Task Management
This task is used for toggling state of PLC coil or register bit. The bit/coil should be a read-write coil.
This task is executed on coil or bit-addressed register only. User can select coil or bit-addressed register
from tag list.
When this task is executed, the bit/coil is set to 1 if it was 0 previously and vice-versa.
For this task default setting is shown under ‘Bit operations’. If user change this selection, task will be
changed.
Click ‘OK’ to add task in task list.
This task is used for copying value of one PLC tag to Other PLC tag. The value of tag B will be un-
changed. Tag A will be same as tag B.
E.g..- Tag A = Tag B
This task is executed on register tags and coil or bit-addressed register listed under Tag option. Both tag
type must be of same type; either register type or coil/bit type. If the selected tags are of register type
than this command is executed depending on the tag length (i.e. 1 byte,2 byte, 4 byte ).
For this task default setting is shown under ‘Common operations’. If user change this selection, task will
be changed. Click ‘OK’ to add task in task list.
122
Toggle bit
Copy Tag B to Tag A