• Strahlwassergeschützt IP 65
• Electrical connection with protective
• Leitende Verbindung
• High mechanical strength and vibration-
• Hohe mechanische Sicherheit auch
• Spring-loaded covers in shockproof
• Federnd schließende Abdeckkappen
Accessories
Zubehör
• Extensive range of cable protection
• Umfangreiche Kabelverschraubungen
• Protective covers available
• Separat lieferbare Abdeckkappen
• Unterschiedliche Codierungs-
• Coding options for incorrect mating
Stecken
inserts in hoods and housings
oder -unterteilen
or for rack and panel applications
und Einschüben
tal requirements
anforderungen
plant
Anlagen
ground
mit dem Schutzkontakt
resistance ensured by locking levers
bei Rüttel- und Stoßbelastung durch
Verriegelungsbügel
thermoplastic or metal covers, both
lockable
aus schlagfestem Kunststoff oder
Metall, beide verriegelbar
and sealing accessories
möglichkeiten
protection
No part of this catalogue may be reproduced in any
form (print, photocopy, microfilm or any other proc-
ess) or processed, duplicated or distributed by means
of electronic systems without the written permission of
HARTING Electric GmbH & Co . KG, Espelkamp . We are
bound by the German version only .
For "non standard applications" we can
manufacture designs to match your
requirements .
Please discuss requirements with us .
HARTING components help you
to construct top quality products
– economically and in line with market
requirements .

Related parts for 09 12 003 3101

09 12 003 3101 Summary of contents

Page 1

... HARTING Electric GmbH & KG, Espelkamp – All rights reserved, including those of the translation . ® Anschlusstechnik Terminations • Schraubanschluss • Screw terminal • Crimpanschluss • ...

Page 2

... Hoods/housings connector insert protection . . . . . . . . . . . . . . . . . . . . . . . . Summary hoods/housings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Summary locking systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hoods/Housings variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Termination technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical engineering data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Current Carrying Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cross Reference from PG thread to metric cable thread . . . . . . . . . . . . . . Declaration of Comformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Visit our homepage: www.HARTING.com ® – Technical Characteristics Page 00.05 Han 00.06 00.07 00.08 00.09 00 ...

Page 3

Notes Han ...

Page 4

... The drawings to every single part are available in PDF-format . The parts are downloadable in 2D-format (DXF) and 3D-format (IGES, STEP) . The 3D-models can be viewed with a VRML-viewer . You can find HARKIS our homepage www.HARTING.com . It is ® also available on CD-Rom and DVD . Part configuration CAD library ...

Page 5

Summary Han ® – Size Size Description A Hood Han 230/400 Han ® Staf 6 chapter 01 chapter ...

Page 6

Summary Han ® – Size Size Description B Hood side-entry 250 V 250 Han D ® Han DD ® chapter 02 chapter 02 ...

Page 7

How to order For a complete connector components may be ordered from the following sub headings Han Cable entry protection Universal cable glands Special cable clamp with strain relief, bell mouthed cable fitting and anti-twist devices Cable gland with normal ...

Page 8

Hoods/housings connector insert protection The connector’s housing, sealing and locking mechanism protect the connection from external influences such as mechanical shocks, foreign bodies, humidity, dust, water or other fluids such as cleansing and cooling agents, oils, etc . The degree ...

Page 9

Summary Hoods/Housings Standard Hoods/Housings Field of application for excellent mechanical and electrical protection in demanding environments, Han for example, in the automobile and mechanical engineering industries also for process and regulation control appli- cations Distinguishing feature hoods/housings colour-coded grey (RAL ...

Page 10

Summary locking systems Housing with 2 levers Han-Easy Lock ® ❑ easy operation ❑ high degree of pressure tightness ❑ reliable locking guaranteed by 4 locking points ❑ space saving mounting ❑ ideal for mounting side by side ❑ cable ...

Page 11

Hoods/Housings variants Han-INOX ® Hoods/Housings Field of application for excellent mechanical and electrical protection in demanding environments, for example, in the Han food, automobile and mechanical engineering industries also for process and regulation control appli- cations Distinguishing feature matt-finished metal ...

Page 12

Terminations Screw terminal Screw terminals meet VDE 0609 /EN 60 999. Dimensions and tightening torques for testing are shown in following table. Screw dimensions and tightening torque for screw terminals Wire gauge (mm²) 1.5 2.5 4 Screw thread M3 M3 ...

Page 13

... DIN IEC 60 352, part 2, defines the extraction force in relation to the cross-section of the conductor. When fitted using HARTING crimping tools and subject to their utilization in an approved manner, our crimp connectors comply with the required extraction forces. ...

Page 14

Terminations Axial screw terminal This termination combines the benefits of screw and crimp termi- nations: ● Less space required ● Easy handling ● No special tools Remarks on the axial screw technique The wire gauges mentioned in the catalogue refer ...

Page 15

Terminations Insert Han Han ® K 4/4 finger proofed Han ® K 4/4 Han ® K 6/12 Han ® K 6/6 Han ® K 8/0 Han ® Q 2/0 Han ® Q 2/0 High Voltage Han ® 200 A module ...

Page 16

Terminations Insert Wire gauge (mm²) Han ® K3/0 angled 35 – 70 Han ® K3/2 straight 35 – 70 Han ® K3/2 angled 35 – 70 Han ® HC Modular 350 35 – – 120 Ground contact for ...

Page 17

Terminations Cage-clamp terminal Han This termination method requires very little preparation of the wire and no special tools, leading to a low installed cost and a high degree of mechanical security. ● For all stranded and solid wires with a ...

Page 18

... The overvoltage category affects the dimensioning of components in that it determines the clearance air gap . Pursuant to the relevant standards, there are 4 overvoltage categories . Equipment for industrial use, such as fall HARTING heavy duty Han connector, fall into Overvoltage Category III. Rated impulse voltages (Table 5 of DIN EN 61 984) ...

Page 19

... The pollution degree is defined for exposed, unprotected insula- tion on the basis of environmental conditions . HARTING heavy duty Han connectors are designed as stand- ard for Pollution Degree 3. Pollution degree 1 in air-conditioned or clean, dry rooms, such as computer and measuring instrument rooms, for example ...

Page 20

... Protection levels as per IEC 60 529 The protection level describes the leak-proof character of hous- ing for electrical equipment . It ranges from HARTING heavy duty Han connectors feature a standard protec- tion level (see page 00 .09, Table based on DIN VDE 0470, DIN EN 60 529, IEC 60 529) . ...

Page 21

Current carrying capacity Current carrying capacity The current carrying capacity is determined in tests which are conducted on the basis of the DIN IEC 60 512 part 5 . The current Han carrying capacity is limited by the thermal properties ...

Page 22

... In systems where such a change to the transmitted signal could lead to faulty functions and also in extremely aggressive environ- ments, HARTING recommend the use of gold plated contacts . Changes to the transmitted signal after artifical ageing ➀ new contact ➁ ...

Page 23

Cross Reference from PG thread to metric cable thread The reason for the new product offerings is the publication of the international DIN EN 50262 metric thread specification . The existing PG series will be, ...

Page 24

Declaration of Conformity Han ...

Page 25

Notes Han ...

Related keywords