ZICM357P2-1-B CEL, ZICM357P2-1-B Datasheet - Page 14

MOD EM357 ZIG 802.15.4 PCB ANT

ZICM357P2-1-B

Manufacturer Part Number
ZICM357P2-1-B
Description
MOD EM357 ZIG 802.15.4 PCB ANT
Manufacturer
CEL
Datasheet

Specifications of ZICM357P2-1-B

Frequency
2.405GHz ~ 2.475GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4 Zigbee
Applications
Home/Building Automation, Security, ZigBee™
Power - Output
20dBm
Sensitivity
-100dBm
Voltage - Supply
2.7 V ~ 3.6 V
Current - Receiving
28mA
Current - Transmitting
170mA
Data Interface
PCB, Surface Mount
Memory Size
192kB Flash, 12kB RAM
Antenna Connector
On-Board, Trace
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Wireless Frequency
2483.5 MHz
Interface Type
SPI, TWI, UART
Security
AES
Operating Voltage
3.6 V
Output Power
20 dBm
Antenna
PCB Trace
Operating Temperature Range
- 40 C to + 85 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
EM357
Other names
ZICM357P2-1
ZICM357P2-1
AGENCY CERTIFICATIONS
Software Compliance
The ZICM357P2-1 requires software restrictions to meet agency certification requirements. These restrictions have been
implemented in the sample application included with the software development kit.
If a customer is not starting with CEL's software development kit, they must implement these output power restrictions to
use the ZICM357P2-1 FCC, IC or ETSI certification:
Note:
SHIPMENT, HANDLING, AND STORAGE
Shipment
The MeshConnect Modules are delivered in trays of 28.
Handling
The MeshConnect Modules are designed and packaged to be processed in an automated assembly line.
Warning
protection may destroy or damage the module permanently.
Warning
summarized in J-STD-033. Read carefully to prevent permanent damage due to moisture intake.
Moisture Sensitivity Level (MSL)
MSL 3, per J-STD-033
Storage
Storage/shelf life in sealed bags is 12 months at <40°C and <90% relative humidity.
QUALITY
CEL modules offer the highest quality at competitive prices. Our modules are manufactured in compliance with the IPC-A-610
specification, Class II. Our modules go through JESD22 qualification processes which includes high temperature operating life
tests, mechanical shock, temperature cycling, humidity and reflow testing. CEL conducts 100% RF and DC factory testing on
all production parts and also conducts sample testing on all device lots.
CEL’s builds the quality into our products giving our customers the confidence when integrating our products into their systems.
The software development kit does not implement the ETSI restrictions.
The MeshConnect Modules contain highly sensitive electronic circuitry. Handling without proper ESD
The MeshConnect Modules are moisture-sensitive devices. Appropriate handling instructions and precautions are
Certification
FCC/IC
ETSI
(Continued)
RF Channel
11 - 23
11 - 26
24
25
26
Valid TX Power Steps
-43 to -14
-43 to -14
Disabled
-43 to -5
-43 to 8
MeshConnect™ EM357 Module
Page 14