G7L-2A-BUBJ-CB-IN DC24 BY OMI Omron, G7L-2A-BUBJ-CB-IN DC24 BY OMI Datasheet - Page 12

no-image

G7L-2A-BUBJ-CB-IN DC24 BY OMI

Manufacturer Part Number
G7L-2A-BUBJ-CB-IN DC24 BY OMI
Description
GP Power Relay
Manufacturer
Omron
Series
G7Lr
Datasheet

Specifications of G7L-2A-BUBJ-CB-IN DC24 BY OMI

Relay Type
General Purpose
Contact Form
DPST (2 Form A)
Contact Rating (current)
25A
Switching Voltage
250VAC - Max
Coil Type
Standard
Coil Current
79mA
Coil Voltage
24VDC
Turn On Voltage (max)
18 VDC
Turn Off Voltage (min)
3.6 VDC
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Circuit
DPST (2 Form A)
Contact Rating @ Voltage
25A @ 220VAC
Control On Voltage (max)
18 VDC
Control Off Voltage (min)
3.6 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G7L-2A-BUBJ-CB-INDC24BYOMI
G7L2ABUBJCBINDC24BYOMI
Precautions
■ Handling
• To preserve initial performance, do not drop or otherwise subject
• The case is not designed to be removed during normal handling
• Use the power relay in a dry environment free from excessive dust,
• Do not allow a voltage greater than the maximum allowable coil
• Do not use the power relay outside of specified voltages and cur-
• Do not allow the ambient operating temperature to exceed the
■ Installation
• Although there are not specific limits on the installation site, it
• PCB terminal-equipped relays weigh approximately 100 g. Be sure
• Quick-connect terminals can be connected to fast on receptacle
• Allow suitable slack on leads when wiring, and do not subject the
■ Cleaning PCB Terminals
• PCB terminals have semi-sealed construction which prevents flux
■ Applications
• Compressors for package air conditioners and heater switching
• Switching controllers for power tools or motors
• Power controllers for water heaters
• Power controllers for dryers
• Lamp control, motor drivers, and power supply switching in copy
• Lighting controllers
• Power controllers for packers or food processing equipment
• Magnetron control in microwaves
316
the power relay to shock.
and operation. Doing so may affect performance.
SO
voltage to be applied continuously.
rents.
specified limit.
should be as dry and dust-free as possible.
that the PCB is strong enough to support them. We recommend
dual-side through-hole PCBs to reduce solder cracking from heat
stress.
#250 and positive-lock connectors.
terminals to excessive force.
from entering the relay base. It is recommended that the user
should apply a tape seal over the vent hole prior to wave soldering
or cleaning. The tape should then be removed after processing.
controllers
machines, facsimiles, and other OA equipment
2
, H
2
S, or organic gas.
General Purpose Relay
G7L
■ Operating Coil
• As a rule, either a battery or a DC power supply with a maximum
• When driving a transistor, check the leakage current and connect a
• Momentary voltage drops on coil input voltage should not exceed
5% ripple is used for the operating voltage for DC relays. Before
using a rectified AC supply, confirm that the ripple is not greater
than 5%. Ripple greater than this can lead to variations in the oper-
ating and reset voltages.
bleeder resistor if necessary.
one second duration after contact mating with no shock or vibra-
tion.
As excessive ripple can generate beats, the insertion of a
smoothing capacitor is recommended as shown below.

Related parts for G7L-2A-BUBJ-CB-IN DC24 BY OMI