AEDA-3300-TAT Avago Technologies US Inc., AEDA-3300-TAT Datasheet - Page 5

M-Aries Kit,3Ch,4096CPR,Top Mt

AEDA-3300-TAT

Manufacturer Part Number
AEDA-3300-TAT
Description
M-Aries Kit,3Ch,4096CPR,Top Mt
Manufacturer
Avago Technologies US Inc.
Series
AEDA-3300r
Datasheet

Specifications of AEDA-3300-TAT

Encoder Type
Optical
Output Type
Quadrature with Index (Incremental)
Pulses Per Revolution
4096
Voltage - Supply
5VDC
Actuator Type
2mm Open Center
Detent
No
Built In Switch
No
Mounting Type
Chassis Mount, Motors
Orientation
Vertical
Termination Style
Terminal Pins
Number Of Channels
3
Mounting Style
PCB
Supply Voltage
5 V
Product
Kits
Technology
Rotary
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Rotational Life (cycles Min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Electrical Characteristics Table
Electrical characteristics over recommended operating conditions. Typical values at 25°C
Mechanical Characteristics
Note: 1. This value represents the maximum mechanical permissible shaft speed of the kit encoder. However, for options with CPR > 5000, the maximum
shaft speed is limited by the maximum electrical frequency. Refer to Table Maximum Frequency and RPM for the comparison of the possible operable
frequency and RPM.
Mechanical and Environmental Tests
Note: Any mechanical shock and vibration exceeding the stated values may cause damage to the encoder. The encoder should not be subjected to
excessive mechanical shock and vibration either during installation or operation.
5
Parameter
Supply Current
High level Output Voltage
Low level Output Voltage
Parameter
Standard Shaft Diameters
Mounting Screw Size:
Bottom-up (threaded mount)
Bearing material
Maximum RPM
Maximum Axial Load
Maximum Radial Load
Maximum Initial Torque
Bearing Life
Shock (non-operating)
ESD
Electromagnetic Compatibility
(EMC)
Humidity
Top-down (coupling plate)
Weight
Test Name
Vibration (non-operating)
1.998
M2
M2
12
bearing
12000
Dimension/Details Tolerance
Stainless Steel
miniature precision
8
8
3 x 10
3
Reference
IEC 68-2-64
IEC68-2-27
IEC 61000-4-2
IEC61000-4-4
IEC-68-2-3
I
Symbol
V
V
CC
OH
OL
-3
Minimum
2.5
+0/-.01
(+0/-.0005)
Conditions
100G at 10ms
Repetition = 300 ms, Test Points = ±1000 & ±1500V
5-2000Hz at 20G for 6-axis
4kV
Spike Frequency = 5KHz, Duration = 15ms,
85 % RH (Non-condensing)
55
3.4
0.3
Typical
N
Nm
Units
mm
(in)
g
N
Years
Maximum
100
0.5
Remarks
See Note 1
Based on data provided by
bearing manufacturer.
Based on data provided by
bearing manufacturer.
Based on manufacturer's data.
At 25 °C
24 hours continuous testing,
at 125 °C and maximum RPM.
Units
mA
V
V
Notes

Related parts for AEDA-3300-TAT