AEDA-3300-TAT Avago Technologies US Inc., AEDA-3300-TAT Datasheet - Page 4

M-Aries Kit,3Ch,4096CPR,Top Mt

AEDA-3300-TAT

Manufacturer Part Number
AEDA-3300-TAT
Description
M-Aries Kit,3Ch,4096CPR,Top Mt
Manufacturer
Avago Technologies US Inc.
Series
AEDA-3300r
Datasheet

Specifications of AEDA-3300-TAT

Encoder Type
Optical
Output Type
Quadrature with Index (Incremental)
Pulses Per Revolution
4096
Voltage - Supply
5VDC
Actuator Type
2mm Open Center
Detent
No
Built In Switch
No
Mounting Type
Chassis Mount, Motors
Orientation
Vertical
Termination Style
Terminal Pins
Number Of Channels
3
Mounting Style
PCB
Supply Voltage
5 V
Product
Kits
Technology
Rotary
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Rotational Life (cycles Min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Absolute Maximum Ratings
Note: Absolute Maximum Ratings are those values beyond which the safety of the device cannot be guaranteed. They are not meant to imply that the
device should be operated at these limits. The tables “Recommended Operating Conditions and Characteristics” provide conditions for actual device
operation.
Recommended Operating Conditions
Encoding Characteristics
Encoding characteristics over recommended operating conditions. Typical values represent maximum values at 25°C and
2000 RPM (1000 RPM for options above 10 000 CPR). See Output Waveform for the definitions of the errors.
Notes:
1. Applicable for CPR options of up to and include 4096 CPR
2. Applicable for CPR options from 5000 CPR, up to and include 10 000 CPR
3. Applicable for CPR options of above 10 000 CPR, and up to 20 000 CPR
4
Parameter
Pulse Width Error
State Width Error
Phase Error
Index Pulse Width Error
Storage Temperature
Operating Temperature
Supply Voltage
Output Voltage
Output Current per Channel
Max Frequency
Parameter
Supply Voltage
Frequency
Temperature
Symbol
T
V
f
A
CC
Min.
-40
4.5
Symbol
P
S
Po
25
5
Typical
125
1.0
1 MHz
Max.
5.5
650
-40 to 125 °C
-40 to 125 °C
4.5 V to 5.5 V
-0.5 V to Vcc
20 mA
15
Typical
30
45
55
25
30
50
20
25
30
25
40
Units
MHz
kHz
V
C
Max.
45
60
70
40
50
60
20
30
35
20
45
45
Notes
1.
2.
3.
4.
For CPR options of 10 000 CPR and
below
Gated by maximum rotational speed
of 12000 RPM. Refer to section
Maximum Frequency and RPM.
For CPR options above 10 000 CPR
and up to 20 000 CPR
Please consult factory for special
requirements of higher operating
frequency
Units
°e
°e
°e
°e
Remarks
See Note 1
See Note 2
See Note 3
See Note 1
See Note 2
See Note 3
See Note 1
See Note 2
See Note 3
See Note 1
See Note 2
See Note 3

Related parts for AEDA-3300-TAT