AD9516-2BCPZ Analog Devices Inc, AD9516-2BCPZ Datasheet - Page 39

IC,Ten Distributed-Output Clock Driver,LLCC,64PIN,PLASTIC

AD9516-2BCPZ

Manufacturer Part Number
AD9516-2BCPZ
Description
IC,Ten Distributed-Output Clock Driver,LLCC,64PIN,PLASTIC
Manufacturer
Analog Devices Inc
Type
Clock Generator, Fanout Distributionr
Datasheet

Specifications of AD9516-2BCPZ

Pll
Yes
Input
Clock
Output
CMOS, LVDS, LVPECL
Number Of Circuits
1
Ratio - Input:output
1:14
Differential - Input:output
Yes/Yes
Frequency - Max
2.33GHz
Divider/multiplier
Yes/No
Voltage - Supply
3.135 V ~ 3.465 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
64-LFCSP
Frequency-max
2.33GHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
AD9516-2/PCBZ - BOARD EVAL FOR AD9516-2 2.2GHZ
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD9516-2BCPZ
Quantity:
285
VCO Calibration
The AD9516 on-chip VCO must be calibrated to ensure proper
operation over process and temperature. The VCO calibration
is controlled by a calibration controller running off of a divided
REFIN clock. The calibration requires that the PLL be set up
properly to lock the PLL loop and that the REFIN clock be present.
During the first initialization after a power-up or a reset of the
AD9516, a VCO calibration sequence is initiated by setting
Register 0x018[0] = 1b. This can be done as part of the initial
setup, before executing update registers (Register 0x232[0] = 1b).
Subsequent to the initial setup, a VCO calibration sequence is
initiated by resetting Register 0x018[0] = 0b, executing an update
registers operation, setting Register 0x018[0] = 1b, and executing
another update registers operation. A readback bit, Bit 6 in
Register 0x01F, indicates when a VCO calibration is finished
by returning a logic true (that is, 1b).
The sequence of operations for the VCO calibration is as follows:
Program the PLL registers to the proper values for the
PLL loop. Note that that automatic holdover mode
must be disabled, and the VCO divider must not be
set to “Static. ”
Ensure that the input reference signal is present.
For the initial setting of the registers after a power-up or
reset, initiate VCO calibration by setting Register
0x018[0] = 1b. Subsequently, whenever a calibration is
desired, set Register 0x018[0] = 0b, update registers;
and then set Register 0x018[0] = 1b, update registers.
A SYNC operation is initiated internally, causing the
outputs to go to a static state determined by normal
SYNC function operation.
VCO calibrates to the desired setting for the requested
VCO frequency.
Internally, the SYNC signal is released, allowing
outputs to continue clocking.
PLL loop is closed.
PLL locks.
REFIN (REF1)
REFIN (REF2)
BYPASS
CLK
CLK
LF
REF1
REF2
REGULATOR (LDO)
LOW DROPOUT
VCO
SWITCHOVER
STATUS
REFERENCE
REF_SEL
STATUS
VS
PRESCALER
2, 3, 4, 5, OR 6
P, P + 1
1
DIVIDE BY
Figure 54. Reference and VCO Status Monitors
GND
0
N DIVIDER
DIVIDER
R
COUNTERS
DISTRIBUTION
REFERENCE
A/B
Rev. A | Page 39 of 80
RSET
0
1
PROGRAMMABLE
PROGRAMMABLE
VCO STATUS
R DELAY
N DELAY
REFMON
A sync is executed during the VCO calibration; therefore, the
outputs of the AD9516 are held static during the calibration,
which prevents unwanted frequencies from being produced.
However, at the end of a VCO calibration, the outputs may
resume clocking before the PLL loop is completely settled.
The VCO calibration clock divider is set as shown in Table 54
(Register 0x018[2:1]).
The calibration divider divides the PFD frequency (reference
frequency divided by R) down to the calibration clock. The
calibration occurs at the PFD frequency divided by the
calibration divider setting. Lower VCO calibration clock
frequencies result in longer times for a calibration to be
completed.
The VCO calibration clock frequency is given by
where:
f
R is the value of the R divider.
cal_div is the division set for the VCO calibration divider
(Register 0x018[2:1]).
The VCO calibration takes 4400 calibration clock cycles.
Therefore, the VCO calibration time in PLL reference clock
cycles is given by
Table 29. Example Time to Complete a VCO Calibration
with Different f
f
100
10
10
REFIN
REFIN
f
Time to Calibrate VCO =
4400 × R × cal_div PLL Reference Clock Cycles
(MHz)
is the frequency of the REFIN signal.
CAL_CLOCK
FREQUENCY
DETECTOR
DETECT
= f
PHASE
LOCK
R Divider
1
10
100
REFIN
REFIN
/(R × cal_div)
Frequencies
CPRSET VCP
CHARGE
PUMP
PFD
100 MHz
1 MHz
100 kHz
HOLD
Time to Calibrate VCO
88 μs
8.8 ms
88 ms
LD
CP
STATUS
AD9516-2

Related parts for AD9516-2BCPZ