ADUM5401CRWZ Analog Devices Inc, ADUM5401CRWZ Datasheet - Page 8

no-image

ADUM5401CRWZ

Manufacturer Part Number
ADUM5401CRWZ
Description
IC,Digital Coupler,SOP,16PIN,PLASTIC
Manufacturer
Analog Devices Inc
Series
IsoPower®, iCoupler®r
Datasheet

Specifications of ADUM5401CRWZ

Design Resources
Fully Isolated Input Module Based on AD7793 and ADuM5401(CN0066) Fully Isolated Input Module Based on AD7793, ADuM5401, and a High Performance In-Amp (CN0067)
Inputs - Side 1/side 2
3/1
Number Of Channels
4
Isolation Rating
2500Vrms
Voltage - Supply
3.3V, 5V
Data Rate
25Mbps
Propagation Delay
45ns
Output Type
Logic
Package / Case
16-SOIC (0.300", 7.5mm Width)
Operating Temperature
-40°C ~ 105°C
Operating Temperature (min)
-40C
Operating Temperature Classification
Industrial
Operating Temperature (max)
105C
Package Type
SOIC W
Rad Hardened
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
EVAL-ADUM540XEBZ - BOARD EVAL FOR ADUM540x
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM5401CRWZ
Manufacturer:
AD
Quantity:
37
Part Number:
ADUM5401CRWZ
Manufacturer:
PHI
Quantity:
34
Part Number:
ADUM5401CRWZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
ADUM5401CRWZ
Quantity:
2 000
Part Number:
ADUM5401CRWZ-RL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADuM5401/ADuM5402/ADuM5403/ADuM5404
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
protective circuits. The asterisk (*) marking on packages denotes DIN V VDE V 0884-10 approval.
Table 6.
Description
Installation Classification per DIN VDE 0110
Climatic Classification
Pollution Degree per DIN VDE 0110, Table 1
Maximum Working Insulation Voltage
Input-to-Output Test Voltage, Method b1
Input-to-Output Test Voltage, Method a
Highest Allowable Overvoltage
Safety Limiting Values
Insulation Resistance at T
RECOMMENDED OPERATING CONDITIONS
Table 7.
Parameter
Operating Temperature
Supply Voltages
Minimum Load
1
2
3
Operation at 105°C requires reduction of the maximum load current, as specified in
All voltages are relative to their respective ground.
If the external load is less than the specified value, the power supply PWM can generate excess switching noise, potentially causing data integrity issues.
V
V
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
After Environmental Tests Subgroup 1
After Input and/or Safety Test Subgroup 2
Case Temperature
Side 1 I
DD1
DD1
and Subgroup 3
@ V
@ V
DD1
SEL
SEL
Current
= 0 V
= V
3
2
ISO
Figure 6. Thermal Derating Curve, Dependence of Safety Limiting Values on Case Temperature, per DIN EN 60747-5-2
1
S
600
500
400
300
200
100
0
0
Conditions
V
partial discharge < 5 pC
V
V
Transient overvoltage, t
Maximum value allowed in the event of a failure
(see Figure 6)
V
IORM
IORM
IORM
IO
= 500 V
× 1.875 = V
× 1.6 = V
× 1.2 = V
50
AMBIENT TEMPERATURE (°C)
Rev. A | Page 8 of 24
PR
PR
Symbol
T
V
V
I
, t
, t
ISO(MIN)
A
PR
DD1
DD1
m
m
, 100% production test, t
= 60 sec, partial discharge < 5 pC
= 60 sec, partial discharge < 5 pC
100
Table 8
TR
= 10 sec
.
150
Min
−40
3.0
4.5
10
m
= 1 sec,
200
Symbol
V
V
V
V
T
I
R
S1
S
IORM
PR
PR
TR
S
Max
+85
3.6
5.5
Characteristic
I to IV
I to III
I to II
40/105/21
2
560
1050
896
672
4000
150
555
>10
9
Unit
°C
V
V
mA
Unit
V peak
V peak
V peak
V peak
V peak
°C
mA
Ω

Related parts for ADUM5401CRWZ