G4A-1A-PE-T130 DC12

Manufacturer Part NumberG4A-1A-PE-T130 DC12
DescriptionPower PCB Relay
ManufacturerOmron
SeriesG4A
G4A-1A-PE-T130 DC12 datasheet
 


Specifications of G4A-1A-PE-T130 DC12

Relay TypeGeneral PurposeContact FormSPST-NO (1 Form A)
Contact Rating (current)20ASwitching Voltage250VAC - Max
Coil TypeStandardCoil Current75mA
Coil Voltage12VDCTurn On Voltage (max)8.4 VDC
Turn Off Voltage (min)1.2 VDCMounting TypeThrough Hole
Termination StylePC PinCircuitSPST-NO (1 Form A)
Contact Rating @ Voltage20A @ 250VACControl On Voltage (max)8.4 VDC
Control Off Voltage (min)1.2 VDCLead Free Status / RoHS StatusLead free / RoHS Compliant
Other namesG4A-1A-PE-T130DC12
G4A-1A-PE-T130DC12BYOMZ(C)
G4A-1A-PE-T130DC12BYOMZ(C)
G4A1APET130DC12
  
1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
6
Page 6
Page 1/6

Download datasheet (500Kb)Embed
Next
Power PCB Relay
G4A
Miniature Single-pole Relay with 80-A Surge
Current and 20-A Switching Current
• Ideal for motor switching.
• Miniature, relay with high switching power and long
endurance.
• Creepage distance conforms to UL and CSA standards.
• Highly noise-resistive insulation materials employed.
• Standard model available with flux protection construction.
• RoHS Compliant
Ordering Information
Classification
#250 tab terminals/PCB coil terminals
PCB terminals/PCB coil terminals
Note: When ordering, add the rated coil voltage to the model number.
Example: G4A-1A-E DC12
Rated coil voltage
Model Number Legend
G4A
-
DC
1
2
3
4
5
3. Terminals
1. Number of Poles
1: 1 Pole
None: #250 tab/PCB coil terminals
P:
Straight PCB/PCB coil terminals
2. Contact Form
4. Special Function
A: SPST-NO
E:
For long endurance
Specifications
■ Contact Ratings
Rated load
20 A at 250 VAC
Rated carry current
20 A
Max. switching voltage
250 VAC
Max. switching current
20 A
Max. switching capacity
5,000 VA
Min. Permissible Load
100 mA at 5 VDC
(reference value - see note)
λ
-6
Note: P level:
= 0.1 x 10
/operation
60
Contact form
SPST-NO
5. Rated Coil Voltage
5, 12, 24 VDC
X
C
R
VDE
Model
G4A-1A-E
G4A-1A-PE
G4A
221
Power PCB Relay

G4A-1A-PE-T130 DC12 Summary of contents

  • Page 1

    ... Standard model available with flux protection construction. • RoHS Compliant Ordering Information Classification #250 tab terminals/PCB coil terminals PCB terminals/PCB coil terminals Note: When ordering, add the rated coil voltage to the model number. Example: G4A-1A-E DC12 Rated coil voltage Model Number Legend G4A - DC 1 ...

  • Page 2

    ... Mechanical: Motor load: Inverter load: Operating: −20°C to 60°C (with no icing) Ambient temperature Ambient humidity Operating 85% Weight Approx Note: The data shown above are initial values. G4A 222 Power PCB Relay 12 VDC 75 mA 160 Ω 0.8 H 1.1 H Switching frequency ON:1.5 s OFF:1 ...

  • Page 3

    ... Mounting Holes (Bottom View) +0.1 Four, 1.8 dia. 0 Terminal Arrangement /Internal Connections (Top View) (Bottom View) Tab Terminal PCB Terminal Mounting Holes (Bottom View) +0.1 Four, 1.8 dia. 0 Terminal Arrangement /Internal Connections (Bottom View) G4A 223 Power PCB Relay ...

  • Page 4

    ... Do not apply excessive force on the terminals when mounting or dismounting the relay. The following positive-lock connectors made by AMP are recommended. Type #250 terminals (width: 6.35 mm) Note: The numbers shown in parentheses are for air-feeding. G4A 224 Power PCB Relay Receptacle terminals AMP 170333-1 (170327-1) ...

  • Page 5

    ... Amendment: These Terms constitute the entire agreement between Buyer and Seller relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. 5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. Power PCB Relay G4A ...

  • Page 6

    ... E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 06/09 Cat. No. X301-E-1 G4A Power PCB Relay 2. Programmable Products. Seller shall not be responsible for the user's pro- gramming of a programmable product, or any consequence thereof. 3. Performance Data. Performance data given in this publication is provided as a guide for the user in determining suitability and does not constitute a war- ranty ...