TISP4125M3AJR Bourns Inc., TISP4125M3AJR Datasheet

Sidacs

TISP4125M3AJR

Manufacturer Part Number
TISP4125M3AJR
Description
Sidacs
Manufacturer
Bourns Inc.
Datasheet

Specifications of TISP4125M3AJR

Breakover Current Ibo Max
24 A
Rated Repetitive Off-state Voltage Vdrm
100 V
Off-state Leakage Current @ Vdrm Idrm
0.005 mA
Forward Voltage Drop
3 V
Mounting Style
SMD/SMT
Package / Case
DO-214AC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TISP4125M3AJR-S
Manufacturer:
BOURNS
Quantity:
240 000
Insert xxx value corresponding to protection voltages of 070, 080, 095, etc.
These devices are designed to limit overvoltages on the telephone line. Overvoltages are normally caused by a.c. power system or lightning
flash disturbances which are induced or conducted on to the telephone line. A single device provides 2-point protection and is typically used
for the protection of 2-wire telecommunication equipment (e.g. between the Ring and Tip wires for telephones and modems). Combinations of
devices can be used for multi-point protection (e.g. 3-point protection between Ring, Tip and Ground).
The protector consists of a symmetrical voltage-triggered bidirectional thyristor. Overvoltages are initially clipped by breakdown clamping until
the voltage rises to the breakover level, which causes the device to crowbar into a low-voltage on state. This low-voltage on state causes the
current resulting from the overvoltage to be safely diverted through the device. The high crowbar holding current prevents d.c. latchup as the
diverted current subsides.
4 kV 10/700, 100 A 5/310 ITU-T K.20/21 rating
SMA (DO-214AC) Package
25% Smaller Placement Area than SMB
Low Differential Capacitance ........................................... 39 pF
Ion-Implanted Breakdown Region
Precise and Stable Voltage
Low Voltage Overshoot under Surge
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex
AUGUST 2001 - REVISED JANUARY 2007
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP 4xxxM3AJ AJ (J-Bend DO-214AC/SMA) Embossed Tape Reeled
How To Order
Description
Device
Device
‘4070
‘4080
‘4090
‘4095
‘4115
‘4125
‘4145
‘4165
‘4180
‘4200
‘4220
‘4240
‘4250
‘4265
‘4290
‘4300
‘4320
‘4350
‘4360
‘4395
V
100
120
135
145
155
160
180
190
200
220
230
240
275
290
320
DRM
58
65
68
75
90
V
Package
V
115
125
145
165
180
200
220
240
250
265
290
300
320
350
360
395
70
80
90
95
(BO)
V
TISP4xxxM3AJ Overvoltage Protector Series
Carrier
BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS
TISP4xxxM3AJR-S
Order As
Device Symbol
SMAJ Package (Top View)
Rated for International Surge Wave Shapes
............................................ UL Recognized Components
TISP4070M3AJ THRU TISP4115M3AJ,
TISP4125M3AJ THRU TISP4220M3AJ,
Wave Shape
10/1000 µs
TISP4240M3AJ THRU TISP4395M3AJ
R (B)
10/160 µs
10/700 µs
10/560 µs
T erminals T and R correspond to the
alternative line designators of A and B
2/10 µs
8/20 µs
1
ITU-T K.20/21/45
GR-1089-CORE
GR-1089-CORE
IEC 61000-4-5
R
FCC Part 68
FCC Part 68
T
Standard
SD4XAA
2
MDXXCCE
T (A)
I
220
100
300
120
TSP
75
50
A

Related parts for TISP4125M3AJR

TISP4125M3AJR Summary of contents

Page 1

A 5/310 ITU-T K.20/21 rating SMA (DO-214AC) Package 25% Smaller Placement Area than SMB Low Differential Capacitance ........................................... 39 pF Ion-Implanted Breakdown Region Precise and Stable Voltage Low Voltage Overshoot under Surge V V DRM (BO) ...

Page 2

TISP4xxxM3AJ Overvoltage Protector Series Description (continued) The TISP4xxxM3AJ range consists of twenty voltage variants to meet various maximum system voltage levels ( 320 V). They are guaranteed to voltage limit and withstand the listed international lightning surges in ...

Page 3

TISP4xxxM3AJ Overvoltage Protector Series Electrical Characteristics Parameter Repetitive peak off DRM D DRM state current V Breakover voltage dv/dt = ±250 V/ms, R (BO) dv/dt ≤ ±1000 V/µs, Linear voltage ramp, Impulse ...

Page 4

TISP4xxxM3AJ Overvoltage Protector Series ° Electrical Characteristics Parameter I Off-state current V = ± MHz MHz MHz Off-state capacitance off ...

Page 5

TISP4xxxM3AJ Overvoltage Protector Series Parameter Measurement Information V DRM -v I DRM I (BO) V (BO) Quadrant III Switching Characteristic Figure 1. Voltage-Current Characteristic for T and R Terminals All Measurements are Referenced to the R Terminal AUGUST 2001 - ...

Page 6

TISP4xxxM3AJ Overvoltage Protector Series Typical Characteristics OFF-STATE CURRENT vs JUNCTION TEMPERATURE 100 V = ± 0·1 0·01 0·001 - Junction Temperature - °C J Figure 2. ON-STATE CURRENT vs ON-STATE ...

Page 7

TISP4xxxM3AJ Overvoltage Protector Series Typical Characteristics NORMALIZED CAPACITANCE vs OFF-STATE VOLTAGE 1 0.9 0.8 0.7 0.6 0.5 '4070 THRU '4115 0.4 '4125 THRU '4200 0.3 '4240 THRU '4395 0.2 0 Off-state Voltage - ...

Page 8

TISP4xxxM3AJ Overvoltage Protector Series Rating and Thermal Information NON-REPETITIVE PEAK ON-STATE CURRENT V DERATING FACTOR DRM vs MINIMUM AMBIENT TEMPERATURE 1.00 0.99 '4125 THRU '4200 0.98 0.97 0.96 0.95 '4070 THRU '4115 0.94 '4240 THRU '4395 0.93 -40 -35 -30 ...

Page 9

TISP4xxxM3AJ Overvoltage Protector Series Deployment These devices are two terminal overvoltage protectors. They may be used either singly to limit the voltage between two conductors (Figure 12 multiples to limit the voltage at several points in a circuit ...

Page 10

TISP4xxxM3AJ Overvoltage Protector Series AC Power Testing The protector can withstand currents applied for times not exceeding those shown in Figure 9. Currents that exceed these times must be terminated or reduced to avoid protector failure. Fuses, PTC (Positive Temperature ...

Page 11

TISP4xxxM3AJ Overvoltage Protector Series Typical Circuits RING FUSE TISP4350 TIP Figure 14. Modem Inter-Wire Protection OVER- RING/TEST CURRENT PROTECTION PROTECTION TIP WIRE R1a Th1 R1b RING WIRE AUGUST 2001 - REVISED JANUARY 2007 Specifications are subject to change without notice. ...

Page 12

TISP4xxxM3AJ Overvoltage Protector Series Recommended Printed Wiring Footprint SMA Land Pattern MILLIMETERS DIMENSIONS ARE: (INCHES) Device Symbolization Code Devices will be coded as below. As the device parameters are symmetrical, terminal 1 is not identified. Carrier Information For production quantities, ...

Related keywords