G2R-1A-E-AC120 Omron, G2R-1A-E-AC120 Datasheet - Page 6

RELAY

G2R-1A-E-AC120

Manufacturer Part Number
G2R-1A-E-AC120
Description
RELAY
Manufacturer
Omron
Series
G2Rr
Datasheets

Specifications of G2R-1A-E-AC120

Relay Type
General Purpose
Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
16A
Switching Voltage
380VAC, 125VDC - Max
Coil Type
Standard
Coil Current
7.5mA
Coil Voltage
120VAC
Turn On Voltage (max)
96 VAC
Turn Off Voltage (min)
36 VAC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPST-NO (1 Form A)
Contact Rating @ Voltage
16A @ 250VAC
Control On Voltage (max)
96 VAC
Control Off Voltage (min)
36 VAC
Contact Rating
16 A
Contact Termination
Solder Pin
Mounting Style
Through Hole
Power Consumption
0.9 VA
Contact Material
Silver Alloy
Coil Resistance
6.5 K Ohms
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G2R-1A-E-AC120
G2R1AEAC120
Z2310

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G2R-1A-E-AC120
Manufacturer:
ASTEC
Quantity:
200
Glossary
■ Terms Related to Contacts
Carry Current
The value of the current which can be continuously applied to the
relay contacts without opening or closing them, and which allows the
relay to stay within the permissible temperature rise.
Maximum Switching Current
A current which serves as a reference in determining the perfor-
mance of the relay contacts. This value will never exceed the current
flow. When using a relay, do not exceed this value.
Contact Form
OMRON uses the following relay terminology for the various polarity
and switch configurations.
1 FORM A: SPST-NO
1 FORM B: SPST-NC
1 FORM C: SPDT
2 FORM C: DPDT
Make-before-break (MBB) Contact
A contact arrangement in which part of the switching section is
shared between both an NO and NC contact. When the relay oper-
ates or releases, the contact that closes the circuit operates before
the contact that opens the circuit releases. Thus both contacts are
closed momentarily at the same time.
6
Contact symbols
Double-break
Make-before-break
NO
Electromechanical Relays
NC
Latching relays
NC
DT
Technical Information
Contact Resistance
The total resistance of the conductor, as well as specific resistivities
such as of the armature and terminal, and the resistance of the con-
tacts. Contact resistance values given in this catalog are initial val-
ues. These values are not intended to indicate suitability or
unsuitability in actual use. The contact resistance values given are
measurement values for a stable contact circuit at a stable contact
resistance. This value is determined by measuring the voltage drop
across the contacts by applying test currents as shown in the table
below.
For most applications, use at least 1 A, 5 VDC for contact resistance
measurements.
Maximum Switching Capacity
The maximum value of the load capacity which can be switched with-
out problem. When using a relay, do not exceed this value.
For example, when maximum switching voltage V
mum switching current I
on the characteristic curve “Maximum Switching Capacity” shown
below. Conversely, maximum switching voltage V
I
Under 0.01
0.01 to 0.1
0.1 to 1
Over 1
1
is known.
Maximum switching current (I
Maximum switching voltage (V
For instance, if the maximum switching voltage = 40 V
Maximum switching current = 2 A (see circled point on graph
below.)
Rated current (A)
1
can be obtained at the point of intersection
Switching voltage (V)
1
) =
1
) =
1
10
100
1000
Max. switching power [W(VA)]
Max. switching power [W(VA)]
Max. switching voltage (V1)
Max. switching current (I1)
Test current (mA)
1
can be obtained if
1
is known, maxi-

Related parts for G2R-1A-E-AC120