S82Y-D30S Omron, S82Y-D30S Datasheet - Page 3

no-image

S82Y-D30S

Manufacturer Part Number
S82Y-D30S
Description
S82D-300w SIDE BRACKET
Manufacturer
Omron
Series
S82Dr
Datasheets

Specifications of S82Y-D30S

Accessory Type
Mounting Bracket(s)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
S82D-30xx Power Supply
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S82YD30S
Specifications Table
Note: Be sure to remove short bar attached between FC and ACG terminals before performing dielectric strength test or insulation resis-
Engineering Data
J DERATING CURVE
Note: The derating curve differs depending on the mounting
Power rating
Characteristics
Ambient temperature
Ambient temperature
Ambient humidity
Ambient humidity
Dielectric strength (see note below table)
Insulation resistance (see note below table)
Vibration resistance
Shock resistance
Output indicator
Electromagnetic interference
Approved standards
Weight
tance test because surge absorber is connected across input lines.
position of the power supply. The curve above was ob-
tained with the power supply mounted in the standard
position.
Ambient temperature _C
– continued from previous page
Operating
Storage
Operating
Storage
300 W
See the derating curve in the Engineering Data section
–25°C to 85°C (–13°F to 185°F)
25% to 85%
25% to 95%
2000 VAC, 50/60Hz for 1 min (between all inputs and outputs/housing)
500 VDC for 1 min (between all inputs and outputs/housing)
100 MΩ min. at 500 VDC (between all outputs and inputs/housing)
Malfunction: 10 to 55 Hz, 0.75-mm double amplitude (approx. 4.5G) each in X, Y,
and Z directions for 2 hours.
Malfunction: 294 m/s
Yes (red)
Meets FCC class A standards
UL 1012, CSA E.B. 1402
2.5 kg max.
J OVERVOLTAGE PROTECTION
The protective function prevents damage to the load and to the
power supply itself (from overvoltage). The output is shut off if the
output voltage rises above about 120% of the rated voltage. The
input power must be turned off for at least 30 s. Then, turn it on
again to reset the power supply.
2
(30G), 3 times each in ±1X, ±1Y, and ±1Z directions
Rated output
voltage
Switching Power Supply
Approx.
20%
10%
–10%
600 W
4 kg max.
Variable
Overvoltage
S82D
3

Related parts for S82Y-D30S