ADUC842BCPZ32-3 Analog Devices Inc, ADUC842BCPZ32-3 Datasheet - Page 56

Microconverter 1-cycle Version ADUC832

ADUC842BCPZ32-3

Manufacturer Part Number
ADUC842BCPZ32-3
Description
Microconverter 1-cycle Version ADUC832
Manufacturer
Analog Devices Inc
Series
MicroConverter® ADuC8xxr
Datasheets

Specifications of ADUC842BCPZ32-3

Core Processor
8052
Core Size
8-Bit
Speed
8.38MHz
Connectivity
I²C, SPI, UART/USART
Peripherals
DMA, PSM, PWM, Temp Sensor, WDT
Number Of I /o
32
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
2.25K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x12b, D/A 2x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
56-LFCSP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
INTVAL
Function
SFR Address
Power-On Default
Bit Addressable
Valid Value
HTHSEC
Function
SFR Address
Power-On Default
Bit Addressable
Valid Value
SEC
Function
SFR Address
Power-On Default
Bit Addressable
Valid Value
MIN
Function
SFR Address
Power-On Default
Bit Addressable
Valid Value
HOUR
Function
SFR Address
Power-On Default
Bit Addressable
Valid Value
ADuC841/ADuC842/ADuC843
User Time Interval Select Register
User code writes the required time interval to this register. When the 8-bit interval counter is equal to the
time interval value loaded in the INTVAL SFR, the TII bit (TIMECON.2) is set and generates an
interrupt if enabled.
A6H
00H
No
0 to 255 decimal
Hundredths Seconds Time Register
This register is incremented in 1/128 second intervals once TCEN in TIMECON is active. The HTHSEC
SFR counts from 0 to 127 before rolling over to increment the SEC time register.
A2H
00H
No
0 to 127 decimal
Seconds Time Register
This register is incremented in 1-second intervals once TCEN in TIMECON is active. The SEC SFR
counts from 0 to 59 before rolling over to increment the MIN time register.
A3H
00H
No
0 to 59 decimal
Minutes Time Register
This register is incremented in 1-minute intervals once TCEN in TIMECON is active. The MIN SFR
counts from 0 to 59 before rolling over to increment the HOUR time register.
A4H
00H
No
0 to 59 decimal
Hours Time Register
This register is incremented in 1-hour intervals once TCEN in TIMECON is active. The HOUR SFR
counts from 0 to 23 before rolling over to 0.
A5H
00H
No
0 to 23 decimal